  1. Gamma ray attenuation of the M2/M3 Bradley fighting vehicle

    … dose rate. The M2/M3 Bradley Fighting Vehicle's gamma ray attenuation characteristics will be determined through the use of experimentation and modeling to determine the attenuation factors needed to write such an algorithm.

    gatech Repository record for Gamma ray attenuation of the M2/M3 Bradley fighting vehicle (opens in a new tab)

  2. Update to ANSI/ANS-6.4.3-1991 for low-Z and compound materials and review of particle transport theory

    The ANSI/ANS-6.4.3-1991 Gamma-Ray Attenuation Coefficients and Buildup Factors for Engineering Materials Standard (herein known as ANS Standard), contains derived gamma-ray attenuation coefficients and buildup factors for selected engineering materials and elements for use in shielding calculations …

    unlv Repository record for Update to ANSI/ANS-6.4.3-1991 for low-Z and compound materials and review of particle transport theory (opens in a new tab)

  3. Investigation of Two-Phase Two Component Downflow

    … void fraction, flow patterns, and slip ratios. A gamma ray attenuation technique was used to determine the void fractions and the slip ratios were determined from a simple mass balance. The void fractions and slip ratios of this investigation are compared with existing data. A correlation for …

    marquette Repository record for Investigation of Two-Phase Two Component Downflow (opens in a new tab)

  4. Use of beta-gamma coincidence to improve the quality of transmission scans for PET

    … and on identifying and localizing metastasis. Gamma ray attenuation correction is essential in all quantitative PET studies. The object of this study was to explore the possibility of using beta-gamma coincidence as an attenuation correction technique in order to improve transmission scan image …

    mcgill Repository record for Use of beta-gamma coincidence to improve the quality of transmission scans for PET (opens in a new tab)

  5. Update to ANSI/ANS-643-1991 for high-Z materials and review of particle transport theory

    … Standard (ANSI/ANS-6.4.3, 1991), Gamma-Ray Attenuation Coefficients and Buildup Factors for Engineering Materials, presents evaluated gamma-ray elemental attenuation coefficients and single material buildup factors for selected engineering materials for use in shielding …

    unlv Repository record for Update to ANSI/ANS-643-1991 for high-Z materials and review of particle transport theory (opens in a new tab)

  6. NAPL remediation by vacuum-enhanced recovery: Laboratory and model evaluations

    … soil cell and an automated dual-energy gamma ray attenuation system for the feasibility assessment of VER to remediate free-product NAPL spills. The investigations were conducted in a 1.5 x 1 x 0.08 meter cell filled with heterogeneous soils for the simultaneous and continuous …

    arizona-thes Repository record for NAPL remediation by vacuum-enhanced recovery: Laboratory and model evaluations (opens in a new tab)

  7. A study of sub-orbital and millennial-scale climate variability over the past 1.4 million years in the Northern Atlantic

    … study; they are magnetic susceptibility, natural gamma, spectral reflectance, and GRAPE (Gamma Ray Attenuation Porosity Evaluator). These proxies are used to inform the millennial-scale issue by coherence methods and are also assessed to see which proxies may prove most useful in future high …

    mit Repository record for A study of sub-orbital and millennial-scale climate variability over the past 1.4 million years in the Northern Atlantic (opens in a new tab)

  8. Evaluation of the effect of breast implants on the accuracy of the CT attenuation Correction (CTAC) map for SPECT/CT myocardial perfusion imaging: a phantom study

    … such as ribs or breast tissue lead to gamma ray attenuation. Thisattenuation does not occur equally for all body regions. Photons emitted from deeper structureswill undergo more attenuation than superficial structures, causing artefacts within the imagethat can mimic pathology - such as …

    salford

  9. Evaluation of the effect of breast implants on the accuracy of the CT attenuation Correction (CTAC) map for SPECT/CT myocardial perfusion imaging: a phantom study

    … such as ribs or breast tissue lead to gamma ray attenuation. Thisattenuation does not occur equally for all body regions. Photons emitted from deeper structureswill undergo more attenuation than superficial structures, causing artefacts within the imagethat can mimic pathology - such as …

    salford Repository record for Evaluation of the effect of breast implants on the accuracy of the CT attenuation Correction (CTAC) map for SPECT/CT myocardial perfusion imaging: a phantom study (opens in a new tab)

  10. Heat and mass transfer in freezing unsaturated soil

    … as a function of time were carried out by the gamma-ray attenuation method. The results of these laboratory tests were compared with numerical solutions of the coupled heat and mass trans­fer equations. The model used is essentially that developed by Harlan, in which the major driving force …

    sask Repository record for Heat and mass transfer in freezing unsaturated soil (opens in a new tab)

  11. Integration of ground-penetrating radar and gamma-ray detectors for non-intrusive localisation of buried radioactive sources

    … of ground-penetrating radar (GPR) and gamma ray detectors to improve the non-intrusive localisation of radioactive wastes buried in porous materials such as soil and concrete. The research was undertaken in two phases. In the first phase, a new non-intrusive technique for retrieving the …

    lancaster Repository record for Integration of ground-penetrating radar and gamma-ray detectors for non-intrusive localisation of buried radioactive sources (opens in a new tab)

  12. Measuring physical properties at the surface of a comet nucleus

    … harpoon. A concept for incorporation of a gamma ray attenuation densitometer into the thermal probe is presented and explored. A 137Cs radioisotope source will be mounted near the tip of the probe and semiconductor radiation detectors situated at the top of the probe will monitor the …

    kent Repository record for Measuring physical properties at the surface of a comet nucleus (opens in a new tab)

  13. Measuring Physical Properties at the Surface of a Comet Nucleus

    … harpoon. A concept for incorporation of a gamma ray attenuation densitometer into the thermal probe is presented and explored. A 137Cs radioisotope source will be mounted nearthe tip of the probe and semiconductor radiation detectors situated at the top of the probe will monitor the …

    kent Repository record for Measuring Physical Properties at the Surface of a Comet Nucleus (opens in a new tab)

  14. Extragalactic Background Light inhomogeneities and Lorentz-Invariance- Violation in gamma-gamma absorption and Compton scattering

    Very-high-energy gamma ray photons (VHE; E > 100 GeV) from distant gamma ray objects (e.g. blazars) are expected to be absorbed by the diffuse extragalactic background light (EBL), which leads to a high-energy cut-off in a blazar's spectral energy distribution (SED). But recent observations of …

    nwu-za Repository record for Extragalactic Background Light inhomogeneities and Lorentz-Invariance- Violation in gamma-gamma absorption and Compton scattering (opens in a new tab)

  15. A high resolution record of ice-rafting from the Northeast Pacific

    … rate of coarse lithic material, and on Gamma Ray Attenuation Porosity Evaluator (GRAPE) density in one of the cores from the Gulf of Alaska. The provenance (source) and shape of IRD grains were also evaluated under a microscope. Together, the results provide a high-resolution, 800,000 …

    uvic Repository record for A high resolution record of ice-rafting from the Northeast Pacific (opens in a new tab)

  16. Sources, sinks and scatterers of the ultra-violet background

    … is investigated through its own absorption of gamma rays. The findings suggest that observations at 10GeV may reveal what sources reionized the universe in the first place.

    ohiolink Repository record for Sources, sinks and scatterers of the ultra-violet background (opens in a new tab)

  17. Spectral Imprints from Electromagnetic Cascades in Blazar Jets

    The extragalactic gamma-ray sky is dominated by blazars, active galactic nuclei (AGN) with a relativistic jet that is closely aligned with the line of sight. Galaxies develop an active nucleus if the central supermassive black hole (BH) accretes large amounts of ambient matter and magnetic flux. …

    wurz-thes Repository record for Spectral Imprints from Electromagnetic Cascades in Blazar Jets (opens in a new tab)