Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 147 for “"gradient echo"”.
-
Quantum optical storage and processing using raman gradient echo memory
… at a later time. This is done by applying a gradient of magnetic field along the atomic ensemble that is the basis for our optical memory. To recall the light we flip the sign of the gradient field. This kind of reversible absorption is called photon echo, hence the name of our scheme: The …
-
QUANTITATIVE T2 MAPPING USING ACCELERATED 3D STACK-OF-SPIRAL GRADIENT ECHO READOUT
… to collect several k-space data at different echo times, which leads to long scan time. The purpose of this thesis is to develop a rapid and accurate T2 mapping protocol with 3D high-resolution and whole- brain coverage using optimized spiral acquisition, accelerated reconstruction, and model …
-
Timing the State of Light with Anomalous Dispersion and a Gradient Echo Memory
… retrieval of multiplexed optical signals in a Gradient Echo Memory (GEM) at relevant four-wave mixing frequencies in 85Rb. Temporal multiplexing capabilities are demonstrated by storing multiple classical images in the memory simultaneously and observing the expected first-in last-out order of …
-
On Nature of the Gradient Echo MR Signal and Its Application to Monitoring Multiple Sclerosis
… they have not penetrated to clinical arena yet.Gradient Echo Plural Contrast Imaging: GEPCI) developed in our laboratory is a post processing technique based on multi-echo gradient echo sequence. It offers basic contrasts such as T1W images and T2* maps obtained from magnitude of GEPCI signal, …
-
Storage and manipulation of optical information using gradient echo memory in warm vapours and cold ensembles
… one memory. This thesis focuses on extending the gradient echo memory (GEM) scheme, which shows great promise due to the high efficiencies achieved (87%) [4]. GEM has also been used to demonstrate temporal compression and stretching of pulses, as well as a capacity to arbitrarily resequence stored …
-
Tissue Damage Quantification in Alzheimer's Disease Brain via Magnetic Resonance Gradient Echo Plural Contrast Imaging (GEPCI)
… developed in Yablonskiy’s lab is based on the Gradient Echo Plural Contrast Imaging (GEPCI) protocol, which provides quantitative in vivo measurements of transverse relaxation properties of the tissue water 1H spins as determined from the gradient echo MRI signal. The measurements are corrected …
-
Gradient echo-based quantitative MRI of human brain at 7T : Mapping of T1, MT saturation and local flip angle
… T2) also needs to be accounted for.Here, spoiled gradient-recalled echo (GRE) techniques are employed to map (primarily) two structural MR parameters, i.e. the longitudinal relaxation time (T1) and the magnetization transfer (MT) saturation (MTsat). Because of its influence at UHF, emphasis is …
-
High performance solid state quantum memory
… storage times. The technique used is an optical "gradient echo", an optical equivalent to the long studied gradient echo technique used in Nuclear Magnetic Resonance (NMR). Aside from it's practicality for demonstrations, a gradient-echo also offers a powerful handle for manipulating stored light. …
-
Positive Contrast Magnetic Resonance Imaging with Multifunctionalised Magnetic Nanoparticles
… contrast imaging. The most prominent are GRadient-echo Acquisition for Superparamagnetic particles with Positive contrast (GRASP), Inversion Recovery with ON-resonant water suppression (IRON) and Susceptibility Gradient Mapping (SGM). <br/><br/>Four novel SPIONs of different sizes, …
-
Temperature mapping of particles during aseptic processing via magnetic resonance imaging
… processing were studied. A variable flip angle gradient echo sequence was initially tested. With this sequence T1 maps were obtained from two images acquired in sequence with a total imaging time of approximately 25 seconds. With a T1 vs temperature calibration, temperature determinations were …
Page 1 of 8