  1. Experimental Testing of Axially Loaded Fuse Plates Without Continuous Buckling Restraint

    … connections address this issue with replaceable fuse plate connections. These fuse plate connections move the plastic hinge out of the beam and into the replaceable fuse, allowing for more economical and faster repairs following a seismic event. This thesis explores two different fuse plate …

    byu Repository record for Experimental Testing of Axially Loaded Fuse Plates Without Continuous Buckling Restraint (opens in a new tab)

  2. Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates

    … that employs replaceable buckling-restrained fuse plates that can enhance seismic performance and post-earthquake repairability. A total of eight unique specimens were tested on two series of beam-to-column subassemblies (W36 and W24) to investigate connection behavior under cyclic loading. …

    byu Repository record for Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates (opens in a new tab)

  3. Experimental Evaluation of Replaceable Shear Fuse Moment Connections

    … a new connection called the Replaceable Shear Fuse (RSF) connection. The RSF connection uses shear-yielding fuse plates to prevent beam and column yielding. A total of 7 test specimens with varying fuse plate sizes and configurations, a W14×48 column, and a W14×38 beam were created. The …