Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"gradient coil"”.

  1. Improvements in Diffusion Weighted Imaging Through a Composite Body and Insert Gradient Coil System

    … brain damage to potential prediction of stroke. Gradient coil and signal-to- noise ratio (SNR) constraints limit spatial resolution, accuracy, and scan time in DMRI. Achieving high b-values (measures of a scan's sensitivity to diffusion) often require scans with long diffusion gradient pulses, …

    byu Repository record for Improvements in Diffusion Weighted Imaging Through a Composite Body and Insert Gradient Coil System (opens in a new tab) Download PDF for Improvements in Diffusion Weighted Imaging Through a Composite Body and Insert Gradient Coil System (opens in a new tab)

  2. Highly Parallel Magnetic Resonance Imaging with a Fourth Gradient Channel for Compensation of RF Phase Patterns

    A fourth gradient channel was implemented to provide slice dependent RF coil phase compensation for arrays in dual-sided or "sandwich" configurations. The use of highly parallel arrays for single echo acquisition magnetic resonance imaging allows both highly accelerated imaging and capture of …

    tamu Repository record for Highly Parallel Magnetic Resonance Imaging with a Fourth Gradient Channel for Compensation of RF Phase Patterns (opens in a new tab)

  3. Reducing Acoustic Noise in MRI Scanners

    … of generalized radiation impedances of gradient coil ducts with perforated panel inserts were developed and the effects of the perforated panel inserts on the acoustic noise in the duct were discussed. The possibility of using micro-perforated panel (MPP) absorbers in MRI scanners to …

    queens Repository record for Reducing Acoustic Noise in MRI Scanners (opens in a new tab)

  4. Development and applications of a highly flexible nonlinear spatial encoding system for magnetic resonance imaging

    … to design, implement and test a shielded matrix gradient coil for magnetic resonance imaging (MRI).<br><br>The design process addressed gradient strength, flexibility, magnetic shielding, cooling, electrical decoupling, balance of force and torque and patient safety. These demands were fulfilled …

    freiburg-diss Repository record for Development and applications of a highly flexible nonlinear spatial encoding system for magnetic resonance imaging (opens in a new tab)

  5. Applications of rheo-NMR-microscopy to complex fluids : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Physics at Massey University

    … polymer side branch length, were also studied. Gradient coil developments are also described in detail. Linearity, homogeneity and screening conditions are investigated for a transverse quadrupole-target-field gradient coil. The need for large gradients are discussed with the implications to …

    massey Repository record for Applications of rheo-NMR-microscopy to complex fluids : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Physics at Massey University (opens in a new tab)

  6. Indirect Detection of Axonal Architecture With Q-Space Imaging

    … morphology. First, a custom-built high-amplitude gradient coil was used to address the limitations in the maximum gradient amplitude available with commercial systems. Second, to understand the relationship between axon morphology and QSI, simulations were used to investigate the effects of the …

    penn Repository record for Indirect Detection of Axonal Architecture With Q-Space Imaging (opens in a new tab)

  7. NMR measurement of diffusion in liquids by the pulsed field gradient technique

    … of diffusion measurement by the pulsed field gradient, technique is described. A 9-T-18 spin-echo sequence is used with one gradient pulse located on each side of the 18 rf pulse. Information on restricted diffusion is obtained by varying the measuring time, which is determined by the …

    rice Repository record for NMR measurement of diffusion in liquids by the pulsed field gradient technique (opens in a new tab)

  8. Enhancements to Uniformity of Magnetic Fields at the SNS nEDM Experiment

    … cell. The Magnetic Shield Enclosure (MSE) coil provides the required field. However, the superconducting shield distorts the MSE field. This thesis discusses a magnetic cloak for the nEDM@SNS experiment that can restore the MSE field uniformity and cos theta coils designed to test the …

    uky-thes Repository record for Enhancements to Uniformity of Magnetic Fields at the SNS nEDM Experiment (opens in a new tab)

  9. Investigation of Magnetic Particle Imaging: Localization Along One Dimension

    … a guide and tips on how to decouple the transmit coil and receive coil. The section on tests and results analyzes the specification of the MPI system by characterizing the gradient coil, analyzing the detection limit for the relaxometry component of the system, and the sensitivity and resolution …

    tamu Repository record for Investigation of Magnetic Particle Imaging: Localization Along One Dimension (opens in a new tab)

  10. Magnetic Resonance Imaging of Ultrasound Fields for Visualization and Measurement of Pressure Amplitudes

    … a ballistic gel medium by using an external gradient coil to encode the pressure field in a way that can be read and quantified using an MRI scanner. We describe the methods and the results pertaining to visualizing a pressure field. The setup was able to capture pressure field images and …

    byu Repository record for Magnetic Resonance Imaging of Ultrasound Fields for Visualization and Measurement of Pressure Amplitudes (opens in a new tab) Download PDF for Magnetic Resonance Imaging of Ultrasound Fields for Visualization and Measurement of Pressure Amplitudes (opens in a new tab)

  11. One dimensional electron spin imaging for single spin detection and manipulation using a gradient field

    … ESR imaging based on the use of high field gradients. In the present research, subwavelength single molecule imaging is demonstrated by using the optically detected ESR technique and the optically detected electron spin echo envelope modulation (ESEEM) technique. Ultra fast Rabi nutation …

    tamu Repository record for One dimensional electron spin imaging for single spin detection and manipulation using a gradient field (opens in a new tab)

  12. Correlation of Magnetic Resonance images of the human temporomandibular joint with gross and microscopic anatomy

    … factors such as magnetic field strength, gradient coil strength, software and surface coils to achieve a high quality image. The small number of false diagnoses in this study were consistently related to underestimation of the pathologic conditions. All of the false diagnoses were false …

    adelaide Repository record for Correlation of Magnetic Resonance images of the human temporomandibular joint with gross and microscopic anatomy (opens in a new tab)

  13. Analysis of Metallic Shielding for Reduction of RF Induced Heating of Electrode During MRI for Active Implants

    … components of MRI systems- static magnet, RF coil, and a gradient coil- interact with the implantable medical devices. These interactions can cause force, torque, device vibrations and RF-induced heating. Among all these potential hazards is the heating caused by the RF electromagnetic field. …

    purdue-thes Repository record for Analysis of Metallic Shielding for Reduction of RF Induced Heating of Electrode During MRI for Active Implants (opens in a new tab)

  14. Classical Transport in Disordered Systems

    … a phase ϕ to the spins using magnetic field gradients. The main limitation for probing short diffusion lengths L(t) = 1 µm with magnetic resonance is the requirement to encode and decode the phase ϕ in very short time intervals. Therefore, to probe such displacements a special probe was …

    cuny-grad Repository record for Classical Transport in Disordered Systems (opens in a new tab)

  15. On the employment of matrix gradient coils for novel spatial encoding and magnetic field shimming in magnetic resonance imaging

    … Therefore in the recent past so-called matrix gradient coils, which consist of a large number of small coils, were introduced. The current in each such coil element can be adjusted individually, and the final field shape is given by the superposition of the fields of all coil elements. Such an …

    freiburg-diss Repository record for On the employment of matrix gradient coils for novel spatial encoding and magnetic field shimming in magnetic resonance imaging (opens in a new tab)

  16. Automated methods for gradient and shim coil design for magnetic resonance imaging

    The design of gradient and shim coils for MR imaging, as central hardware components for <br>signal encoding and thus image generation, is a complex and time-consuming engineering task. From the choice of support geometry to the optimization of current density to the preparation of the final, …

    freiburg-diss Repository record for Automated methods for gradient and shim coil design for magnetic resonance imaging (opens in a new tab)

Page 1 of 2