Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 128 for “"gas analyzer"”.

  1. Análise das emissões gasosas de um veículo flex funcionando com diferentes combustíveis

    … to reduce emission levels of pollutant gases in the atmosphere has intensified in the last decades. In this context, it can be highlighted the modern systems of electronic engine management, new automotive catalysts and the use of renewable fuels which contributes to reduce the …

    brazil-ufrn Repository record for Análise das emissões gasosas de um veículo flex funcionando com diferentes combustíveis (opens in a new tab)

  2. Characterization of nano-scaled metal-hydrides confined in nano-porous carbon frameworks

    … and lower volume than liquid H₂ or compressed gas. Thermodynamic properties of metal hydrides differ between bulk and nano-sized particles. Many metal hydrides with useful volumetric and gravimetric capacities have high decomposition temperatures, but when placed in nano-sized frameworks (or …

    must-thes Repository record for Characterization of nano-scaled metal-hydrides confined in nano-porous carbon frameworks (opens in a new tab)

  3. Design and Construction of a Compact, Modular Fusion Testbed and Proton Source

    … pressure of 4x10⁻⁸ Torr and a background gas of CO and H₂O as measured by a Residual Gas Analyzer (RGA). The plasma source operated with both argon and nitrogen feed gasses and a maximum current of 2.9µA at an acceleration potential of approximately 5kV was achieved.

    carleton Repository record for Design and Construction of a Compact, Modular Fusion Testbed and Proton Source (opens in a new tab)

  4. Molecular Beam Epitaxy-Installation, Vacuum Generation and Growth

    … procedures were followed. Extorr Residal gas Analyzer (RGA) was used for leak detection. A leak free MBE was constructed and UHV was successfully achieved. Finally GaAs thin films were grown by the BME technique.

    mo-state Repository record for Molecular Beam Epitaxy-Installation, Vacuum Generation and Growth (opens in a new tab)

  5. The Effect of Pulp Mill Effluents on the Carbon Dioxide Evolution of Three East Texas Soils

    … evolution was then measured with an infrared gas analyzer to determine the effect of the effluents on the respiration of soil microorganisms. The relationship between effluent treatments was not statistically significant, though detrimental effects were observed in the heavier soil. Irrigation …

    sfasu Repository record for The Effect of Pulp Mill Effluents on the Carbon Dioxide Evolution of Three East Texas Soils (opens in a new tab)

  6. Quality assurance project plan for a ruminant emission measurement system

    … to atmospheric accumulation of greenhouses gases. A Ruminant Emission Measurement System (REMS) was designed, constructed and tested at the Metabolism Unit of the Beef Cattle and Sheep Field Laboratory at the University of Illinois at Urbana-Champaign to quantify these emission rates for …

    uiuc Repository record for Quality assurance project plan for a ruminant emission measurement system (opens in a new tab)

  7. A raman cell based on hollow core photonic crystal fibre for human breath analysis

    … a small hollow core and it can be filled with a gaseous sample (i.e., human breath) for spectral analysis. Our objective is to develop a simple, cost-effective and non-invasive tool based on Raman spectroscopy for breath analysis and potentially lung cancer screening. A Raman-gas analyzer was …

    ubc Repository record for A raman cell based on hollow core photonic crystal fibre for human breath analysis (opens in a new tab) Download PDF for A raman cell based on hollow core photonic crystal fibre for human breath analysis (opens in a new tab)

  8. Characterizing Hydrothermal System Groundwater Dynamics Using Conservative and Non-conservative Tracers: Insights and Implications Drawn from Study at the Taupo Volcanic Zone (New Zealand) and Valles Caldera (USA)

    … and accurate measurements compared to reference gases. Also, the platform captured hourly variability of CO2 in cave air, soil atmosphere, and dissolved CO2 in a cave stream. Humid cave air and dissolved CO2 results were found to be within 15% of a more expensive infrared gas analyzer. For …

    arkansas Repository record for Characterizing Hydrothermal System Groundwater Dynamics Using Conservative and Non-conservative Tracers: Insights and Implications Drawn from Study at the Taupo Volcanic Zone (New Zealand) and Valles Caldera (USA) (opens in a new tab)

  9. Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and nonimaging optics

    … of a hollow waveguide (HW) was investigated as a gas cell for analytical infrared analysis. The analysis was the measurement of carbon monoxide (CO) and nitric oxide (NO) in sidestream cigarette smoke. An FT-IR analysis system was setup with a 3m multi-pass gas cell and a 55cm by 2mm i.d. Ag/AgI …

    gatech Repository record for Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and nonimaging optics (opens in a new tab)

  10. Study of background gas collisions in atomic traps

    … constant depends on the density of background gas and the velocity averaged collisional loss cross section due to collisions. The velocity averaged collisional loss cross section can be calculated and its dependence on trap depth was verified using a magneto-optical trap. This verification …

    ubc Repository record for Study of background gas collisions in atomic traps (opens in a new tab) Download PDF for Study of background gas collisions in atomic traps (opens in a new tab)

  11. Carbon Dioxide and Hydrogen Sulfide Emission Factors Applicable to Wastewater Wet Wells

    … causes potential problems associated with gases which include ammonia, carbon dioxide, carbon monoxide, hydrogen sulfide and methane, in regard to odor nuisance, irritation, toxicity, and microbially induced corrosion. The extent of these problems depends on the emission rates of gases in …

    uno Repository record for Carbon Dioxide and Hydrogen Sulfide Emission Factors Applicable to Wastewater Wet Wells (opens in a new tab)

  12. Computer data acquisition, control, and analysis for the University of Tennessee at Chattanooga's internal combustion engine labratory

    … system to monitor the temperature of the exhaust gases at different locations and the coolants entering and leaving the dynamometer and the radiator.Those thermocouples have an output signal of O - 55 mv.The TESCOM gas analyzer system measures the concentrations of the different gases present in …

    utc Repository record for Computer data acquisition, control, and analysis for the University of Tennessee at Chattanooga's internal combustion engine labratory (opens in a new tab)

  13. A study of lean premixed swirl-stabilized combustion of gaseous alternative fuels.

    … were measured using an electro-chemical gas analyzer and water-cooled stainless steel and expansion-cooled quartz probes. Flame extinction was studied by visual observation of the flame. Combustion related noise was recorded using a condenser microphone and digitized by a high speed data …

    oklahoma-thes Repository record for A study of lean premixed swirl-stabilized combustion of gaseous alternative fuels. (opens in a new tab)

  14. Mitigating nitrous oxide emissions using nitrification and urease inhibitors in corn-based rotations following cover crops termination

    … 4-ha fields using a tunable diode laser trace gas analyzer. The nitrogen use efficiency (NUE) of corn was higher in DIV fields. Compared to the CONV field, the DIV field emitted 9% more N2O, due to higher emissions after the application of fertilizer to corn. The emissions during the 3-week …

    guelph Repository record for Mitigating nitrous oxide emissions using nitrification and urease inhibitors in corn-based rotations following cover crops termination (opens in a new tab)

  15. Construction of a test chamber for ultra-low gas concentrations and its use for tesing novel aluminum nitride sensors by Q-DLTS

    … from the sensor surface while exposed to ambient gas species that altered the electronic structure of the semiconductor surface material. Aluminum Nitride (AlN) was investigated for use as a Quantum Fingerprint[trademark] sensor. AlN sensor fabrication methods were developed and sensors were …

    missouri Repository record for Construction of a test chamber for ultra-low gas concentrations and its use for tesing novel aluminum nitride sensors by Q-DLTS (opens in a new tab)

  16. Temperature Programmed Desorption Study of Dodecanethiol Self-Assembled Monolayers on Ag

    … detection of dodecanethiol by the residual gas analyzer gives a complex spectrum due to multiple cracking fragments that are produced during the ionization of the molecule. The temperature programmed desorption measurements indicate that desorption of the self-assembled monolayer occurs in a …

    texas-state Repository record for Temperature Programmed Desorption Study of Dodecanethiol Self-Assembled Monolayers on Ag (opens in a new tab)

  17. Molecular Beam Epitaxy-Instrumentation And Growth

    … proper baking procedures were followed. Residual gas analyzer (RGA) data were used to analyze the residual gases inside the system and for leak detection. Testing of the radio frequency (RF) plasma source, testing of MBE sources, and degassing the MBE crucibles have been performed prior to thin …

    mo-state Repository record for Molecular Beam Epitaxy-Instrumentation And Growth (opens in a new tab)

  18. Achilles Tendon Changes in Downhill, Level and Uphill Running

    … (240 Hz) videography. A metabolic cart and gas analyzer ensured a similar metabolic cost across grades. Data were analyzed using a forward selection regression. Results showed a decrease in AT CSA from pre-run to post-run (p = .0001). Peak vertical forces were different across grades (p = …

    byu Repository record for Achilles Tendon Changes in Downhill, Level and Uphill Running (opens in a new tab) Download PDF for Achilles Tendon Changes in Downhill, Level and Uphill Running (opens in a new tab)

  19. A study of the high speed diesel engine exhaust with respect to gas composition and smoke density

    A study of exhaust gas composition at various engine speeds, loads, and cooling water temperatures was made on an International Harvester UD-6 Diesel Engine. Simultaneously, smoke density was measured with a smokemeter, the principle of which was based on the obstruction of light. Exhaust gases …

    vt Repository record for A study of the high speed diesel engine exhaust with respect to gas composition and smoke density (opens in a new tab)

  20. Anode material testing in a vacuum diode

    The gas evolved during the operation of a virtual cathode oscillator (vircator), which can be detrimental to the maximum output power, repetition rate, and pulse width was studied. Gases are known to evolve both from processes at the cathode, such as explosive electron emission, and anode processes …

    ttu Repository record for Anode material testing in a vacuum diode (opens in a new tab)

Page 1 of 7