Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"gas detector"”.

  1. Development of a photoacoustic gas detector

    … the dissertation has resulted in a photoacoustic gas detector chamber that has been proved to be applicable for measuring very low concentration gas traces in ambient air. Calculation tools were developed for photoacoustic cell design, namely (i) a method estimating the acoustic quality factor of …

    arizona-thes Repository record for Development of a photoacoustic gas detector (opens in a new tab)

  2. Operational Characteristics of a Fission Gas Detector

    <p>Introduction: One of the major problems associated with the operation of nuclear reactors is the radioactivity hazard caused by the release of fission products from the fuel. In a solid-fuel reactor, the uranium is usually present in an allow or in the form of UO<sub>2</sub>, either in the pure …

    utk-theses Repository record for Operational Characteristics of a Fission Gas Detector (opens in a new tab)

  3. Development of highly selective single sensor microfluidic-based gas detector

    This research aims at the integration of gas sensors into microfluidics platforms to develop low-cost, portable, and highly selective (with a fast recovery time) detection tools for discrimination of volatile organic compounds (VOCs). The main advantage of the proposed device over previous …

    ubc Repository record for Development of highly selective single sensor microfluidic-based gas detector (opens in a new tab) Download PDF for Development of highly selective single sensor microfluidic-based gas detector (opens in a new tab)

  4. Detection algorithms for the Nano nose

    … when exposed to radiation passing through a gaseous mixture. The digital patterns correspond to the amount of photocurrent registered on each of the sensors. The problem is to find the gas constituents in the gaseous mixture and estimate their concentrations. This thesis outlines an algorithm …

    unlv Repository record for Detection algorithms for the Nano nose (opens in a new tab) Download PDF for Detection algorithms for the Nano nose (opens in a new tab)

  5. Stochastic Programming Approaches for the Placement of Gas Detectors in Process Facilities

    … the proper selection of the necessary types of gas detectors needed is important, appropriate placement of these detectors is required in order to have a well-functioning gas detection system. However, the uncertainty in leak locations, gas composition, process and weather conditions, and …

    tamu Repository record for Stochastic Programming Approaches for the Placement of Gas Detectors in Process Facilities (opens in a new tab)

  6. Využití přístroje GDA-2 v praktické činnosti jednotek Hasičského záchranného sboru

    … je zaměřena na využití mobilního analyzátoru Gas Detector Array GDA 2 jednotkami Hasičského záchranného sboru. Cílem práce v teoretické části bylo seznámit se s tímto přístrojem a s možnostmi jeho využití a popsat analytické principy využívané tímto analyzátorem. Experimentální část byla …

    brno-tech Repository record for Využití přístroje GDA-2 v praktické činnosti jednotek Hasičského záchranného sboru (opens in a new tab)

  7. Helium plasma based gas detectors for volatile organic compounds

    … to both detect and identify harmful VOCs. Gas chromatography (GC) is one of the most reliable and commonly used techniques for the detection of VOCs. However, traditional GC systems are usually bulky, energy-intensive, and expensive. In comparison, micro gas chromatography (μGC) systems are …

    qu-belfast Repository record for Helium plasma based gas detectors for volatile organic compounds (opens in a new tab) Download PDF for Helium plasma based gas detectors for volatile organic compounds (opens in a new tab)

  8. Mathematical Programming Formulations for the Optimal Placement of Imperfect Detectors with Applications to Flammable Gas Detection and Mitigation Systems

    The placement of detectors in mitigation systems is a difficult problem usually addressed in the industry via qualitative and semiquantative approaches. Simplifications are used to circumvent difficulties regarding problem size, parameter uncertainty, and lack of information concerning leak …

    tamu Repository record for Mathematical Programming Formulations for the Optimal Placement of Imperfect Detectors with Applications to Flammable Gas Detection and Mitigation Systems (opens in a new tab)

  9. Radiatively-driven Natural Supersymmetry

    … offer a means of discovery, with a 1-ton noble gas detector effectively probing the entirety of RNS parameter space.

    oklahoma-thes Repository record for Radiatively-driven Natural Supersymmetry (opens in a new tab)

  10. A portable laser system for the remote detection of methane gas

    We have developed an open-path hand-held gas detector incorporating a distributed feedback InGaAs laser diode at 1.65μm. Incorporated into a hand-held transceiver unit, the emitted laser beam is backscattered from nearby surfaces, collected and focussed onto an amplified InGaAs detector using a …

    glasgow Download PDF for A portable laser system for the remote detection of methane gas (opens in a new tab)

  11. Development of time-to-digital converter based on field-programmable gate arrays

    … apparatus includes a ring-imaging Cherenkov detector that was upgraded in 2016 with a set of new photon detectors based on micro-pattern gas detector technologies. The objective of this thesis was the development of a time-to-digital converter (TDC) module that provides the digital readout …

    freiburg-diss Repository record for Development of time-to-digital converter based on field-programmable gate arrays (opens in a new tab)

  12. The mechanism of lead poisoning in catalytic gas detectors

    Currently, gas detectors are liable to fail unpredictably when working in the field. For the obvious reason of safety the development of reliable detectors of flammable gases at both low and potentially explosive concentrations is essential. The purpose of this investigation has been to study the …

    city-london Download PDF for The mechanism of lead poisoning in catalytic gas detectors (opens in a new tab)

  13. Optical Micro-Electro-Mechanical Systems for Add/Drop Multiplexing and Infrared Spectroscopy

    … density. The second system studied is an optical gas spectrometer. A scanning MEMS mirror was used with various additional optical components to create a Non- Dispersive Infra-Red (NDIR) gas detector. The MEMS mirror is used in conjunction with a Linear Variable Filter (LVF) to scan a particular …

    cornell Repository record for Optical Micro-Electro-Mechanical Systems for Add/Drop Multiplexing and Infrared Spectroscopy (opens in a new tab)

  14. Diode laser spectroscopy for high-enthalpy facility and hypersonic flight characterisation

    … log-ratio detection techniques. When log-ratio detectors are used in luminous environments and when the stray light intensity falling on the photodiodes of the detector is significant relative to the intensity of the laser used in the system, the baseline of the absorption spectrum measured is …

    unsw Repository record for Diode laser spectroscopy for high-enthalpy facility and hypersonic flight characterisation (opens in a new tab)

  15. Commissioning and characterization of a GEM stand for testing the HVMAPS of the MOLLER experiment

    … Achieving this precision requires tracking detectors with excellent spatial resolution and fast readout capabilities. To meet these requirements, the MOLLER experiment plans to employ High Voltage Monolithic Active Pixel Sensors (HVMAPS) in its main integrating detector. To evaluate their …

    manitoba Repository record for Commissioning and characterization of a GEM stand for testing the HVMAPS of the MOLLER experiment (opens in a new tab)

  16. MULTIPLE GAS SENSING DEVICE BASED ON NANO-POROUS STRUCTURE OF ZEOLITE COATED WITH NILE RED DYE

    Gas detection is vital in different fields including environmental applications, clinical analysis, and homeland security. To perform these tasks the sensors need to be stable, sensitive, selective, operating at room temperature, rapidly responding, and easy to regenerate. On the other hand, most …

    temple Repository record for MULTIPLE GAS SENSING DEVICE BASED ON NANO-POROUS STRUCTURE OF ZEOLITE COATED WITH NILE RED DYE (opens in a new tab)

  17. MicroGC: Of Detectors and their Integration

    Gaseous phase is a critical state of matter around us. It mediates between the solid crust on earth and inter-stellar vacuum. Apart from the atmosphere surrounding us where compounds are present, natively, in a gaseous phase, they are also trapped within soil and dissolved in oceanic water. …

    vt Repository record for MicroGC: Of Detectors and their Integration (opens in a new tab)

  18. Optimization of spherical proportional counter backgrounds and response for low mass dark matter search

    … Interacting Massive Particles (WIMP). The first detector developed for this goal is a 60 cm diameter sphere installed at the Laboratoire Souterrain de Modane in France. In 2015, the collaboration took a run with neon as the target material for an exposure of 9.7 $\mathrm{kg\cdot days}$. This run …

    queens Repository record for Optimization of spherical proportional counter backgrounds and response for low mass dark matter search (opens in a new tab)

  19. Development of a THGEM Imaging Detector with Delay Line Readout

    <p>Position sensitive detectors represent a class of particle detectors widely used in high-energy physics, astrophysics, biophysics and medicine for imaging the spatial distribution of various radioactive sources. In recent years, a new class of gas based detectors, so-called micropattern gas …

    mcmaster Repository record for Development of a THGEM Imaging Detector with Delay Line Readout (opens in a new tab)

Page 1 of 2