Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"glulam beam"”.
-
Vibration Behaviour of Glulam Beam-and-Deck Floors
… performance of glued-laminated-timber (glulam) beam-and-deck floor systems. Such floors are applicable in non-residential buildings having spans up to about 10 m. The primary goal was to use test and numerical analysis methods to investigate how construction variables (e.g. beam span, …
-
Experimental evaluation of the ulag glulam beam simulation program
… study on the bending capacity of glued-laminated beams was undertaken to facilitate the verification of the stochastic finite element beam simulation program ULAG (Ultimate Load Analysis of Glulam). For the material data base, 600 tension and stiffness tests were done on two different grades of …
-
Strength and reliability analyses of glulam beam-column moment resisting connections
… investigates the rotational performance of glulam beam–column bolted moment connections through full-scale experimental testing, finite element (FE) modeling, and structural reliability analysis. A total of twenty-five full-size glulam bolted moment connections in three configurations were …
-
Modelling strength and stiffness of glued-laminated timber using machine stress rated lumber
… MSR lumbers, different sizes and layups of glulam beams have been built and the effect of beam sizes and layups on the strength of glulam beams has been simulated. The results obtained from glulam beam simulation showed that the beam sizes and layups did have significant effect on the beam …
-
Composite action in mass timber floor and beam systems connected with self-tapping wood screws
… This thesis focuses on studying composite T-beams, connecting Spruce-Pine-Fir Cross Laminated Timber (CLT) panels and Douglas-Fir Glued-Laminated timber (glulam) beams. In this study, three different types of self-tapping wood screws (ASSY SK, ASSY Ecofast, and ASSY VG), inserted at different …
-
Experimental and numerical investigation of human-induced vibration performance in mass timber office buildings
… modulus of concrete, shear stiffness of the glulam beam-to-CLT and CLT-to-concrete connectors, and the stiffness of the beam-to-beam connections (whether fixed or pinned) are investigated quantitatively. The study highlights the importance of including columns, adjacent bays, and connections …
-
Fire performance of concealed wood-steel-wood connections with perpendicular to grain reinforcement
… used for this study were fire-protected glulam beam-to-column reinforced concealed connections loaded perpendicular-to-grain in flexure bending. Eight (8) full-scale fire tests were conducted involving four different connection configurations. The load ratios applied during fire testing …
-
Adhesive Joints in Timber Engineering. Modelling and Testing of Fracture Properties
… to the strength of finger-joints, laminated beams and glued-in rods for timber structures. In the experimental studies, the complete stress-displacement response of small specimens, particularly their fracture softening behaviour beyond peak stress, was recorded. A major outcome from the …
-
Detection and assessment of wood decay – glulam beams and wooden utility poles
… and ultrasonic inspection methods on wooden glulam beams and utility poles. All beams and poles examined where composed of Douglas-fir. The report begins with a description of the structure of trees, the mechanical behavior of wood subjected to rot, and current utility pole inspection …
-
Application of Ductile Yield Link in Glulam Moment Connections
Wood beam-column connections have traditionally been designed as simple shear connections, ignoring their potential moment capacity. A major reason for not utilizing such moment connections is linked to the brittle limit states that wood components exhibit. The purpose of this research was to …
-
New constructions of glulam beams in Canada
An optimized 24f glulam beam lay-up has been investigated with a series of laboratory testing and computer modeling. The basic ideas of these assessments are to increase the efficient use of timber resource in the glulam construction with integration of reliability based procedures to characterize …
-
Fire Performance of Hybrid Timber Connections
… fire performance of hybrid connections between a glulam beam and a steel column by conducting full scale tests and finite element modeling. The experimental part of this research consisted of a series of full-scale tests conducted in compliance with CAN/ULC-S101. Three different types of …
-
A framework for fire performance assessment of mass timber structures : numerical and machine-learning approaches
… compartment fire tests. Subsequently, for glulam members exposed to fire, an equivalent section temperature (EST) is proposed to simplify the non-uniform temperature field of the section into a single representative temperature that captures the strength/stiffness degradation. The modelling …
-
Structural Behaviour of Pre-Engineered Beam-Hanger Connections for Mass Timber and Hybrid Mass Timber-Steel Structures
… structural safety. The connections between beams and columns in modern mass timber construction are often facilitated using pre-engineered beam-hanger connections, which consist of interlocking metal brackets that are fastened to the timber elements using self-tapping screws. While these …
-
Assessment and Optimisation of CFRP Reinforced Glulam Beams - A feasibility study in design stage reinforcement configurations for pedestrian bridge applications
… the reinforcement in Glued Laminated Timber (Glulam) in the production stage, the structure can be designed with higher capacity or smaller dimensions. Further on, embedding the CFRP laminas gives a better protection towards moisture and UV-radiation, which otherwise might lead to chemical …
-
Serviceability Design of Long-Span Timber Beams Considering Semi-Rigid Beam-Column Connections
… partial rotational restraint provided by real beam-column connections. This simplification often results in overly conservative designs, inefficient material use, and underutilisation of structural capacity. Addressing this gap, this thesis investigates the influence of semi-rigid connection …
-
Development, Evaluation and Implementation of Sensor Techniques for Bridges Critical to the National Transportation System
… smart timber bridge made of glued laminated (glulam) stringers and a transverse glulam deck. Both stock and custom fiber optic sensor packages were implemented to quantify the structural response. The first of multiple phases of this national five year plan includes the development of an …
-
"Fit Body" Sporting Centre
Diplomová práce zpracovává dokumentaci pro realizaci novostavby multifunkčního sportovního centra. Objekt je navržen jako dvoupodlažní s vnějším zateplovacím systémem ETICS. Objekt je navržen dle požadavků příslušných právních předpisů. Objekt splňuje hodnoty nízkoenergetického standartu. Budova je …
-
Investigation and Optimization of Connections in Timber Assemblies Subjected to Blast Loading
… increase in dynamic peak load. Full-scale glulam specimens with bolted connections designed to yield via wood crushing and bolt bending performed better than those with overdesigned connections. Bolted connections which failed in splitting led to premature failure of the glulam assembly. …