Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 34 for “"gamma index"”.
-
Validation of radiation treatment planning with a pseudo-CT derived from MR images
… and monitor units. Dose point calculation and gamma index was used to access the dose accuracy. The point dose calculation agreement and the percentage of points passing the gamma index are excellent for the pseudo-CT and bulk methods with very minimal difference compared to the reference CT. …
-
New approaches to improving the accuracy and outcome of Intensity Modulated Radiotherapy
… differ. A new method of calculating the popular Gamma index is proposed, along with a new Kappa index which can highlight areas of dose mismatch more readily than the Gamma index. Using a specially developed dose calculation system, systematic errors found with the IMRT treatment machines at …
-
Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator
… and compared with MC simulations. The standard gamma index method with AAPM TG 53 recommendations are used to benchmark the measurements (radio chromic film) against planar dose (Monte Carlo simulation) along with isodose lines and profiles in both homogeneous and heterogeneous mediums. The …
-
Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters
… with 2D measurements within ±5%/3mm using a gamma index analysis. The PRESAGE® dosimeter will detect dose discrepancies not detected with 2D measurements resulting in a 5% change in the normal tissue complication probability (NTCP). An optical CT scanner was tested for reproducibility and …
-
Evaluation of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due to Imrt Treatment Plan Complexity and Improperly Matched Dosimetry Data
… 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in …
-
Σχεδιασμός πλάνων θεραπείας με τεχνικές 3D-CRT και VMAT και μελέτη επιβεβαίωσης των πλάνων με δυο ανεξάρτητες δοσιμετρικές μεθόδους
… των δυο κατανομών έγινε η χρήση της μεθόδου Gamma- Index. Με κριτήρια αποδοχής 3mm και 3%, οι ποσοστιαίες διαφορές μεταξύ των δύο κατανομών βρέθηκαν μικρότερες από 7% για το Delta4 ενώ για τα ομοιώματα δοσιμετρίας γέλης πολυμερισμού, με κριτήρια αποδοχής 2mm και 3%, οι ποσοστιαίες διαφορές …
-
Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device
… with calculated doses from TPS at the exit. The gamma index at 3% dose difference (DD) and 3mm distance to agreement (DTA) resulted in an average of 97% acceptance for the square fields of 5, 10, 15 and 20 cm thickness solid water homogeneous phantoms. More than 90% of all points passed the gamma …
-
Human Footpaths in the Outer Suburbs of Ottawa: Distribution, Network Connectivity, and Walkability
… is measured using the link-node ratio, the gamma index, and the alpha index, as well a node betweenness centrality. Walkability is measured in ArcGIS through an origin-destination cost matrix. The results show that the distribution of footpaths cannot be explained by the selected variables. …
-
Μελέτη και ανάπτυξη μεθόδων δοσιμετρικής επαλήθευσης πλάνων θεραπείας σε σύγχρονες τεχνικές ακτινοθεραπείας
… way. The ISD method was compared to the gamma index using intentionally erroneous VMAT and IMRT plans. Results revealed that the ISD method is sensitive to all errors induced in the plans. Discrepancies are presented per isodose, enabling the evaluation of the plan in two regions, which …
-
Avaliação do movimento respiratório em radioterapia utilizando simulação Monte Carlo
… the results of the dose profiles using the gamma index with criteria of 3% / 3mm.The experimental measurements were performed using radiochromic films with the phantom static, in motion and with the phantom in motion and the triggering of the beam. For the simulation with Monte Carlo method, …
-
On the Development of Computational Methods to Help in Performing Medical Physics Tasks Leveragin the Portal Dosimetry Application
… images and reduce the QA time when performing gamma analysis at varying test criteria and evaluating the results of the Winston-Lutz test. The application leverages the Eclipse Scripting API (ESAPI) within the Eclipse Treatment planning system of Varian Medical Systems. The Portal Dosimetry …
-
Structure development in fiber formation of nylon-6
… in higher crystallinity. A sample with a high γ content can be produced directly by melt spinning at high speeds. The total crystallinity and the different crystalline fractions have been analyzed by means of a new γ index.</p><p>It is observed that the c-axis crystalline orientation …
-
COUPLING BIOPHYSICAL COMPLEXITY AND FOREST METABOLISM IN A FLOODPLAIN LANDSCAPE
… ground height, vegetative structural diversity index, mean flow length, mean flow accumulation, mean percent inundation, and gamma index metrics computed from Light Detection and Ranging (LiDAR) data, HEC-RAS inundation modeling, and ArcGIS Arc Hydro derived metrics. Potential primary production …
-
COUPLING BIOPHYSICAL COMPLEXITY AND FOREST METABOLISM IN A FLOODPLAIN LANDSCAPE
… ground height, vegetative structural diversity index, mean flow length, mean flow accumulation, mean percent inundation, and gamma index metrics computed from Light Detection and Ranging (LiDAR) data, HEC-RAS inundation modeling, and ArcGIS Arc Hydro derived metrics. Potential primary production …
-
Combining Monte Carlo simulations and detector measurements for a novel quality assurance system of assembled brachytherapy eye plaques.
… 2D dose distribution in the detector plane using gamma index analysis. Results showed good agreement between the dose distributions and central strengths of detector measured and simulated results for a variety of seed strengths and seed arrangements, enabling the detection of dead or missing …
-
High Frequency Percussive Ventilation For Tumor Motion Immobilization
… photon dose gradient measurements, increasing gamma index by as much as 20 to 30 % from free breathing to HFPV. Similarly, hot and cold spots were reduced by > 50 %. HFPV is reproducible within < 2 mm both intra- and inter- fraction, but it can be further improved by applying minor adjustments …
-
Implementation of Upright Treatments For Lung and Head and Neck Cancers
… of 0.95-1.05 for point dose and obtained a gamma index of 89.25%. Dosimetry verification demonstrated good agreement between the treatment plan doses and the delivered doses and obtained a point-dose dose difference of 2% and gamma analysis index of 100%, which were within the acceptability …
-
Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct
… cine CT and respiratory-averaged 4D-CT using the gamma index. A threshold-based PET segmentation model of size, motion, and source-to-background was developed from phantom scans and validated with 24 lung tumors. Finally, feasibility of integrating cine CT and PET for contouring was assessed on a …
Page 1 of 2