Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"generator winding"”.
-
Wind Turbine Generator Overheating Solution
… point. The overheating issue of the wind turbine generator system is the subject of this research. Windings and bearings are two primary components susceptible to failure in the wind turbine generator. Overheating accelerates the generator windings and bearings failure. A detailed investigation …
-
Digital Modelling of the Excitation and Short-Circuit Transient Characteristics of the Short-Circuit Generators
… up to 100kA, two specially designed turbo-generators are being used with a total capacity of 4000MVA. Each of generators during the short-circuit test is excited by a separate driven exciter to provide the excitation current. Flying excitation method which is used to provide the right value …
-
Compact harsh environment energy conversion systems
… design was developed. The application of a dual winding exterior rotor PM machine in a downhole environment enabled a significant increase in the application’s torque capability, provided protection against generator winding over voltage, and reduced parts count. Comprehensive switching device …
-
Condition Monitoring of Power Equipment: Partial Discharge Analysis
… Power equipment such as power cables, generators, and gas-insulated switchgear (GIS) are significant components of the grid system, which need to operate reliably without any random failure or outage. Power failures that occur in equipment are mostly related to their insulation system. …
-
Using Intrinsic 3rd Harmonics for Large Synchronous Generator Insulation Fault Condition Monitoring
… the operational health of large synchronous generators is a primary concern for generator owners. This concern has become more pressing as many owners seek to extend the lifespan of their aging generation facilities. With the construction of numerous data centers and the subsequent rise in …
-
CONDITION MONITORING OF MARINE ELECTRICAL GENERATORS FOR IMPROVED MAINTENANCE LEADING TO INCREASED RELIABILITY AND AVAILABILITY
The stator winding short circuit faults in Brushless Synchronous Generator (BLSG) used for onboard power generation in ships may lead to catastrophic failures and back out. Hence, it is important to develop Condition Monitoring (CM) techniques for the BLSG to improve its reliability and …
-
Deformačně napěťová analýza rotorového svazku synchronního generátoru
Cílem této diplomové práce je zjištění rozložení napětí a deformace v plechách rotoro-vého svazku a v kritických místech opěrných tyčí synchronního generátoru. Počítány a vzá-jemně porovnány jsou výsledky výpočtu analytického, numerického s využitím 2D modelu a numerického s využitím 3D modelu ve …