Assessment of Uncertainty In Planning and Dose Delivery of Proton Therapy In An Iroc- Houston Qa Phantom Due to Variable Ct Technique and Proton Energy
… the percent of passing pixels by 10% using a gamma analysis criteria of ±3%/5mm as measured using a heterogeneous proton QA phantom. A CT phantom used by IROC-H during therapy site visits was scanned using three CT techniques (80, 120, 140kV) with a CT scanner used for proton therapy …
-
Dose Prediction for Radiotherapy of Advanced Stage Lung Cancer
… size of 4. The predicted dose was rescaled for gamma analysis to quantify accuracy of the model. The renormalized predicted dose was quantified using gamma analysis with a 3mm, 3% dose tolerance. The gamma map was generated to visualize the regions where dose distributions failed. The gamma …
-
Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging
… planning system (TPS) by pixel-wise comparison, gamma analysis, and a novel approach of morphological connected component analysis. Tests with off-reference values of phantom thickness, field size, and monitor units showed good agreement, with the great majority of points within ±3% of TPS dose. …
-
Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom
… dose difference and 4 mm distance-to-agreement. Gamma analysis was used to assess dosimetric accuracy, as well. All treatment plans were able to meet the dosimetric objectives set by the RPC and had similar hot spots in the normal tissue. The Elekta VMAT plan was more homogenous but less …
-
Credit Cards: Average Monthly Unpaid Balance as Related to Certain Socio-Economic Factors
… tests used were the chi square and the gamma analysis. It was found that the six variables tested had no significant relationship upon the amount of the average monthly unpaid credit card balance.
-
Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision
… framework examined dose agreement through gamma analysis, dose-volume histogram comparisons, and structure-based endpoints such as D95, and examined image agreement through Hounsfield-unit mean absolute error, pixel-wise fidelity, structural similarity index measure, difference …
-
Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters
… with 2D measurements within ±5%/3mm using a gamma index analysis. The PRESAGE® dosimeter will detect dose discrepancies not detected with 2D measurements resulting in a 5% change in the normal tissue complication probability (NTCP). An optical CT scanner was tested for reproducibility and …
-
Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry
… CBCT using signal-to-noise ratio (SNR) and gamma analysis and (2) establishing the feasibility of using deformable gel dosimeters to evaluate dose deformation on Ethos using gamma pass rate (GPR). It was found that Ethos’s SNR was up to 40% lower than TrueBeam, using stationary PGDs. The …
-
Analysis of cyclic shallow-water carbonates: Cambrian Highland Peak Formation, eastern Nevada
Several methods of analysis were used to test the robustness of sea level signals recorded in Middle to lower Upper Cambrian shallow-water carbonate rocks in the southwestern United States and to refine stratigraphic correlation of this interval. Embedded Markov chain and cycle architectural …
-
A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-d diode array
… posterior) and planned gantry angle delivery. A gamma analysis has been performed for all beam arrangements. The measurements were obtained using the 2-D diode array MapCHECK 2™.
-
Validation of a Monte Carlo dose calculation algorithm for clinical electron beams in the presence of phantoms with complex heterogeneities
… better with the film measurements based on gamma analysis. Gamma values for eMC were between 83%-99%, whereas gamma values for PB treatment plans were as low as 38.66%. Our results show that using the eMC algorithm will improve dose accuracy in regions with heterogeneities and should be …
-
Automated multi-radionuclide separation and analysis with combined detection capability
… of detection instruments. Flow scintillation analysis is used for ⁹⁰Sr and ²¹⁰Po determination, flow gamma analysis is used assess ⁶⁰Co and ¹³⁷Cs, and inductively coupled plasma mass spectrometry is used to determine actinides. Detection limits for these analytes were determined for the …
-
A Dosimetric Evaluation of The Eclipse and Pinnacle Treatment Planning Systems in Treatment of Vertebral Bodies Using IMRT and VMAT with Modeled and Commissioned Flattening Filter Free (FFF) Fields.
… linear accelerator, to a 4D QA phantom for a gamma analysis and distance to agreement (DTA) comparison. All Eclipse calculations were made for both measured and optimized DLG parameters.Calculated vs. measured point dose for the Pinnacle TPS had an average difference of 2.79 +/- 2.00%. Gamma …
-
Open source software development for radiochromic film dosimetry analysis
… flexible, and open-source software for film analysis limits its broader adoption in clinical and research settings. This work presents FilmQADose, a free and open source software platform for the calibration, reconstruction, and analysis of dose distributions from irradiated Gafchromic EBT3 …
-
Milankovitch Paleoclimatic Signals in Upper Permian–Lower Triassic Fluvial-Lacustrine Records, Bogda Mountains, Greater Turpan-Junggar Intracontinental Rift Basin, NW China
… Region, NW China. This study carried out gamma analysis, gamma and astronomical tuning, and spectral analysis on the Wutonggou, Jiucaiyuan, and Shaofanggou low-order cycles of the South and Central Taodonggou, South and North Tarlong, Dalongkou, and Zhaobishan sections. Stable and positive …
-
Electron Monte Carlo Dose Calculation Model Dependency on Optional Applicator Specific 1D Profiles
… for all energy and applicator combinations using gamma analysis. The greatest differences in passing rates and average gamma for the CP and IP profile comparisons corresponded to the IP profiles due to the without optional algorithm having zero data on the electron fluence in the IP. Clinical …
-
Monte Carlo simulation and dosimetric studies for small fields in lung stereotactic body radiation therapy
… parameters for accurate MC simulation. Electron Gamma Shower Monte Carlo Simulation Package developed by the Ionizing Radiation Standards Group at National Research Council of Canada (EGSnrc) will be used as the MC code. Field-size specific MC simulated doses of a 6 MV photon beam were validated …
-
Comparison of Commercial Pre-Treatment QA Devices for Stereotactic Radiotherapy Plans
… commercial devices QA data were analyzed using gamma analysis criteria of 3%/3mm DTA, 2%/2mm DTA, 2%/1mm DTA, and 1%/1 mm DTA using the device's software. The results of the commercial devices are compared to the EBT-XD film dosimetry results for each gamma criteria. Treatment plan …
-
Commissioning An Anthropomorphic Spine and Lung Phantom For Remote Dose Verification of Institutions Participating In Rtog 0631
… dose profiles, isodose distributions, and gamma analyses. Based on previous experience at the RPC, a gamma analysis was considering passing if greater than 95% of pixels passed the criteria of 5% dose difference and 3 mm distance-to-agreement. Each irradiation showed acceptable agreement in …
-
Development and Implementation of An Anthropomorphic Pediatric Spine Phantom For The Assessment of Craniospinal Irradiation Procedures In Proton Therapy
… 5%/3mm, with 85% of pixels passing criteria for gamma analysis and also a TLD point dose agreement within 5%. Tissue equivalency was determined by measuring the relative stopping power and Hounsfield unit of potential phantom materials. The materials selected as bone, tissue, and cartilage …