Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"gross floor area"”.
-
Energy performance of data centres in Singapore
… Power demands and energy consumptions per unit gross floor area of data centres are significantly higher than those of commercial office spaces in Singapore. Secondly, over-designed power demands, over-sizing of HVAC and UPS systems, low occupancy rate of gross floor area, poor layout of IT …
-
Integrating residential heating and cooling flexibility into operational energy system optimization
… these correspond to 0.16–0.87 C/m2 of heated gross floor area per year, depending on the weather year as well as the numbers and types of flexible buildings. Most of the savings were thanks to dedicated storage assets like domestic hot water storage tanks or batteries instead of the thermal …
-
Form Follows Forecast: Monte Carlo Based Feasibility Analysis of Architectural Partis
… that reduce architecture to scalar inputs: gross floor area, story count, cost per square foot, rent, and exit value, among others. These variables are necessary, but they are largely blind to geometry. This thesis proposes an abstracted proxy framework for making the architectural parti …
-
Trip generation characteristics of rural clinics in West Virginia
With the decreasing number of hospitals in rural areas, more rural clinics are being established to meet the health care needs in rural areas. Rural clinics are small health care facilities that serve the primary care needs of rural areas. There are currently no published trip generation rates …
-
House of performance : an indoor-outdoor venue for amplified live music
… storey public assembly building, the maximum gross floor area is 275 m2 (2960 ft2) and the longest unsupported span is 9 m (29’–6”). The HOP has been designed to fit within these guidelines.
-
A PARAMETRIC ENERGY EVALUATION OF PUBLIC HOUSING DESIGN IN SINGAPORE
… orientation of the building, whilst keeping the floor plan area and Gross floor area (GFA) consistent. They are then evaluated for energy demand. 2. [Urban stage] Various Urban layouts of varying the block heights and block separations, whilst keeping the density or Floor Area Ratio (FAR) and …
-
Dwelling densification and "greenness": Hong Kong’s high-density housing and resource conservation
… of estates which are characterized by large site area measured in hectares and towers of 30-40 storeys. The current densities are 2000- 4000 residents per hectare of net site area, plot ratio of 5 and above, 1-2 square metres of communal open space per resident, and 15-20 square metres of gross …
-
A GIS- Based Material Stock-Flow Analysis of Antigua & Barbuda through the lens of the built and socio-economic environment
… building size, (material intensity, number of floors, and the gross floor area) as a means to conduct a material stock analysis. For 2004 the total MS in buildings was estimated at 4,698 kilotonnes (kt), equivalent to 58.5 tonnes per capita. The main construction material of the MS consisted of …
-
Transit-Oriented Development (TOD) for Urban Sustainability: A Comparative Case Study of Beijing and Shenzhen, China
… per capita”, “construction land per capita”, “area of roads per capita” and “GDP per acre”; while Beijing showed more positive effects than Shenzhen on the indicators of “urban residential gross floor area per capita” , “passengers traffic”, and “number of public vehicles”. For the economy …
-
Developing energy-loss test techniques for large buildings.
… envelope. For all non-domestic buildings with a gross floor area of greater than 1000m[2] an air leakage test would be required in accordance with CIBSE TM 23:2000 to prove that the construction was reasonably airtight. The improvements made in the thermal performance of building materials have …
-
Modelling building construction speed by using linear regression analysis, artificial neural networks and n-dimensional finite elements
… variables related to construction costs, gross floor area (GFA), number of floors, and the type of facility were selected to analyse their influence on the duration of the construction process. Additionally, and since that there is no general agreement in the literature regarding which is …
-
Analýza developerského projektu na výstavbu administrativního objektu v Brně
Cílem této diplomové práce je stanovit proveditelnost a výnosnost developerského projektu na konkrétním pozemcích v Brně. Do řešení problému byla zahrnuta, jak část legislativní, která stanovila možnosti využití pozemků se zaměřením na změnu územního plánu, tak část finanční, která v projektové …