Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 51 for “"ground fault"”.
-
ADAPTIVE GROUND FAULT PROTECTION FOR A DISTRBUTION NETWORK
… thesis includes the investigations for setting ground overcurrent relays in a distribution system and changing the settings to adapt to the operating conditions of the system. Four software modules were developed for this purpose and were tested using a personal computer. The results reported in …
-
Ground fault detection for flexible high voltage power systems
… within the high voltage power system, such as ground fault detection circuits, are being required to operate robustly in a high voltage power system that is exposed to electrical noise and significant variation in common mode impedance characteristics.This paper explores four different ground …
-
Design and Development of Magnetoelastic Resonators for PV Ground Fault Detection
… nickel-iron-cobalt alloy resonator for ground fault detection applications, specifically in photovoltaic systems. The electrodeposition technique will be used to fabricate the proposed resonator as it enables a precise manufacturing process. It allows for better control and optimization …
-
ACTIVE CURRENT INJECTION METHOD FOR LIMITING GROUND FAULT CURRENT HARMONICS IN UNDERGROUND COAL MINES
Current practice in U.S. underground coal mine high-voltage distribution systems is to attempt to limit ground fault current to 25 Amperes and de-energize the circuit at 10 Amperes. However, the significant amount of system capacitance due to the use of shielded cables can cause ground fault …
-
Analysis and Control of VSC Based HVDC System under Single-Line-to-Ground Fault Conditions
… conditions, especially under single-line-to-ground (SLG) fault, is a key requirement.</p> <p>This dissertation deals with the development of a fault handling strategy, which helps HVDC systems achieve continuous energy supply and desired operation performance under temporary SLG fault …
-
Modeling and Experimental Verification of Adaptive 100% Stator Ground Fault Protection Schemes for Synchronous Generators
… focusing on a variety of synchronous generator faults have already been proposed and are still modified and developed to further enhance the quality of protection. In this thesis, synchronous generator stator windings to ground fault is studied as one of the most common and crucial faults in …
-
Development and Prototyping of a Ground Fault Circuit Interrupter for 3-Phase 480 Volt Systems
Ground Fault Circuit Interrupter (GFCI) technology was first introduced in the NEC in 1971, yet four decades later the technology has not been introduced to a great extent outside of the home environment. This thesis introduces the difficulties encountered in low-voltage three phase ground fault …
-
Improvement of Ground-Fault Relaying Selectivity through the Application of Directional Relays to High-Voltage Longwall Mining Systems
… systems. Simulations show that during a line-to-ground fault, the larger system capacitance can cause a situation where the ground current sensed by the ground-fault relays in unfaulted circuits is greater than the mandated ground-fault relay pick-up setting. Simulations show that ground-fault …
-
Transient overvoltages caused by a monopolar fault on a bipolar dc overhead line with dedicated metallic return
… thesis deals with overvoltages caused due to a ground fault on pole conductor in an overhead bipolar Line Commutated Converter (LCC) HVdc system with a Dedicated Metallic Return (DMR). In HVdc systems with earth return, when a fault occurs, one pole may be lost causing the system to operate in …
-
Electromagnetic Analysis of Stator Ground Faults in Synchronous Generators
There are many stator ground faults protection schemes available in the industry. These schemes relatively perform well in detecting the faults in the stator winding. The protection of the neutral point vicinity is the challenge because of the low voltage induced in that area. The 100% stator …
-
Transient based earth fault location in 110 kV subtransmission networks
This thesis deals with ground fault location in subtransmission networks. The main subject of the thesis is transient based ground fault location using low frequency fault generated transients. However, the thesis also considers the conventional fault location methods and reviews the various other …
-
Cogeneration in distribution system : planning, operation, transients
… of the induction generator, by single line-to-ground fault, double line-to-ground fault through contact resistances, broken conductor touching the ground through a small resistance, isolating the induction generator to form its own supply domain (islanding) etc are investigated and interesting …
-
Fault clearance in distributed power architectures with limited energy flow through power electronic interfaces
… to melt a fuse in the event of a line to ground fault. DC micro-grids rely on power electronic converters to change voltage levels. All converters rely on semiconductor switches that must be protected from surges of fault current. This limits the power that a converter can supply to a …
-
Modeling and Simulation of Transient Fault Response at Lillgrund Wind Farm when Subjected to Faults in the Connecting 130 kV Grid
… of this thesis was to investigate what type of faults in the connecting grid should be dimensioning for future wind farms. An investigation of over and under voltages at the main transformer and the turbines inside Lillgrund wind farm was the main goal. The results will be used in the planning …
-
Fault location on EHV lines using wideband spread spectrum techniques
Electrical authorities require fast and accurate fault locators to protect tha quality of supply and reduce outage times. Spread spectrum techniques perform well in high noise environments such as power lines and their use in radar ranging is well known. Existing power line carrier (PLC) equipment …
-
A study of some unbalanced fault conditions of power systems
… solutions to the problem of power systems fault and stability studies. However, with a few notable exceptions, previous efforts have largely been confined to attempts to solve the problems in the classical manner by having the computer simply take over the tedious portion of the …
-
Modeling of doubly-fed induction generators connected to distribution system based on eMEGASim® real-time digital simulator
… simulator, some studies such as three-phase to ground fault and voltage sag have been made to test the response of the model.
-
A study of the effects of full three-phase representation in power system analysis
… transient overvoltages caused by single line-to-ground fault clearing and, therefore, may be represented fully transposed. It is noted, on the other hand, that unbalanced loads can affect the transients and must be included in the analysis. It has been shown, however, that balanced initial …
-
SOLAR MICROINVERTER TOPLOGIES FOR PHOTOVOLTAIC GENERATION SYSTEMS
… topologies have high efficiency and easy ground fault current detection, but they lack the high voltage gain required. This thesis proposes a novel coupled inductor based two-stage non-isolated microinverter, which has high voltage gain and high efficiency. To compare the performance of …
Page 1 of 3