Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 344 for “"glucose monitoring"”.
-
Home Blood Glucose Monitoring
Home Blood Glucose Monitoring is a videocassette instructional program designed to assist diabetic persons in learning to measure blood glucose levels at home. The program could also be used for the instruction of nursing students or health care agency personnel . The program is presented in three …
-
Biocompatible Fluorescent Hydrogel Fiber for Glucose Monitoring
… health complications due to elevated blood glucose levels. This is mainly caused due to lack of insulin secretion by pancreas (Type I) or when the cells in the body become resistant to insulin (Type II). The key for diabetes treatment is regular monitoring and maintenance of blood glucose …
-
Enhancing Diabetic Patient Continuous Glucose Monitoring Access
… utilize treatments that require frequent monitoring and medication changes based on their blood sugar results. Continuous Glucose Monitoring (CGM) is more commonly used for diabetes management as time in range is becoming more prevalent to measure diabetes outcomes. Many diabetic patients …
-
Use of Glucose Monitoring Systems in Horses
Traditional methods of blood glucose monitoring involve obtaining samples for measurement via laboratory methodology or point of care devices and require invasive collection techniques such as capillary stick, venipuncture, or the placement of intravenous catheters. Limitations of traditional …
-
Improvements to iontophoresis devices for transdermal glucose monitoring
Self-monitoring of blood glucose plays a crucial role in diabetes care. Currentmethods apply invasive means, which causes pain and discomfort to the people withdiabetes. Therefore, non-invasive methods are in high demand. Reverse Iontophoresis(RI) is a technique for non-invasive transdermal glucose …
-
Non-Invasive Blood Glucose Monitoring Using Electromagnetic Sensors
Monitoring glycemia levels in people with diabetes has developed rapidly over the last decade. A broad range of easy-to-use systems of reliable accuracies are now deployed in the market following the introduction of the invasive self-monitoring blood glucose meters (i.e., Glucometers) that utilize …
-
RF Sensing System for Continuous Blood Glucose Monitoring
… purpose of this research was to design a blood glucose sensing system based on the induced shift in the resonant frequency of an antenna patch operating in the ISM band (5.725 – 5.875 GHz). The underlying concept is the fact that when a person has variations in their blood glucose levels, the …
-
Continuous Glucose Monitoring and Diabetes Management During Pregnancy
Continuous Glucose Monitoring and Diabetes Management During Pregnancy Abstract According to the Scope of Practice, Standards of Practice, and the Standards of Professional Performance for Diabetes Educators, registered nurses play an integral role in the promotion of diabetes self-management …
-
An Investigation of Multimodal Display for Continuous Glucose Monitoring
Continuous Glucose Monitors (CGM) have helped those struggling with Type 1 Diabetes improve their glycemic control without increasing episodes of hypoglycemia (Gandhi et. al., 2011). However, current implementations of CGMs have a low rate of adoption, as well as a high rate of reduction or …
-
Continuous glucose monitoring in young and older healthy adults
The ageing process is characterised by changes in glucose metabolism, sleep, cortisol, vitamin D and chrononutritional aspects (e.g. meal frequency and timing). Continuous glucose monitoring (CGM) can be used to provide information on glycemic variability and control. 34 young (20-35 y.) and 27 …
-
Non-invasive Glucose Monitoring using Microwave Sensor with Machine Learning
… chronic condition that occurs when the levels of glucose are high in the blood because the body cannot produce any or enough insulin or use insulin effectively. According to the International Diabetes Federation (IDF), 537 million people are currently living with diabetes. It is very important for …
-
Patient and physician views of self-testing: blood glucose monitoring
… laboratory results to aid in the diagnosis and monitoring of disease states. Point-of-care testing (POCT), a sub-sector of medical laboratory services, is completed at the patient’s bedside with the goal of providing clinical laboratory results in a very short time frame to assist caregivers in …
-
Sensing and signal processing for non-invasive blood glucose monitoring
Remote monitoring is required in several applications and generically, a remote monitoring architecture can be separated into 3 distinct but inter-related layers namely: sensing, signal processing and communications. However, this study focuses on the sensing and signal processing aspects in …
-
Continuous Glucose Monitoring for the diagnosis of Gestational Diabetes Mellitus.
… increasing worldwide. The validity of the oral glucose tolerance test (OGTT) for GDM diagnosis remains contested. Continuous Glucose Monitoring (CGM) could represent a more acceptable and replicable test. Aim of this project was to assess CGM for GDM diagnosis. This PhD thesis is based on five …
-
A Non-Enzymatic Continuous Glucose Monitoring System Using Electrochemical Impedance Spectroscopy
… trial for the development of a continuous glucose monitoring system using electrochemical impedance spectroscopy. Three separate experiments are conducted to determine the effects of electrode surface area on sensing efficacy, the effects of glucose concentration on impedimetric response, …
-
45-nm SOI CMOS Bluetooth Electrochemical Sensor for Continuous Glucose Monitoring
Due to increasing rates of diabetes, non-invasive glucose monitoring systems will become critical to improving health outcomes for an increasing patient population. Bluetooth integration for such a system has been previously unattainable due to the prohibitive energy consumption. However, enabling …
-
Development of a "Self-Cleaning" Encapsulation Technology for Implantable Glucose Monitoring
… have emphasized the need for continuous glucose monitoring. Optically-based methods are advantageous as they have potential for noninvasive or minimally invasive detection. Fluorescence-based affinity assays, in particular, can be fast, reagentless, and highly specific. Poly(ethylene …
Page 1 of 18