Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"gap measurement"”.
-
New Band-gap Measurement Technique for a Half-Metallic Ferromagnet
… with the Fermi level (EF) lying within an energy gap. P of HMFs has been predominantly estimated using Julliere’s formula in a magnetic tunnel junction (MTJ) or measured by the Andreev reflection (AR) at low temperature. Both methods are very sensitive to the surface/interface spin polarisation. …
-
Evaluation of fracture resistance of three post and core systems in endodontically treated teeth under loading to failure; and marginal gap measurement before and after cyclic loading
… by loading to failure, and to measure marginal gaps before and after cyclic loading. Sixty extracted canines were assigned to three groups. The groups tested were: 1) Single cast post and core (Group CP). 2) Prefabricated metal post and composite resin core (Group MR). 3) Glass fiber post and …
-
Gap volume prediction and uncertainty analysis for aircraft wing assembly
Gap measurement is necessary in aircraft assembly to size the shims and ensure product integrity.<br/><br/>However, the current industrial practice employs a manual approach which is not accurate and is rather time-consuming because of the trial-and-error processes involved. The measurement and …
-
Comprehensive Modelling for Eddy Current Based Pressure Tube to Calandria Tube Gap Measurements
… tube (PT) and calandria tube (CT), known as gap, in the CANada Uranium Deuterium (CANDU®) nuclear reactor fuel channels is monitored using a drive-receive eddy current probe. Gap measurement accuracy is crucial to ensure contact does not occur between the PT and CT, as contact can lead to …
-
Numerical Modelling of Eddy Current Probes for CANDU® Fuel Channel Inspection
… the Pressure Tube (PT) to Calandria Tube (CT) gap of CANDU® fuel channels. Accurate gap measurements are crucial to ensure fitness of service; however, variations in probe liftoff, PT electrical resistivity, and PT wall thickness can generate systematic measurement errors. Validated …
-
A Study of Section Gap Acceptance Phenomenon at Stop-Controlled Intersections
This investigation was concerned with the section gap acceptance phenomenon at right angle intersections comprised of an uncontrolled, two-way, two-lane major street, and a stop sign controlled, two-way, two-lane minor street. The objectives of the study included development of a simple but …
-
Investigating and Characterizing Electrical Resistivity Variations Caused by Heat Treatment in Zr2.5%Nb Pressure Tubes
… have consequences for PT-calandria tube (CT) gap measurement error in as-installed PTs. The methods employed included a combination of eddy current (EC) testing (ECT) for resistivity measurements, and scanning electron microscopy (SEM) for microstructural measurements of β_Zr ribbon thickness. …
-
Quantitative comparison of internal adaptation between bulk-fill and traditional multi-increment-fill resin-based composite materials
… RBC placed incrementally by measuring the gap area between the restorative material and the tooth structure and to evaluate aging effect on the internal adaptation. METHODS: A Class I cavity with specific dimensions was prepared using 70 extracted human molar teeth. They were randomly …
-
NON-CONTACT SPATIALLY CONSTRAINED OPTICAL SCANNING METHODS APPLIED FOR DEPTH, WIDTH AND GAP MEASUREMENTS
… the feature dimensions like width, depth and air gaps. Laser diode, Charge coupled device (CCD) and post-processing software using image processing tools are the major components of the non-contact measurement systems. The study involves two methods where the first method comprises of active …
-
FROM POLICY TO PRACTICE: FACTORS DRIVING CYBERSECURITY IMPLEMENTATION FAILURES
… source, resulting in a policy-implementation gap. We apply the ambiguity-conflict model of policy implementation to study this gap for cybersecurity in three important cases. First, we examine the nonuse of system resilience capabilities in U.S. Navy tactical networks. Second, we analyze the …
-
Comprehensive Characterization of Measurement Data Gathered by the Pressure Tube to Calandria Tube Gap Probe
Multi-frequency eddy current measurements are employed in estimating pressure tube (PT) to calandria tube (CT) gap in CANDU fuel channels, a critical inspection activity required to ensure fitness for service of fuel channels. In this thesis, a comprehensive characterization of eddy current gap …
-
A comparison of crown marginal fit fabricated using digital and conventional methods
… of crown margins. Circumferential marginal gap measurements were taken at eight measurement locations: mesial, distal, buccal, palatal, and associated line angles. The marginal gap measurements were made to determine the vertical component of marginal gap, according to the definition of …
-
A Multi-Point Measurement Technique for the Enhancement of Force Measurement with Active Magnetic Bearings (AMB)
… as support bearings and as load sensing measurement tools. Previous work in the area of AMB force measurement has relied upon basic magnetic equations requiring knowledge of coil currents and air gap lengths. Some researchers have utilized magnetic flux probes to eliminate the need for …
-
Marginal Gap and Internal Fit of a Zirconia Crown and Implant Abutment using Three Different Digital Workflows
… with a 5-axis mill. Marginal opening, marginal gap and internal fit were evaluated for all three groups using two forms of measurement, first by sectioning the specimens and evaluating them with aScanning Electron Microscope (SEM). Secondly by a silicone replica technique and Geomagic software. …
-
Exploring the Hardness of Nitride Ceramics: Electronic Properties and Band Gap Studied using Soft X-ray Spectroscopy
… fundamental quantity, the electronic band gap, has also been linked to the intrinsic hardness of materials. The electronic band gap is a seemingly simple quantity, but is difficult to de- termine for novel or complicated materials. Core-level spectroscopy techniques that probe the occupied …
-
Μεθοδολογία ανάπτυξης αντικειμενοστραφούς λογσιμικού για ρομποτικά συστήματα με ανατροφοφότηση από αισθητήρες
… state error at the end effector level, using the measurements that are received from SM. The methodology provides significant benefits to applications that employ external sensors. It achieves the decoupling of the subsystems design from their use and provides the principles of modular …