Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 101 for “"glenoid"”.

  1. Glenoid Baseplate Micromotion in Reverse Total Shoulder Arthroplasty

    … anatomy of the joint by replacing the glenoid with a spherical component and the humeral head with a cup-like component. This design allows for the deltoid to replace the function of the rotator cuff. While this restores function for patients, a major complication with the procedure is …

    clemson Repository record for Glenoid Baseplate Micromotion in Reverse Total Shoulder Arthroplasty (opens in a new tab)

  2. Anatomical, biomechanical and histological evaluation of the glenoid labrum

    The glenoid labrum is an integral part of the highly mobile glenohumeral joint. Labral injury can be detrimental to the movement and function of the shoulder. Therefore, an in-depth investigation of glenoid labrum microanatomy may improve our understanding of its roles and functions in the …

    edinburgh Repository record for Anatomical, biomechanical and histological evaluation of the glenoid labrum (opens in a new tab)

  3. Morphological and mechanical analysis of the glenoid trabecular bone

    Bone quality is an important factor in glenoid component fixation and ultimately the long-term outcome of shoulder replacement. The aims of this study were to explore the relationship between bone morphology and mechanical properties, to develop an experimental fixation model to explore the …

    whiterose Download PDF for Morphological and mechanical analysis of the glenoid trabecular bone (opens in a new tab)

  4. Anatomy, Histological Features, Innervation and Vascularity of the Glenoid Labrum

    … between the head of the humerus and the glenoid fossa of the scapula, the latter being deepened and extended by the triangular fibrocartilaginous glenoid labrum attached peripherally to the margin of the glenoid fossa. The glenoid labrum plays an important role in glenohumeral joint …

    dundee Repository record for Anatomy, Histological Features, Innervation and Vascularity of the Glenoid Labrum (opens in a new tab) Download PDF for Anatomy, Histological Features, Innervation and Vascularity of the Glenoid Labrum (opens in a new tab)

  5. Biomechanical Evaluation of Glenoid Baseplate Stability in Total Shoulder Arthroplasty

    … of shoulder arthroplasty, loosening of the glenoid component is a continuing challenge. Glenoid baseplate loosening is sometimes difficult to assess clinically and is typically only assessed following discomfort or total failure of the implant. Therefore, it is important that accurate and …

    buffalo Repository record for Biomechanical Evaluation of Glenoid Baseplate Stability in Total Shoulder Arthroplasty (opens in a new tab)

  6. Biomechanical Evaluation of Provocative Tests for Superior Glenoid Labrum Lesions

    … elicits pain and/or apprehension in the superior glenoid region, a positive sign of superior labral pathology. Eleven male subjects with no history of shoulder pathology were recruited to participate in the study. Their average age was 25 years. Each subject was subjected to 10 provocative tests …

    boise Repository record for Biomechanical Evaluation of Provocative Tests for Superior Glenoid Labrum Lesions (opens in a new tab)

  7. Micromotion and Strength of the Glenoid Component in Reverse Total Shoulder Arthroplasty: The Effect of Malpositioning Versus Optimal Clinical Positioning in the Simulated B2 Glenoid

    Glenoid deformity remains one of the most difficult challenges facing reverse total shoulder arthroplasty (RTSA) surgeons today as approximately 42,000 cases are performed in the United States each year (Schairer et al., 2015; Day et al., 2010). While RTSA aids in reducing pain and improving …

    clemson Repository record for Micromotion and Strength of the Glenoid Component in Reverse Total Shoulder Arthroplasty: The Effect of Malpositioning Versus Optimal Clinical Positioning in the Simulated B2 Glenoid (opens in a new tab)

  8. Biomechanical evaluation of Glenoid Component Stability after ATSA under phasic cyclic loading

    … it may be associated with many complications. Glenoid loosening is thought to be the most common complication of anatomic total shoulder arthroplasty (ATSA); its underlying causes could be mechanical (abnormal loading), septic (infections) or aseptic (autoimmune reaction). This study discusses …

    lmu-germany Repository record for Biomechanical evaluation of Glenoid Component Stability after ATSA under phasic cyclic loading (opens in a new tab)

  9. Inlay vs. Onlay: A Comparison of Two Glenoid Systems in Total Shoulder Arthroplasty

    Loosening of the glenoid component via a 'rocking horse' phenomenon, whereby the glenoid loosens as a result of edge loading of the implant during mild off-axis motion, is a common complication of total shoulder arthroplasties (TSAs). Recently, a partial glenoid resurfacing implant, known as a …

    clemson Repository record for Inlay vs. Onlay: A Comparison of Two Glenoid Systems in Total Shoulder Arthroplasty (opens in a new tab)

  10. The Evolution of the Glenoid Region in the Hominidae: Implications for Hominid Phylogenetics

    … exhibit more interspecific variation in glenoid region morphology than Homo. Chimpanzees and the earliest hominid taxa exhibit similar glenoid region morphologies and are readily distinguishable from later australopithecines and Homo. The Ardipithecus and Australopithecus anamensis …

    uiuc Repository record for The Evolution of the Glenoid Region in the Hominidae: Implications for Hominid Phylogenetics (opens in a new tab)

  11. Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty

    Reverse shoulder arthroplasty (RSA) is typically performed in patients with injured or deficient rotator cuff muscles. Loosening remains to be one of the principal modes of implant failure and the main complication leading to revision. The objective of this study was to mechanically evaluate …

    queens Repository record for Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty (opens in a new tab)

  12. The influence of bony glenoid reconstruction procedures on soft tissue integrity of the shoulder

    Introduction: Glenoid bone loss resulting from fractures or erosions caused by recurrent shoulder dislocations is a common cause of anterior shoulder instability. If the bony defect reaches a critical size, soft tissue surgery such as labrum refixation cannot achieve sufficient stability. In these …

    fu-berlin Repository record for The influence of bony glenoid reconstruction procedures on soft tissue integrity of the shoulder (opens in a new tab)

  13. A Pilot Study on the Short Term Effects of the Herbst Appliance on the Glenoid Fossa

    … 3) There seems to be little effect on the glenoid fossa, based on the points measured in this study, to support migration of the fossa.

    loma-linda Repository record for A Pilot Study on the Short Term Effects of the Herbst Appliance on the Glenoid Fossa (opens in a new tab)

  14. A Biomechanical Comparison Of Varying Peg Angles On Glenoid Implant Stability For Anatomic Total Shoulder Arthroplasty

    … procedure in which both the humeral head and the glenoid cavity are replaced with implants resembling the natural anatomy of the shoulder. Several complications may occur after an ATSA, but the most common is glenoid loosening, which makes up about 37.7% of these complications. The overall …

    uab Repository record for A Biomechanical Comparison Of Varying Peg Angles On Glenoid Implant Stability For Anatomic Total Shoulder Arthroplasty (opens in a new tab)

  15. Protocol Development of a Study of Loading and Stability of the Glenoid Inlay versus Onlay Shoulder System

    … choice may be considered: the onlay or inlay glenoid component. The purpose of this study is to examine the contact pressures and implant stability associated with fatigue loading of these two types of glenoid components. The current standard of choice is that of the onlay design, which sits …

    clemson Repository record for Protocol Development of a Study of Loading and Stability of the Glenoid Inlay versus Onlay Shoulder System (opens in a new tab)

  16. Finite Element Analysis Of Post Vs Threaded-Post Glenoid Baseplates In Reverse Total Shoulder Arthroplasty: A Comparative Study

    … interface and von Mises stress in the glenoid and baseplate. Total micromotion remained below the 150 µm osseointegration threshold for both designs. At 60° and 120°, the threaded-post significantly reduced mean total micromotion (60°: 13.80 µm versus 18.37 µm, p < 0.001; 120°: 15.41 µm …

    uab Repository record for Finite Element Analysis Of Post Vs Threaded-Post Glenoid Baseplates In Reverse Total Shoulder Arthroplasty: A Comparative Study (opens in a new tab)

  17. A proposed method for evaluation of morphological changes in the condyle and glenoid fossa by cone beam computed tomography

    The difficulty with three-dimensional analyses remains with the myriad of data that is possible to derive from a volume. The goal of this study is to report 3D changes in the temporomandibular joint in a reliable and quantifiable way. The approach included plotting specific referents on the …

    wvu Repository record for A proposed method for evaluation of morphological changes in the condyle and glenoid fossa by cone beam computed tomography (opens in a new tab)

Page 1 of 6