Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 61 for “"glucose biosensor"”.
-
Glucose Biosensor Using Electrospun Mn2O3-Ag Nanofibers
… then employed as the immobilization matrix for glucose oxidase (GOD) to construct an amperometric glucose biosensor. A notable enhancement of direct electron transfer between GOD and the electrode is observed at the Mn2O3-Ag-GOD modified electrode with a fast electron transfer rate constant. The …
-
Development of a regenerable glucose biosensor probe for bioprocess monitoring
… and commercialization of enzyme-based biosensors for on-line bioprocess monitoring and control has been slowed by problems relating to the in situ sterilizability of the probe and the stability of the enzyme component. A novel technology is presented here which addresses both of these …
-
The Characterization and Optimization of an IrOx-based Glucose Biosensor
… diabetes must continuously monitor their blood glucose levels (BGLs) throughout the day to ensure their BGLs stay within the normal range. For this reason, glucose sensors must be extremely reliable, robust, accurate, reproducible and sensitive. However, glucose sensor designs face obstacles, …
-
Mechanistic Modeling of a Cell-Free Glucose Biosensor for Therapeutic Applications
… need for rapid and robust detection of blood glucose levels. Recent advancements in synthetic biology, particularly in cell-free bio-sensing, address this need. Cell-free biosensors provide direct access to the translation machinery thereby promoting enhanced sensitivity and reduced response …
-
Toward an in-situ glucose biosensor for animal cell culture monitoring and control
… of an in-situ sterilizable, regenerable biosensor for monitoring and control of glucose concentration in bioreactorscale animal cell culture. Long-term stability and in-situ steam sterilization capability are obstacles preventing development of industrially acceptable biosensors. These …
-
Development of an enzymatic glucose biosensor for applications in wearable sweat-based sensing
… wearable monitors for continuously sensing blood glucose levels. Diabetes currently affects nearly 10% of the American population, a number that is expected to rise in the near future, prompting increased interest in noninvasive methods of monitoring glucose levels. This interest in noninvasive …
-
Biocompatibility studies on a glucose biosensor : investigation of the in-vivo sensitivity loss phenomenon
… the inception of the in-vivo electrochemical glucose biosensor, great expectations seemed to await insulin-dependent diabetics. However, even after decades of intense research, the sensor still suffers a major disadvantage: loss of sensitivity upon implantation in-vivo . If an implantable …
-
Amperometric Glucose Biosensor by Means of Electrostatic Layer-by-layer Adsorption onto Electrospun Polyaniline Fibers
An amperometric glucose biosensor was fabricated using electospun polyaniline fibers. Polyaniline was reacted with camphorsulfonic acid to produce a salt, which was then dissolved in chloroform containing polystyrene. Using this solution, fibers were formed and collected by electrospinning. Glucose …
-
Development and Microscaling of a Novel Glucose Biosensor for Application in a Minimally Invasive Sampling Platform
… treatment involves self-monitoring of blood glucose levels by analysis of a blood sample obtained by "finger-pricking". This suffers from non-compliance, and samples at a rate much lower than the Shannon frequency of blood glucose levels. The e-Mosquito provides near-painless sampling, is …
-
Exploration of nitric oxide generation from S-nitrosoglutathione for the advancement of anti-fouling glucose biosensor membrane materials
… medical devices such as implantable glucose sensors suffer from biofouling which limits the lifetime of the device and puts the patient at risk of arterial embolism and infection. Researchers have been developing medical device coatings to address the two causes of surface biofouling: …
-
Creating Unique Chemistries within Porous Silicon Platforms & Piezoelectric Inkjet Printed Glucose Biosensor Based on Protein and Luminophore Doped Hybrid Xerogels
… dimensional (3D) printing technique to optimize glucose biosensors. The overall performance of PIP biosensors is evaluated in comparison to contact pin-printing (CPP) platforms. Additionally, confocal PL microscopy is utilized to more fully characterize the CPP and PIP glucose biosensor platforms.
-
Multimaterial, multifunctional fiber-based designs for integration into minimally invasive and wearable, translatable medical devices
… devices. A minimally invasive interstitial fluid glucose biosensor as well as a wearable sweat sensing glucose biosensor are presented. Moreover, a conductive fiber design is evaluated for pH sensing and integrative capabilities. Additional work and future areas of interest are discussed, …
-
Redukuoto grafeno oksido ir polianilino nanopluoštų nanokompozito taikymas elektrocheminiuose gliukozės biologiniuose jutikliuose /
… nanocomposite in fabrication of amperometric glucose biosensor. In this study PANI nanowires were synthesized using an interphase polymerization method. The diameter of the prepared nanostructured PANI nanowires was 118 ± 19 nm. The sucessfull synthesis of rGO was confirmed using X-ray …
-
Poli(pirol-2-karboksirūgšties) sintezė ir taikymas gliukozės biologiniuose jutikliuose /
… acid and its application in glucose biosensors. These analytical devices are able to specifically detect glucose in complex samples. Biosensors are being developed in order to design stable, long-lasting, reliable analytical tool. In this work polypyrrole-2-carboxylic acid was …
-
Synthesis and Application of Polypyrrole-2-Carboxylic Acid in Glucose Biosensors /
… acid and its application in glucose biosensors. These analytical devices are able to specifically detect glucose in complex samples. Biosensors are being developed in order to design stable, long-lasting, reliable analytical tool. In this work polypyrrole-2-carboxylic acid was …
-
Formation and characterization of prussian blue, polypyrrole and glucose oxidase modified electrodes for amperometric detection of glucose /
To form and investigate amperometric glucose biosensor by modifying graphite and titanium electrodes with composite layer of prussian blue, polypirrole and glucose oxidase (PB-Ppy-GOx).
-
Ferocenu modifikuoto grafeno oksido taikymas gliukozės ir sarkozino biojutikliams kurti /
… bachelor’s thesis focused on the development of biosensors capable of detecting sarcosine and glucose. The glucose biosensor was used as a model system for optimizing the sarcosine biosensor. Sarcosine was chosen as the analyte due to the potential link described in the literature between …
-
Polianilino saviorganizuojančių monosluoksnių taikymas jutikliuose /
… hand, the Au-PANI electrode with immobilized glucose oxidase enzyme, exhibited good glucose sensitivity, specificity, and reaction speed. Also we identified, that Au-PANI glucose biosensor operates as the first generation glucose biosensor. Thus, SAM-PANI monolayer is suitable for selective …
-
Fabrication and Optimization of a 25µm Glucose Sensor
… have been used for over 30 years of glucose biosensor history. Two different types of glucose biosensors were developed using 176um and 25um diameter Pt wire cylindrical microelectrodes. The 176 um Pt wire type microelectrodes were modified with non-conductive polymers and glucose …
-
NANOPILLAR BASED ELECTROCHEMICAL BIOSENSOR FOR MONITORING MICROFLUIDIC BASED CELL CULTURE
… and stable microfluidic electrochemical glucose biosensor to make continuous glucose measurements in cell culture media. The performance of the microfluidic biosensor was enhanced by adding 3D nanopillars to the electrode surfaces. The microfluidic glucose biosensor consisted of three …
Page 1 of 4