Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 91 for “"guidewire"”
-
Enhancing Guidewire Coupling in Balloon Catheters
… is the mechanical coupling of a percutaneous guidewire (PGW) with an internal balloon catheter (IBC). Despite thousands of successful implementations, inconsistencies from the internal decoupling of the PGW and IBC necessitate improvements, particularly to accommodate obese patients. A …
-
Development of a New Guidewire Torque Device
Guidewires have been used in many operating rooms by vascular surgeons to assist them in positioning and maneuvering through a tortuous stenosis or lesion to a desired location, and to be used as a guide for the implantation of a catheter. Surgeons are tasked with having to insert a guidewire …
-
Array design and development for steerable robotic guidewire
… when CTOs are present. A steerable robotic guidewire with integrated forward-viewing imaging capabilities would allow the guidewire to navigate through tortuous vasculature and facilitate crossing CTOs in revascularization procedures that currently fail due to inability to route the …
-
Diagnostic Reliability of Guidewire in Evaluation of Coronary Artery Stenoses
… is to evaluate the diagnostic reliability of guidewires in analyzing the severity of coronary stenoses (blockages) through combined flow and pressure measurements. It is hypothesized that presence of a guidewire will produce an obstructive effect and, thus an additional “artifactual blockage”. …
-
Autonomous catheter and guidewire navigation for robotic percutaneous coronary interventions
Cette thèse porte sur la navigation automatique de guides et cathéters dans les artères coronaires. Dans un premier temps, nous introduisons le contexte de la cardiologie interventionnelle et le cas particulier des interventions coronaires percutanées. Nous justifions aussi l'utilité de la …
-
Development of a shape-memory-alloy-based smart guidewire for biomedical applications.
… overall patient outcomes. However, current guidewire technology has limited internal navigability relying on external manipulation of the wire to reposition the guidewire internally. Shape memory alloys (SMAs) are a group of materials that have the unique ability to recover trained shapes …
-
Forward-Viewing Ultrasound Guidance of a Robotically-Steered Guidewire for Peripheral Interventions
… The transducer was integrated with a robotic guidewire, and an image formation strategy was developed with synthetic aperture beamforming from the expanded aperture formed while steering the guidewire. The developed system provides a highly functional, sub-mm guidewire that can directly …
-
A Micro-Guidewire for Thrombus Identification and Classification Based on Electrical Impedance Properties
… To address this issue, we developed a micro-guidewire-based classification system, constructing a comprehensive research chain encompassing sensor design, mechanism exploration, algorithm development, and noise-resistant optimization. Using precision lithography-sputtering-laser processing …
-
Catheter Localization Utilizing a Sensor-Enabled Guidewire: Design of a Proof-of-Concept System
… sensor by utilizing a sensor enabled guidewire. The motivation for the project was a reduction fluoroscopy radiation dose for clinicians in the interventional cardiology lab and the extension of navigation technology to be used with a wider variety of interventional devices through the …
-
Mitigation of intrarenal pressure in retrograde intrarenal surgery with a novel isoprenaline eluting guidewire
… efficacy of an innovative isoprenaline-eluting guidewire (IsoWire), a platform guidewire intended for the administration of topical isoprenaline, a beta-receptor agonist, to the genitourinary system. This is the first study to report the delivery of isoprenaline using a drug-eluting guidewire. …
-
Guidewire Flow Obstruction Effect on Diagnosis of Coronary Lesion Severity: In-Vitro Experimental and Numerical Study
… flow are measured by inserting a sensor tipped guidewire of diameter 0.014" across the stenosis. The guidewire insertion across the coronary stenosis alters the transstenotic hemodynamics by producing “artifactual blockage” which causes reduction in pharmacologically induced hyperemic flow and …
-
Design and Analysis of a Compact Mechanism for the Motion of Tendon-Driven Steerable Robotic Guidewires
This thesis presents a novel compact guidewire advancement mechanism for micro- scale tendon-driven steerable robotic guidewires. Robotic guidewires allow surgeons to possess greater dexterity in minimally invasive surgeries in order to navigate to areas not attainable through conventional open …
-
Preventing Retained Central Venous Catheter Guidewires
Whole central venous catheter (CVC) guidewire retention is an iatrogenic error, with an incidence of 1:3,167, a morbidity of 4-53%, mortality of 4-6% and is a never event. Since 2011, health policy has mandated that all hospitals must implement national safety guidance to prevent this error, …
-
Improved Diagnostics of Coronary Stenoses with Lesion Flow Coefficient Using Guidewires
… decades. With the advent of small diameter guidewire, newer diagnostic endpoints were introduced. Among them, coronary flow reserve (CFR) and myocardial fractional flow reserve (FFRmyo) were most widely accepted. However, CFR was affected by several parameters such as the presence of …
-
Multizentrische, randomisierte Vergleichsstudie von zwei „High performance“ Führungsdrähten für die Endoskopisch-retrograde Cholangiopankreatographie (ERCP)
During interventional procedures in ERCP, guidewires are always used. These come in different designs, but it is not yet clear which type of guidewire offers the best success rates for different indications. The aim of this study is to evaluate and compare various modern ERCP guidewires (angled vs. …
-
Design, Modeling, and Image-Based Control of Robotically Steerable Systems for Endovascular Interventions
… interventions by skilled clinicians using guidewires, typically navigated through tortuous vasculature under fluoroscopic imaging. However, challenges such as limited steerability and complex anatomy demand innovative solutions. This research presents the design, modeling, and control of …
-
Design, Modeling, and Image-Based Control of Robotically Steerable Systems for Endovascular Interventions
… interventions by skilled clinicians using guidewires, typically navigated through tortuous vasculature under fluoroscopic imaging. However, challenges such as limited steerability and complex anatomy demand innovative solutions. This research presents the design, modeling, and control of …
Page 1 of 5