Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 344 for “"glucose monitoring"”.

  1. Home Blood Glucose Monitoring

    Home Blood Glucose Monitoring is a videocassette instructional program designed to assist diabetic persons in learning to measure blood glucose levels at home. The program could also be used for the instruction of nursing students or health care agency personnel . The program is presented in three …

    marquette Repository record for Home Blood Glucose Monitoring (opens in a new tab)

  2. Biocompatible Fluorescent Hydrogel Fiber for Glucose Monitoring

    … health complications due to elevated blood glucose levels. This is mainly caused due to lack of insulin secretion by pancreas (Type I) or when the cells in the body become resistant to insulin (Type II). The key for diabetes treatment is regular monitoring and maintenance of blood glucose …

    uconn-diss Repository record for Biocompatible Fluorescent Hydrogel Fiber for Glucose Monitoring (opens in a new tab)

  3. Enhancing Diabetic Patient Continuous Glucose Monitoring Access

    … utilize treatments that require frequent monitoring and medication changes based on their blood sugar results. Continuous Glucose Monitoring (CGM) is more commonly used for diabetes management as time in range is becoming more prevalent to measure diabetes outcomes. Many diabetic patients …

    usfca Repository record for Enhancing Diabetic Patient Continuous Glucose Monitoring Access (opens in a new tab)

  4. Use of Glucose Monitoring Systems in Horses

    Traditional methods of blood glucose monitoring involve obtaining samples for measurement via laboratory methodology or point of care devices and require invasive collection techniques such as capillary stick, venipuncture, or the placement of intravenous catheters. Limitations of traditional …

    vt Repository record for Use of Glucose Monitoring Systems in Horses (opens in a new tab)

  5. Improvements to iontophoresis devices for transdermal glucose monitoring

    Self-monitoring of blood glucose plays a crucial role in diabetes care. Currentmethods apply invasive means, which causes pain and discomfort to the people withdiabetes. Therefore, non-invasive methods are in high demand. Reverse Iontophoresis(RI) is a technique for non-invasive transdermal glucose …

    strathclyde Repository record for Improvements to iontophoresis devices for transdermal glucose monitoring (opens in a new tab)

  6. Non-Invasive Blood Glucose Monitoring Using Electromagnetic Sensors

    Monitoring glycemia levels in people with diabetes has developed rapidly over the last decade. A broad range of easy-to-use systems of reliable accuracies are now deployed in the market following the introduction of the invasive self-monitoring blood glucose meters (i.e., Glucometers) that utilize …

    waterloo Repository record for Non-Invasive Blood Glucose Monitoring Using Electromagnetic Sensors (opens in a new tab)

  7. RF Sensing System for Continuous Blood Glucose Monitoring

    … purpose of this research was to design a blood glucose sensing system based on the induced shift in the resonant frequency of an antenna patch operating in the ISM band (5.725 – 5.875 GHz). The underlying concept is the fact that when a person has variations in their blood glucose levels, the …

    usf Repository record for RF Sensing System for Continuous Blood Glucose Monitoring (opens in a new tab)

  8. Continuous Glucose Monitoring and Diabetes Management During Pregnancy

    Continuous Glucose Monitoring and Diabetes Management During Pregnancy Abstract According to the Scope of Practice, Standards of Practice, and the Standards of Professional Performance for Diabetes Educators, registered nurses play an integral role in the promotion of diabetes self-management …

    usfca Repository record for Continuous Glucose Monitoring and Diabetes Management During Pregnancy (opens in a new tab)

  9. An Investigation of Multimodal Display for Continuous Glucose Monitoring

    Continuous Glucose Monitors (CGM) have helped those struggling with Type 1 Diabetes improve their glycemic control without increasing episodes of hypoglycemia (Gandhi et. al., 2011). However, current implementations of CGMs have a low rate of adoption, as well as a high rate of reduction or …

    umn Repository record for An Investigation of Multimodal Display for Continuous Glucose Monitoring (opens in a new tab)

  10. Continuous glucose monitoring in young and older healthy adults

    The ageing process is characterised by changes in glucose metabolism, sleep, cortisol, vitamin D and chrononutritional aspects (e.g. meal frequency and timing). Continuous glucose monitoring (CGM) can be used to provide information on glycemic variability and control. 34 young (20-35 y.) and 27 …

    cau-kiel Repository record for Continuous glucose monitoring in young and older healthy adults (opens in a new tab)

  11. Non-invasive Glucose Monitoring using Microwave Sensor with Machine Learning

    … chronic condition that occurs when the levels of glucose are high in the blood because the body cannot produce any or enough insulin or use insulin effectively. According to the International Diabetes Federation (IDF), 537 million people are currently living with diabetes. It is very important for …

    waterloo Repository record for Non-invasive Glucose Monitoring using Microwave Sensor with Machine Learning (opens in a new tab)

  12. Patient and physician views of self-testing: blood glucose monitoring

    … laboratory results to aid in the diagnosis and monitoring of disease states. Point-of-care testing (POCT), a sub-sector of medical laboratory services, is completed at the patient’s bedside with the goal of providing clinical laboratory results in a very short time frame to assist caregivers in …

    uoit Repository record for Patient and physician views of self-testing: blood glucose monitoring (opens in a new tab)

  13. Sensing and signal processing for non-invasive blood glucose monitoring

    Remote monitoring is required in several applications and generically, a remote monitoring architecture can be separated into 3 distinct but inter-related layers namely: sensing, signal processing and communications. However, this study focuses on the sensing and signal processing aspects in …

    whiterose Download file for Sensing and signal processing for non-invasive blood glucose monitoring (opens in a new tab)

  14. Continuous Glucose Monitoring for the diagnosis of Gestational Diabetes Mellitus.

    … increasing worldwide. The validity of the oral glucose tolerance test (OGTT) for GDM diagnosis remains contested. Continuous Glucose Monitoring (CGM) could represent a more acceptable and replicable test. Aim of this project was to assess CGM for GDM diagnosis. This PhD thesis is based on five …

    unsw Repository record for Continuous Glucose Monitoring for the diagnosis of Gestational Diabetes Mellitus. (opens in a new tab)

  15. A Non-Enzymatic Continuous Glucose Monitoring System Using Electrochemical Impedance Spectroscopy

    … trial for the development of a continuous glucose monitoring system using electrochemical impedance spectroscopy. Three separate experiments are conducted to determine the effects of electrode surface area on sensing efficacy, the effects of glucose concentration on impedimetric response, …

    texas-state Repository record for A Non-Enzymatic Continuous Glucose Monitoring System Using Electrochemical Impedance Spectroscopy (opens in a new tab)

  16. 45-nm SOI CMOS Bluetooth Electrochemical Sensor for Continuous Glucose Monitoring

    Due to increasing rates of diabetes, non-invasive glucose monitoring systems will become critical to improving health outcomes for an increasing patient population. Bluetooth integration for such a system has been previously unattainable due to the prohibitive energy consumption. However, enabling …

    waterloo Repository record for 45-nm SOI CMOS Bluetooth Electrochemical Sensor for Continuous Glucose Monitoring (opens in a new tab)

  17. Development of a "Self-Cleaning" Encapsulation Technology for Implantable Glucose Monitoring

    … have emphasized the need for continuous glucose monitoring. Optically-based methods are advantageous as they have potential for noninvasive or minimally invasive detection. Fluorescence-based affinity assays, in particular, can be fast, reagentless, and highly specific. Poly(ethylene …

    tamu Repository record for Development of a "Self-Cleaning" Encapsulation Technology for Implantable Glucose Monitoring (opens in a new tab)

Page 1 of 18