Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 9 of 9 for “"gridded energy analyzer"”

  1. Development of a Gridded Energy Analyzer for Measurement of the Mochi Experiment Ion Energy Distribution

    … This thesis describes the development of a gridded energy analyzer (GEA), the ultimate goal of which is to provide initial measurements of Mochi’s ion energy distribution. The concept of the Mochi.GEA is to start with the simplest possible design and make necessary improvements based on …

    washington Repository record for Development of a Gridded Energy Analyzer for Measurement of the Mochi Experiment Ion Energy Distribution (opens in a new tab)

  2. Measurement of plasma parameters in the exhaust of a magnetoplasma rocket by gridded energy analyzer and emissive Langmuir probe

    … tens of kilometers per second. In this device, energy is imparted to the plasma ions by two mechanisms: ion cyclotron resonant heating (ICRH), and acceleration in an ambipolar electric field. Measurements from two different electrostatic probes are combined to determine how much each mechanism …

    rice Repository record for Measurement of plasma parameters in the exhaust of a magnetoplasma rocket by gridded energy analyzer and emissive Langmuir probe (opens in a new tab)

  3. Determination of Ionization Fraction and Plasma Potential in a DC Magnetron Sputtering System Using a Quartz Crystal Microbalance and a Gridded Energy Analyzer

    Made available in DSpace on 2017-07-06T18:48:17Z (GMT). No. of bitstreams: 3 Green_Karyn_M_MS.pdf: 35887684 bytes, checksum: 4d8ec8bef5ab4e9e6aabee4e3ff410a5 (MD5) Green_Karyn_M_MS_ABS.pdf: 507343 bytes, checksum: 0d504c63e61c048bbb16c0ee4bce83fa (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Determination of Ionization Fraction and Plasma Potential in a DC Magnetron Sputtering System Using a Quartz Crystal Microbalance and a Gridded Energy Analyzer (opens in a new tab)

  4. Diagnostics for ionized physical vapor deposition chambers

    … designed and developed. The sensor is a combined gridded energy analyzer (GEA) and a quartz crystal microbalance (QCM), with a high aspect ratio collimator in place of the normal electron repeller grid for angular measurement distribution measurements. The collimator is made of copper elements …

    uiuc Repository record for Diagnostics for ionized physical vapor deposition chambers (opens in a new tab)

  5. Interaction of supra-thermal ions with turbulence in a magnetized toroidal plasma

    … To detect the fast ions a specially designed gridded energy analyzer was used. The electron energy distribution function was obtained to demonstrate the efficiency of the detector. The experiments with the fast ion beam were conducted in different plasma regions of TORPEX. In the third part of …

    epfl Repository record for Interaction of supra-thermal ions with turbulence in a magnetized toroidal plasma (opens in a new tab)

  6. Formation and extraction of a dense plasma jet from a helicon-plasma-injected inertial electrostatic confinement device

    … measured by a combination of a Faraday cup and a gridded energy analyzer (GEA). The Faraday cup also included a temperature sensor for collection of thermal power measurements used to compute the efficiency of the IEC device in coupling power into the jet. The GEA allowed for measurement of the …

    uiuc Repository record for Formation and extraction of a dense plasma jet from a helicon-plasma-injected inertial electrostatic confinement device (opens in a new tab)

  7. Plasma diagnostics and ITO film deposition by RF-assisted closed-field dual magnetron system

    … with the RF enhancement and utilize the ion energy instead of thermal energy to facilitate the ITO film growth. The closed-field unbalanced magnetrons create a plasma in the intervening region rather than confine it near the target, thus achieving a large-area processing capability. An …

    uiuc Repository record for Plasma diagnostics and ITO film deposition by RF-assisted closed-field dual magnetron system (opens in a new tab)

  8. Characterization of Magnetron-Sputtered Partially Ionized Deposition as a Function of Metal and Gas Species

    Made available in DSpace on 2017-07-06T18:42:14Z (GMT). No. of bitstreams: 3 Allain_Monica_M_C_MS.pdf: 58019977 bytes, checksum: 4321fbe9df3b2ff27db7a25168c1475e (MD5) Allain_Monica_M_C_MS_ABS.pdf: 548280 bytes, checksum: e229bd5e9fd6338bb6b4380fdd932ba4 (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Characterization of Magnetron-Sputtered Partially Ionized Deposition as a Function of Metal and Gas Species (opens in a new tab)

  9. Comparison of high power impulse magnetron sputtering and modulated pulsed power sputtering for interconnect metallization

    … (IF) are measured on the substrate level using a gridded energy analyzer (GEA) combined with a quartz crystal microbalance (QCM). Up to 60% has been achieved using a 200 Gauss magnetic field configuration, much higher than the DC magnetron sputtering. It basically increases with higher charging …

    uiuc Repository record for Comparison of high power impulse magnetron sputtering and modulated pulsed power sputtering for interconnect metallization (opens in a new tab)