  1. THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER

    … a tissue-mimicking material and produce a 3D gelatin that has density of approximately a human lung, which is in the ranges of (0.25 – 0.35) g/cm3. Tissue equivalent models are important in order to study the radiation dose planned for patients. To achieve the desired density of a human …

    mcmaster Repository record for THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER (opens in a new tab)

  2. DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER

    … is to fabricate a transparent radiochromic gel dosimeter that may be used as quality assurance tool. Also, the fabricated gel must be analyzed using a simple optical read-out technique.</p> <p>Gel dosimeters are gels that undergo some chemical changes upon irradiation as a function of …

    mcmaster Repository record for DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER (opens in a new tab)

  3. Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery

    … This experiment evaluates the use of ClearView gel dosimeters as an alternative to current methods for small field dosimetry in SRS testing. ClearView differs from other gel dosimeters in that it uses tetrazolium salt in its chemical make-up in place of traditional Fricke-type compounds. Using a …

    ohiolink Repository record for Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery (opens in a new tab)

  4. The dual development of an optical tomographic scanner and three dimensional gel dosimeter for complex radiotherapy verification

    … delivered are verified by volumetric gel dosimetry. The development of tissue equivalent gel dosimeters that provide an integrated assessment of the dynamic treatments, are primarily imaged with Magnetic Resonance Imaging (MRI).This thesis describes the dual development and assessment …

    hull Repository record for The dual development of an optical tomographic scanner and three dimensional gel dosimeter for complex radiotherapy verification (opens in a new tab)

  5. Improved recipes for leuco-crystal violet micelle gel dosimeters

    … micelle (RM) leuco-crystal violet (LCV) gel dosimeter was proposed using full-factorial designed experiments and model-based optimization. Linear regression models were used to optimize gel recipes with regard to high dose sensitivity (DS) and minimal dose-rate dependence. The proposed …

    queens Repository record for Improved recipes for leuco-crystal violet micelle gel dosimeters (opens in a new tab)

  6. MR based frickle-gelatin dosimetry : uncertainty evaluation and computerised analysis of measured dose distributions

    … with the use of integrating continuous 3D dosimeters such as gel based Fricke dosimeters. Accurate knowledge of the ability of these dosimeters to measure adequately and precisely the delivered dose is a prerequisite for their clinical use. The magnetic properties of the ferrous and ferric …

    mcgill Repository record for MR based frickle-gelatin dosimetry : uncertainty evaluation and computerised analysis of measured dose distributions (opens in a new tab)

  7. Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων

    … due to energy dependence of available dosimeters and steep dose gradients demanding high spatial resolution and precise dosimeter positioning. The scope of this thesis is to evaluate the suitability of radiochromic EBT3 films as well as the one of a novel 3D radiochromic micelle gel …

    greece Repository record for Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων (opens in a new tab)

  8. Development and implementation of 3D-dosimetric end-to-end tests in adaptive radiation therapy of moving tumors

    … in combination with a 3-dimensional (3D) polymer gel dosimeter (PGD). Different experimental settings of increasing complexity were tested in terms of (i) accuracy, (ii) feasibility of clinical workflows testing, (iii) validation of clinical concepts for motion-compensated treatments, (iv) …

    heid-diss Repository record for Development and implementation of 3D-dosimetric end-to-end tests in adaptive radiation therapy of moving tumors (opens in a new tab)

  9. X-ray computed tomography for performing polymer gel dosimetry : a feasibility study

    … high resolution three dimensional (3D) dosimeter. Polymer gels are novel, inherently 3D, tissue equivalent radiation dosimeters. Traditionally, dose distributions recorded in polymer gel are read out using magnetic resonance imaging (MRI). Presented here is a feasibility study on a new …

    ubc Repository record for X-ray computed tomography for performing polymer gel dosimetry : a feasibility study (opens in a new tab)

  10. Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters

    A mathematical model for polymer gel dosimeters was extended to simulate the effects of radiation depth doses of various radiation beams on the mass of polymer formed. The influences of monomer diffusion and temperature variation were investigated and predicted by the model. Simulation results …

    queens Repository record for Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters (opens in a new tab)

  11. Cone Beam Optical Computed Tomography-Based Gel Dosimetry

    … target accuracy of ± 5% for the dose delivery. Gel dosimetry is an attractive option for realizing a tissue-equivalent, 3D dose verification tool with high resolution readout capabilities. However, much important work remains to be completed prior to its acceptance in the clinic. The careful …

    queens Repository record for Cone Beam Optical Computed Tomography-Based Gel Dosimetry (opens in a new tab)

  12. Design of a solid tank prototype optical computed tomography scanner

    … matching baths that are often found with OCT for gel dosimeters. As a result of the solid tank design there is lensing that the fan-beam experiences while passing through a gel dosimeter, this lensing makes filtered back projection (FBP) less suitable than IR for image reconstruction. Methods: The …

    ubc Repository record for Design of a solid tank prototype optical computed tomography scanner (opens in a new tab)

  13. Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification

    … challenge that utilizes a 3D NIPAM polymer gel dosimetry system with CBCT readout to verify the dosimetric and spatial accuracy of stereotactic radiosurgery (SRS) and spatially fractionated radiotherapy (SFRT) technique. Three main objectives of this work are 1) to evaluate the …

    ubc Repository record for Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification (opens in a new tab)

  14. Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry

    … of MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) polymer gel dosimeters have been characterized. The variations of speed of sound, ultrasonic attenuation coefficient and density of MAGIC gel with radiation dose and temperature have been quantified. This extends work …

    soton Repository record for Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry (opens in a new tab)

  15. Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide

    … dose response and ease of manufacture of polymer gel dosimeters that use N-isopropyl acrylamide (NIPAM) as the monomer. An alternative carageenan gelling agent was tested in place of gelatin. Although the carageenan did reduce the gelling time for the dosimeter solution, the dose response of the …

    queens Repository record for Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide (opens in a new tab)

  16. Prototype fan beam optical computed tomography scanner for three-dimensional radiotherapy dose verification

    … (OptCT) scanner for three-dimensional polymer gel dosimetry of complex radiotherapy protocols has been developed. This study documents the design. construction and characterization of the system, as well as preliminary reconstructed optical attenuation images and dosimetric verification …

    uvic Repository record for Prototype fan beam optical computed tomography scanner for three-dimensional radiotherapy dose verification (opens in a new tab)

  17. Volumetric, Magnetic Resonance-Visible, and Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy

    … existing and novel formulations of radiochromic gel dosimeters. After the optimal radiochromic gel formulation was identified, it was characterized for dose linearity, radiological properties, reproducibility, time stability, energy dependence, reusability, dose rate dependence, fractionation …

    uthsc Repository record for Volumetric, Magnetic Resonance-Visible, and Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy (opens in a new tab)

  18. Assessment of X-ray computed tomography dose in normoxic polyacrylamide gel dosimetry

    Polymer gel dosimetry, in conjunction with x-ray computed tomography (x-ray CT) imaging, is a three-dimensional dosimetric tool that shows promise in the verification of complex radiation therapy treatments. Previous studies have shown that x-ray CT imaging of gel dosimeters is robust, easy-to-use, …

    uvic Repository record for Assessment of X-ray computed tomography dose in normoxic polyacrylamide gel dosimetry (opens in a new tab)

  19. Applications of x-ray computed tomography polymer gel dosimetry

    … advances. X-ray computed tomography (CT) polymer gel dosimetry is a unique type of dosimeter that has many advantages and the potential to address some of the challenges in the verification of dose delivery and calculation in radiation therapy. This dissertation investigates the advancement of an …

    uvic Repository record for Applications of x-ray computed tomography polymer gel dosimetry (opens in a new tab)

  20. Three-dimensional dosimetry around small distributed high-Z materials

    … last decade, significant improvements in polymer gel dosimetry have been made allowing for improved 3D dose measurements. The purpose of this study was to better understand the dose around distributed high-Z materials irradiated by high energy photon beams and investigate the feasibility of 3D …

    umn Repository record for Three-dimensional dosimetry around small distributed high-Z materials (opens in a new tab)