Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 112 for “"goniometry"”.
-
Critical study of contact angle goniometry
In this thesis contact angle goniometry as a characterization method for solid surface wettability is critically examined. Contact angle goniometry is a powerful and versatile tool for measuring wetting properties, facilitating the study of microscale surface properties by macroscopic an optical …
-
Spectrodirectional ground-based remote sensing using dual-view goniometry: field BRF retrieval and assessment of the diffuse irradiance distribution in spectrodirectional field measurements
… the field or in a laboratory environment. Field goniometry has the advantage that the target is left in its natural environment, including the natural illumination by the sun. The major disadvantage, however, is that atmospheric effects and undesired time variations of the illumination have to be …
-
The validation and use of a three dimensional goniometry system to investigate lumbar motion in healthy subjects and low back pain patients undergoing manual mobilisation
This study of lumbar spinal kinematics in healthy subjects and low back pain patients had three defined aims: The first aim was to investigate the lumbar spinal kinematics in healthy subjects during 6 gross movements and 4 functional activities using a newly developed electromagnetic measurement …
-
A Small Acoustic Goniometer for General Purpose Research
… many research projects. In particular, acoustic goniometry allows researchers to determine the source of an event based solely on the sound it produces. The vast majority of the acoustic goniometry research projects used custom hardware targeted to the specific application under test. …
-
Dynamics of Magnetic Droplets on Liquid-Repellent Surfaces
… ferrofluids and the limitations of contact angle goniometry are experimentally investigated, and novel field-induced instabilities and ferrofluid-based wetting characterisation methods are demonstrated. Publication I is an in-depth comparative analysis of two ferrofluids with electrostatic and …
-
Rankos trifalangių pirštų grafinės popieriaus juostų ir standartinės goniometrijos tarpusavio pakeičiamumas ir jo reikšmė savityrai /
… could be a quick alternative to the standard goniometry and a means for self-evaluation. Reliability of the paper strip technique has not been explored. Methods This research compared reliability characteristics of repeated measurements obtained with both tools by employing (1) 24 healthy …
-
Rankos trifalangių pirštų grafinės popieriaus juostų ir standartinės goniometrijos tarpusavio pakeičiamumas ir jo reikšmė savityrai /
… could be a quick alternative to the standard goniometry and a means for self-evaluation. Reliability of the paper strip technique has not been explored. Methods This research compared reliability characteristics of repeated measurements obtained with both tools by employing (1) 24 healthy …
-
Reconstruction of the Tranter’s Creek Vessel and Investigation into Its Sinking
… down to four indicates strongly that not only is goniometry sufficiently accurate in low-to-zero visibility conditions, but that hull reconstructions from partial, unraised archaeological remains are useful as well. Goniometry would be particularly good for rescue archaeology on low-visibility …
-
The First Attachment and Post-Functionalization of Polybutadiene and Thio-Click Functionalized Polybutadiene on H-Terminated Si(111)
… Surfaces were characterized with contact angle goniometry, spectroscopic ellipsometry, X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and atomic force microscopy (AFM).
-
Micro- and nanoscale features of insect cuticle and their impacts on wetting, friction, and optical properties
… with scanning electron microscopy (SEM). Goniometry was used to determine their wettability. SEM and goniometry revealed that there is a relationship between fly wing structures and wetting – those with hierarchies of nano- and microscale structures are able to achieve superhydrophobicity. …
-
Feasibility of Ellipsometric Sensor Development for Use During PECVD SiOx Coated Polymer Product Manufacturing
… parameters. Abeles’ method and monochromatic goniometry were attempted; however, the results had to be discarded due to irrecoverable errors discovered in the reflectance measurement. X-ray photoelectron spectroscopy (XPS) data provided by NS3 showed the deposited SiOX films to be homogeneous …
-
Spectroelectrochemical analysis of self-assembled monolayers on gold
… compared favorably with the currently-used goniometry method because the IRRAS method was faster, less prone to operator bias, and provided structural information.
-
Development of a mobile technology system to measure shoulder range of motion
… of interventions. Current clinical methods of goniometry and visual estimation require an experienced user and suffer from low inter-rater reliability. More sophisticated techniques such as optical or electromagnetic motion capture exist but are expensive and restricted to a specialised …
-
The Effects of Thermostim Instrument Assisted Soft Tissue Mobilization and Superficial Heat on Range of Motion of the Hamstrings and Perceived Patient Comfort
… post-treatment range of motion was measured by goniometry with the hip flexed to 90° with passive knee extension. A statistically significant difference existed between pre- and post-treatment range of motion for both treatment times. There was no significant difference between groups due to the …
-
The Functional Relationship Between the Sacroiliac Joint and the Occipito-Atlanto-Axial-Joint Complex: Pilot Study
… for sacroiliac joint dysfunction and a universal goniometry measurement of cervical range of motion. This study was conducted at a state university. Fifty six participants volunteered, and twenty seven completed the first measurement and seventeen completed the second measurement. SPSS 20 was …
-
Fizinių pratimų poveikis senyvo amžiaus asmenims patyrusiems viršutinių galūnių lūžius savarankiškumui /
… dyna-mometry - to assess muscle strength, and goniometry - to measure amplitudes. Conclusions: 1. Analysing the data of people who have suffered upper limb fractures, it was found that most of them live in the city, in an apartment and are unemployed. 2. Independence at work was studied using …
-
CORRELAZIONE TRA LUNGHEZZA MUSCOLARE E LESIONE MIO TENDINEA DEI MUSCOLI ISCHIO CRURALI NELLO SPORTIVO
… 28,5 years. Clinical measures have been done by goniometry of knee ROM and muscular length have been evalued sonographically. All measures have been compared with a control healthy population of athletes. The results of the study showed a significative correlation between ROM and muscular length …
-
Plasma polymerized hydrogel thin films for applications in sensors and actuators
… infrared spectroscopy (FTIR). Contact angle goniometry and quartz crystal microbalance with dissipation monitoring were used to confirm the existence of a hydrophilic-hydrophobic transition in plasma polymerized NIPAAm thin films, analogous to the lower critical solution temperature (LCST) …
-
SURFACE MODIFICATION OF SOLID SUBSTRATES THEIR FABRICATION, CHARACTERIZATION, AND APPLICATIONS
… by characterization using XPS, contact angle goniometry, PM-IRRAS, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. The filamentization was designed to improve efficiency by reducing AC loss.
-
Analysis of Electrospun Tβ4 Coated Scaffolds: A Tissue Engineering Study
… was collected using multiple techniques such as goniometry and cell viability assays. The data was analyzed using either paired t-tests or analysis of variance (ANOVA). The analyzes compared treatments to determine Tß4's effect on cell proliferation and integration. Though the results did not …
Page 1 of 6