Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"gauge calibration"”.

  1. Fiber optic strain gauge calibration and dynamic flexibility transfer function identification in magnetic bearings

    … uncertainties. Recent advances in the strain-gauge technology have provided a new method for measuring magnetic bearing forces. Fiber optic strain gauges are roughly 100 times more sensitive than conventional strain gauges and are not affected by electro-magnetic interference. At the Texas A&M …

    tamu Repository record for Fiber optic strain gauge calibration and dynamic flexibility transfer function identification in magnetic bearings (opens in a new tab)

  2. PROCEDURES TO OBTAIN ACCURATE MEASUREMENT FROM A GAS FUELD BURNER

    … burning assumption and stagnant layer solution. Calibration procedures for thermopile-type heat flux gauge was developed and compared with NIST BFRL heat flux gauge calibration system. Calibration of gauges has found to be possible without controlling the temperature. The absorptivity and …

    maryland Repository record for PROCEDURES TO OBTAIN ACCURATE MEASUREMENT FROM A GAS FUELD BURNER (opens in a new tab)

  3. A system for high strain rate interruptible tensile tests

    … properties of the hardware are taken. Strain gauge calibration tests were then conducted, followed by a rigorous commissioning process. This involved fine-tuning trap impedances and verification of the complex critical subsystems. As the commissioning process progressed, emergent flaws were …

    cape-town Repository record for A system for high strain rate interruptible tensile tests (opens in a new tab)

  4. Mathematical Model Validation of a Center of Gravity Measuring Platform Using Experimental Tests and FEA

    … for this project used an array of six strain gauges, four C2A-06-062LT-120 Tee Rosettes and two C2A-06-031WW-120 Stacked Rosettes. They were bonded onto the legs of three truss shaped bipods. Results from the Platform Tilting Tests could not be used to validate the CG model as the measured CG …

    calpoly Repository record for Mathematical Model Validation of a Center of Gravity Measuring Platform Using Experimental Tests and FEA (opens in a new tab)

  5. A Study of the Mesosphere-Lower Thermosphere: Noctilucent Cloud Observations and Rocket Borne Density Measurements

    … phase speed of 22m/s_. Two CONE ionization gauges are calibrated for a rocket campaign which took place in February of 2009. Their ion, emission, and filament currents are discussed as well as the results of a least squares fit to write the pressure as a function of the normalized ion …

    clemson Repository record for A Study of the Mesosphere-Lower Thermosphere: Noctilucent Cloud Observations and Rocket Borne Density Measurements (opens in a new tab)

  6. Cloud Water Interception in Hawaiʻi

    … landscapes of the Hawaiian Islands.Passive fog gauges are one of the most used methods to study cloud water interception; however, the interpretation of fog gauge measurement is not straightforward, and the long lack of a standard for the methodology has caused confusion and prevented almost all …

    hawaii Repository record for Cloud Water Interception in Hawaiʻi (opens in a new tab)

  7. Využití optického odměřovacího systému Renishaw pro snímače a komparátory

    Diplomová práce se zabývá popisem vybraných optických systémů v metrologii délky. Hlavním přínosem práce je návrh a realizace snímače s optickým systémem VIONiCplus a návrh aplikace tohoto odměřovacího systému do délkových komparátorů. Práce obsahuje experimentální ověření využití optického systému …

    brno-tech Repository record for Využití optického odměřovacího systému Renishaw pro snímače a komparátory (opens in a new tab)