Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 51 for “"gamma analysis"”

  1. Assessment of Uncertainty In Planning and Dose Delivery of Proton Therapy In An Iroc- Houston Qa Phantom Due to Variable Ct Technique and Proton Energy

    … the percent of passing pixels by 10% using a gamma analysis criteria of ±3%/5mm as measured using a heterogeneous proton QA phantom. A CT phantom used by IROC-H during therapy site visits was scanned using three CT techniques (80, 120, 140kV) with a CT scanner used for proton therapy …

    uthsc Repository record for Assessment of Uncertainty In Planning and Dose Delivery of Proton Therapy In An Iroc- Houston Qa Phantom Due to Variable Ct Technique and Proton Energy (opens in a new tab)

  2. Dose Prediction for Radiotherapy of Advanced Stage Lung Cancer

    … size of 4. The predicted dose was rescaled for gamma analysis to quantify accuracy of the model. The renormalized predicted dose was quantified using gamma analysis with a 3mm, 3% dose tolerance. The gamma map was generated to visualize the regions where dose distributions failed. The gamma …

    mcmaster Repository record for Dose Prediction for Radiotherapy of Advanced Stage Lung Cancer (opens in a new tab)

  3. Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging

    … planning system (TPS) by pixel-wise comparison, gamma analysis, and a novel approach of morphological connected component analysis. Tests with off-reference values of phantom thickness, field size, and monitor units showed good agreement, with the great majority of points within ±3% of TPS dose. …

    calgary Repository record for Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging (opens in a new tab)

  4. Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom

    … dose difference and 4 mm distance-to-agreement. Gamma analysis was used to assess dosimetric accuracy, as well. All treatment plans were able to meet the dosimetric objectives set by the RPC and had similar hot spots in the normal tissue. The Elekta VMAT plan was more homogenous but less …

    uthsc Repository record for Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom (opens in a new tab)

  5. Credit Cards: Average Monthly Unpaid Balance as Related to Certain Socio-Economic Factors

    … tests used were the chi square and the gamma analysis. It was found that the six variables tested had no significant relationship upon the amount of the average monthly unpaid credit card balance.

    utahstate Repository record for Credit Cards: Average Monthly Unpaid Balance as Related to Certain Socio-Economic Factors (opens in a new tab)

  6. Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision

    … framework examined dose agreement through gamma analysis, dose-volume histogram comparisons, and structure-based endpoints such as D95, and examined image agreement through Hounsfield-unit mean absolute error, pixel-wise fidelity, structural similarity index measure, difference …

    vcu Repository record for Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision (opens in a new tab)

  7. Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters

    … with 2D measurements within ±5%/3mm using a gamma index analysis. The PRESAGE® dosimeter will detect dose discrepancies not detected with 2D measurements resulting in a 5% change in the normal tissue complication probability (NTCP). An optical CT scanner was tested for reproducibility and …

    uthsc Repository record for Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters (opens in a new tab)

  8. Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry

    … CBCT using signal-to-noise ratio (SNR) and gamma analysis and (2) establishing the feasibility of using deformable gel dosimeters to evaluate dose deformation on Ethos using gamma pass rate (GPR). It was found that Ethos’s SNR was up to 40% lower than TrueBeam, using stationary PGDs. The …

    ubc Repository record for Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry (opens in a new tab)

  9. Analysis of cyclic shallow-water carbonates: Cambrian Highland Peak Formation, eastern Nevada

    Several methods of analysis were used to test the robustness of sea level signals recorded in Middle to lower Upper Cambrian shallow-water carbonate rocks in the southwestern United States and to refine stratigraphic correlation of this interval. Embedded Markov chain and cycle architectural …

    unlv Repository record for Analysis of cyclic shallow-water carbonates: Cambrian Highland Peak Formation, eastern Nevada (opens in a new tab)

  10. Validation of a Monte Carlo dose calculation algorithm for clinical electron beams in the presence of phantoms with complex heterogeneities

    … better with the film measurements based on gamma analysis. Gamma values for eMC were between 83%-99%, whereas gamma values for PB treatment plans were as low as 38.66%. Our results show that using the eMC algorithm will improve dose accuracy in regions with heterogeneities and should be …

    fau Repository record for Validation of a Monte Carlo dose calculation algorithm for clinical electron beams in the presence of phantoms with complex heterogeneities (opens in a new tab)

  11. Automated multi-radionuclide separation and analysis with combined detection capability

    … of detection instruments. Flow scintillation analysis is used for ⁹⁰Sr and ²¹⁰Po determination, flow gamma analysis is used assess ⁶⁰Co and ¹³⁷Cs, and inductively coupled plasma mass spectrometry is used to determine actinides. Detection limits for these analytes were determined for the …

    texas Repository record for Automated multi-radionuclide separation and analysis with combined detection capability (opens in a new tab)

  12. A Dosimetric Evaluation of The Eclipse and Pinnacle Treatment Planning Systems in Treatment of Vertebral Bodies Using IMRT and VMAT with Modeled and Commissioned Flattening Filter Free (FFF) Fields.

    … linear accelerator, to a 4D QA phantom for a gamma analysis and distance to agreement (DTA) comparison. All Eclipse calculations were made for both measured and optimized DLG parameters.Calculated vs. measured point dose for the Pinnacle TPS had an average difference of 2.79 +/- 2.00%. Gamma …

    ohiolink Repository record for A Dosimetric Evaluation of The Eclipse and Pinnacle Treatment Planning Systems in Treatment of Vertebral Bodies Using IMRT and VMAT with Modeled and Commissioned Flattening Filter Free (FFF) Fields. (opens in a new tab)

  13. Open source software development for radiochromic film dosimetry analysis

    … flexible, and open-source software for film analysis limits its broader adoption in clinical and research settings. This work presents FilmQADose, a free and open source software platform for the calibration, reconstruction, and analysis of dose distributions from irradiated Gafchromic EBT3 …

    uniandes Repository record for Open source software development for radiochromic film dosimetry analysis (opens in a new tab) Embargoed

  14. Milankovitch Paleoclimatic Signals in Upper Permian–Lower Triassic Fluvial-Lacustrine Records, Bogda Mountains, Greater Turpan-Junggar Intracontinental Rift Basin, NW China

    … Region, NW China. This study carried out gamma analysis, gamma and astronomical tuning, and spectral analysis on the Wutonggou, Jiucaiyuan, and Shaofanggou low-order cycles of the South and Central Taodonggou, South and North Tarlong, Dalongkou, and Zhaobishan sections. Stable and positive …

    must-thes Repository record for Milankovitch Paleoclimatic Signals in Upper Permian–Lower Triassic Fluvial-Lacustrine Records, Bogda Mountains, Greater Turpan-Junggar Intracontinental Rift Basin, NW China (opens in a new tab)

  15. Electron Monte Carlo Dose Calculation Model Dependency on Optional Applicator Specific 1D Profiles

    … for all energy and applicator combinations using gamma analysis. The greatest differences in passing rates and average gamma for the CP and IP profile comparisons corresponded to the IP profiles due to the without optional algorithm having zero data on the electron fluence in the IP. Clinical …

    unlv Repository record for Electron Monte Carlo Dose Calculation Model Dependency on Optional Applicator Specific 1D Profiles (opens in a new tab)

  16. Monte Carlo simulation and dosimetric studies for small fields in lung stereotactic body radiation therapy

    … parameters for accurate MC simulation. Electron Gamma Shower Monte Carlo Simulation Package developed by the Ionizing Radiation Standards Group at National Research Council of Canada (EGSnrc) will be used as the MC code. Field-size specific MC simulated doses of a 6 MV photon beam were validated …

    nanyang Repository record for Monte Carlo simulation and dosimetric studies for small fields in lung stereotactic body radiation therapy (opens in a new tab)

  17. Comparison of Commercial Pre-Treatment QA Devices for Stereotactic Radiotherapy Plans

    … commercial devices QA data were analyzed using gamma analysis criteria of 3%/3mm DTA, 2%/2mm DTA, 2%/1mm DTA, and 1%/1 mm DTA using the device's software. The results of the commercial devices are compared to the EBT-XD film dosimetry results for each gamma criteria. Treatment plan …

    gatech Repository record for Comparison of Commercial Pre-Treatment QA Devices for Stereotactic Radiotherapy Plans (opens in a new tab)

  18. Commissioning An Anthropomorphic Spine and Lung Phantom For Remote Dose Verification of Institutions Participating In Rtog 0631

    … dose profiles, isodose distributions, and gamma analyses. Based on previous experience at the RPC, a gamma analysis was considering passing if greater than 95% of pixels passed the criteria of 5% dose difference and 3 mm distance-to-agreement. Each irradiation showed acceptable agreement in …

    uthsc Repository record for Commissioning An Anthropomorphic Spine and Lung Phantom For Remote Dose Verification of Institutions Participating In Rtog 0631 (opens in a new tab)

  19. Development and Implementation of An Anthropomorphic Pediatric Spine Phantom For The Assessment of Craniospinal Irradiation Procedures In Proton Therapy

    … 5%/3mm, with 85% of pixels passing criteria for gamma analysis and also a TLD point dose agreement within 5%. Tissue equivalency was determined by measuring the relative stopping power and Hounsfield unit of potential phantom materials. The materials selected as bone, tissue, and cartilage …

    uthsc Repository record for Development and Implementation of An Anthropomorphic Pediatric Spine Phantom For The Assessment of Craniospinal Irradiation Procedures In Proton Therapy (opens in a new tab)

Page 1 of 3