Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"ground loop"”.

  1. Modeling and Analysis of Ground Loop Cooling for Thermo-Electric Power Generation

    The focus of this thesis is to model a ground loop cooling system to substitute for typical cooling systems of a thermal power plant. Steam power plants generate heat from fuel (e.g., coal, natural gas, and nuclear) which is used to convert water to steam and which, in turn, expands through …

    ku Repository record for Modeling and Analysis of Ground Loop Cooling for Thermo-Electric Power Generation (opens in a new tab)

  2. The effects of soil heterogeneity on the performance of horizontal ground loop heat exchangers

    Horizontal ground loop heat exchangers (GLHE) are widely used in many countries around the world as a heat source/sink for building conditioning systems. In Canada, these systems are most common in residential buildings that do not have access to the natural gas grid or in commercial structures …

    waterloo Repository record for The effects of soil heterogeneity on the performance of horizontal ground loop heat exchangers (opens in a new tab)

  3. Simulation of a vertical ground-coupled heat pump system with optimal ground loop design

    … the thermal energy found in the earth's crust. Ground coupled heat pumps (GCHP) consist of a water-to-air or water-to-water heat pump, a circulator pump, a buried pipe grid and an interconnecting header. Heat is extracted from or rejected to the ground through this buried pipe grid that …

    wvu Repository record for Simulation of a vertical ground-coupled heat pump system with optimal ground loop design (opens in a new tab)

  4. Development of an integrated building load-ground source heat pump model as a test bed to assess short- and long-term heat pump and ground loop performance

    Ground source heat pumps (GSHP) have the ability to significantly reduce the energy required to heat and cool buildings. Historically, deployment of GSHP's in the cooling-dominated Texas and Southwest region has been significantly less than in other regions of the United States. The long term …

    texas Repository record for Development of an integrated building load-ground source heat pump model as a test bed to assess short- and long-term heat pump and ground loop performance (opens in a new tab)

  5. Development of an integrated building load and ground source heat pump model to assess heat pump and ground loop design and performance in a commercial office building

    Ground source heat pumps (GSHPs) offer an efficient method for cooling and heating buildings, reducing energy usage and operating cost. In hot, arid regions such as Texas and the southwest United States, building load imbalance towards cooling causes design and performance challenges to GSHP …

    texas Repository record for Development of an integrated building load and ground source heat pump model to assess heat pump and ground loop design and performance in a commercial office building (opens in a new tab)

  6. Numerical analysis of the long-term thermal performance of a solar assisted foundation heat exchanger - ground source heat pump system for space heating and cooling in extremely cold climates

    … to the high capital costs associated with the ground source heat pump systems, foundation heat exchangers offer a non-conventional solution by utilizing the building's foundation and the heat capacity of underground soil for efficient space heating and cooling. However, the performance of …

    calgary Repository record for Numerical analysis of the long-term thermal performance of a solar assisted foundation heat exchanger - ground source heat pump system for space heating and cooling in extremely cold climates (opens in a new tab)

  7. Dynamic Modeling and Control of a Hybrid Hydronic Heating System

    … natural gas fired boiler hot water heating and a ground source heat pump system. The overall system consists of several components such as a boiler, a heat exchanger, a ground loop heat pump, a ground loop heat exchanger, baseboard heaters, and radiant floor hydraulic piping systems. The system …

    concordia Download PDF for Dynamic Modeling and Control of a Hybrid Hydronic Heating System (opens in a new tab)

  8. The Impact of Parasitic DC And AC Sources on the Security of the KLJN Secure Key Exchange Scheme

    … on utilizing a parasitic voltage-source in the loop. Relevant situations often exist in the low-frequency limit in practical systems, especially when the communication is over a distance or between different units within an instrument, due to a ground loop and/or electromagnetic interference …

    tamu Repository record for The Impact of Parasitic DC And AC Sources on the Security of the KLJN Secure Key Exchange Scheme (opens in a new tab)

  9. Performance Evaluation of a Ground Source Heat Pump System in South Dakota: Winter of 1993-1994

    … basis. The analysis of run fraction verses loop length and heat transfer rates indicated that the steady-state run fraction value currently being used in the ground loop design equation should possibly be replaced with a run fraction factor which is a function of the run fraction.

    sdstate Repository record for Performance Evaluation of a Ground Source Heat Pump System in South Dakota: Winter of 1993-1994 (opens in a new tab)

  10. The performance of vertical ground source heat pumps (GSHPs) in hot dry climates Saudi Arabia as a case study

    … energy systems, such as those employing ground source heat pumps (GSHPs). The GSHP is cooling/heating system that transfer heat to or from the ground benefiting from the fact that the underground temperature remains almost constant all year-round at ten metres in depth or more. This means …

    whiterose Download PDF for The performance of vertical ground source heat pumps (GSHPs) in hot dry climates Saudi Arabia as a case study (opens in a new tab)

  11. Enhancing geothermal heat pump systems with parametric performance analyses

    … vapor compression cycles. Motor cooling reduces ground loop heat exchanger length with similar COP, and economizers allow for an increase in COP compared to the basic cycle.

    uoit Repository record for Enhancing geothermal heat pump systems with parametric performance analyses (opens in a new tab)

  12. Development of a Power Hardware-in-the-Loop Test Bench for Electric Machine and Drive Emulation

    … a power electronic based power hardware-inthe- loop (PHIL) platform to emulate electric machines for the purpose of a motor drive testbench with a particular focus on induction machine emulation. PHIL presents advantages over full-hardware testing of motor drives as the PHIL platform can save …

    vt Repository record for Development of a Power Hardware-in-the-Loop Test Bench for Electric Machine and Drive Emulation (opens in a new tab)

  13. The architectural impact of using ground-source heat pumps in commercial buildings in Las Vegas

    … on the design and long term performance of ground-coupled heat pump systems over a fixed period of time. The results are applied to a commercial office building in order to assess the net impact of combining various energy efficiency strategies. The conclusion of the comprehensive study is …

    unlv Repository record for The architectural impact of using ground-source heat pumps in commercial buildings in Las Vegas (opens in a new tab) Download PDF for The architectural impact of using ground-source heat pumps in commercial buildings in Las Vegas (opens in a new tab)

  14. High-efficiency Transformerless PV Inverter Circuits

    … (PWM) method for reactive power generation. The ground loop voltage of this inverter under the proposed PWM method is also derived with common mode and differential mode circuit analyses, which indicate that high-frequency voltage component can be minimized with symmetrical design of inductors. A …

    vt Repository record for High-efficiency Transformerless PV Inverter Circuits (opens in a new tab)

  15. Using System Data to Understand the Performance of Multi-Occupancy and Commercial Ground Source Heat Pumps in the UK

    … net zero by 2050, as legislated in the UK. Ground source heat pumps will be a key technology in realising this, though little data is available on their long-term performance in the UK, particularly commercial and multi-family systems. Extracting the learning from heat pumps currently in …

    whiterose Download PDF for Using System Data to Understand the Performance of Multi-Occupancy and Commercial Ground Source Heat Pumps in the UK (opens in a new tab)

  16. Heat transfer computational methods which can also be applied to geothermal field of study for energy saving and environmental benefits

    The current work is focused on the Ground Source Heat Pump Systems (GSHPSs) coupled to closed vertical ground loop. Several factors that affect the system’s performance are examined. Two different approaches are developed. In the first one, an overall view of system’s performance is studied using …

    greece Repository record for Heat transfer computational methods which can also be applied to geothermal field of study for energy saving and environmental benefits (opens in a new tab)

  17. Supplemental heat rejection in ground source heat pumps for residential houses in Texas and other semi-arid regions

    Ground source heat pumps (GSHP) are efficient alternatives to air source heat pumps to provide heating and cooling for conditioned buildings. GSHPs are widely deployed in the midwest and eastern regions of the United States but less so in Texas and the southwest regions whose climates are described …

    texas Repository record for Supplemental heat rejection in ground source heat pumps for residential houses in Texas and other semi-arid regions (opens in a new tab)

  18. Advanced electromagnetic methods for deep mineral exploration : development of a three-component transmitter system and principal component analysis for target discrimination

    … three orthogonal, co-located transmitter loops operating simultaneously at distinct base frequencies (30, 32.5, and 35 Hz). The system was validated through three field tests, demonstrating that individual transmitter signals can be successfully separated during processing with minimal …

    laurentian Repository record for Advanced electromagnetic methods for deep mineral exploration : development of a three-component transmitter system and principal component analysis for target discrimination (opens in a new tab)

  19. Multi-year Operation Effect of Geothermal Heat Exchanger on Soil Temperature for Unt Zero Energy Lab

    Ground source heat pump (GSHP) uses earth’s heat to heat or cool space. Absorbing heat from earth or rejecting heat to the earth, changes soil’s constant temperature over the multiple years. In this report we have studied about Soil temperature change over multiple years due to Ground loop heat …

    unt Repository record for Multi-year Operation Effect of Geothermal Heat Exchanger on Soil Temperature for Unt Zero Energy Lab (opens in a new tab)

  20. Design of a Low-Cost Data Acquisition System for Rotordynamic Data Collection

    A data acquisition system (DAQ) was designed based on the use of a STM32 microcontroller. Its purpose is to provide a transparent and low-cost alternative to commercially available DAQs, providing educators a means to teach students about the process through which data are collected as well as the …

    calpoly Repository record for Design of a Low-Cost Data Acquisition System for Rotordynamic Data Collection (opens in a new tab)