Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"halogen lamp"”.

  1. Measurements of optical properties of bulk and thin film semiconductors using the PDS technique

    … with a f/3.8 monochromator and a 150W Tungsten Halogen lamp, a HeNe laser for the probe beam, CCI[superscript omitted] for the deflecting medium and a linear position sensitive detector. The spectra obtained for GaAs and GaNAs were compared with models based on the Rosencwaig-Gersho and the …

    ubc Repository record for Measurements of optical properties of bulk and thin film semiconductors using the PDS technique (opens in a new tab) Download PDF for Measurements of optical properties of bulk and thin film semiconductors using the PDS technique (opens in a new tab)

  2. Green photochemistry: solar synthesis of fine chemicals, development of novel porphyrin nano structured solid supported sensitizers and implementation of a novel photochemical microflow reactor.

    … alcohols under both artificial light (500 W halogen lamp) and natural light (sunlight) conditions. The reactions were assessed for greenness using the twelve principles of green chemistry and several key factors were identified as having a significant negative impact on this greenness. These …

    dcu Download PDF for Green photochemistry: solar synthesis of fine chemicals, development of novel porphyrin nano structured solid supported sensitizers and implementation of a novel photochemical microflow reactor. (opens in a new tab)

  3. Quantum Dot Deposition Into PDMS and Application Onto a Solar Cell

    … under identical illumination by a tungsten halogen lamp, using QDs that fluoresce in the orange region. This work demonstrates the feasibility of incorporating QDs to increase the efficiency of conventional solar cells. Because the solar cells absorb better in the red region, future effort …

    calpoly Repository record for Quantum Dot Deposition Into PDMS and Application Onto a Solar Cell (opens in a new tab)

  4. Implementation of Infrared Non-Destructive Evaluation in Fiber-Reinforced Polymer Bouble-Web I-Beams

    … conduction in these beams. This project used a halogen lamp to heat the surface of the beam followed by an observation with an IR camera. Calculations of an ANSYS finite element analysis (FEA) model were compared with a series of laboratory tests. The experimental results allowed for validation …

    vt Repository record for Implementation of Infrared Non-Destructive Evaluation in Fiber-Reinforced Polymer Bouble-Web I-Beams (opens in a new tab)

  5. Kietakūnio konversijos fosfore šviesos šaltinio psichofizikinis vertinimas /

    … this lighting is different from the lighting of halogen lamps, which is defined as a warm white color. Also, to compare how much PrefLED lighting seems more pronounced and brighter compared to halogen lighting. Psychophysical experiments are carried out in a parallel, mirrored manner to …

    vilnius Repository record for Kietakūnio konversijos fosfore šviesos šaltinio psichofizikinis vertinimas / (opens in a new tab)

  6. Design of a fiber optic oxygen sensor based on immobilized hemoglobin

    … oxygen free sample cell. Light from a tungsten-halogen lamp, filtered through a 405nm filter is passed through one arm of a bifurcated fiber to the sample cell. The reflected intensity (a highly polished aluminum foil or a plate is placed at the bottom of the sample cell ) from the other arm of …

    njit Repository record for Design of a fiber optic oxygen sensor based on immobilized hemoglobin (opens in a new tab)

  7. Photorejuvenation Induced by 5-Aminolevulinic Acid Photodynamic Therapy in the Patients with Actinic Keratosis: A Histological Analysis

    … treated twice with ALA-PDT using a 1200W metal halogen lamp at one month intervals. Skin biopsy before and one month after the PDT was performed. Twenty five pairs of specimens were obtained. I examined the specimens with routine and immunohistochemical staining and evaluated the parameters …

    ajou Repository record for Photorejuvenation Induced by 5-Aminolevulinic Acid Photodynamic Therapy in the Patients with Actinic Keratosis: A Histological Analysis (opens in a new tab) Embargoed until 9999-12-31

  8. Design and fabrication of a piezoelectric micro dispensing printing system

    … oven sintering, and (ii) A 500 W 120 V tungsten halogen lamp sintering. The sintering results were compared using these methods. Oven sintering process was done at different temperatures and time. Incandescent lamp sintering was done varying the distance of the printed structures from the lamp …

    manitoba Repository record for Design and fabrication of a piezoelectric micro dispensing printing system (opens in a new tab)

  9. Reliability of Liquid Core Optical Waveguides for Sensitive Optical Absorption Measurements of Trace Species in water

    … used conventional light sources such as Xenon or Halogen lamps and not spectroscopic laser sources. In this thesis study, we used a LWCC absorption waveguide and a laser light source to measure, for the first time to our knowledge, the optical transmission through several water or liquid samples. …

    usf Repository record for Reliability of Liquid Core Optical Waveguides for Sensitive Optical Absorption Measurements of Trace Species in water (opens in a new tab)

  10. Nondestructive evaluation of FRP composite bridge componenets using infrared thermography and digital tap tesing

    … also includes IRT based tests using a low-cost halogen lamp heater, which is compared to the heating capability of VoyageIR Pro (advanced IRT equipment). Also, Digital Tap Hammer was used for rapid evaluation of the defects in the structural members, which provides a scientific alternative to …

    wvu Repository record for Nondestructive evaluation of FRP composite bridge componenets using infrared thermography and digital tap tesing (opens in a new tab)

  11. A microprocessor based multiwavelength-detector system for liquid chromatography

    … the intensity of the light source, a 55 W quartz-halogen lamp, the slit size used in the spectrometer and the sweep frequency, 500 or 50 KHz. To test the utility of the detector, the reduction of nitrobenzene to azoxybenzene and azobenzene was monitored with the standard single wavelength (254 …

    vt Repository record for A microprocessor based multiwavelength-detector system for liquid chromatography (opens in a new tab)

  12. Photothermal Desorption of Toluene from Single Walled Carbon Nanotube and Activated Carbon Sorbents

    … desorbed by irradiation with a common 50W halogen lamp. When irradiated at the highest lamp setting for four minutes, AC and SWNT-p samples desorbed 45.9% (+/-5.39) and 70.5% (+/- 5.67) respectively. Both materials met method validation criteria of 95% confidence interval within 25% of true …

    uab Repository record for Photothermal Desorption of Toluene from Single Walled Carbon Nanotube and Activated Carbon Sorbents (opens in a new tab)

  13. Modeling and Characterization of Polycrystalline Mercuric Iodide Radiation Detectors

    … documented in this thesis, a tungsten-halogen lamp and an Oriel 1/4m grating monochromator are used as a light source. The incident flux on the sample is determined using a Si photodiode as reference. Device performance for both single crystal as well as polycrystalline films is …

    usf Repository record for Modeling and Characterization of Polycrystalline Mercuric Iodide Radiation Detectors (opens in a new tab)

  14. New Tools for Real-Time Study of Embryonic Development

    … can be illuminated under a standard microscope halogen lamp and characterized simultaneously using DFOMS equipped with a multi-spectral imaging system to achieve real-time multiplexing imaging. Our studies show that Au NPs are much more biocompatible than Ag NPs, while Ag NPs are much more …

    odu Repository record for New Tools for Real-Time Study of Embryonic Development (opens in a new tab)

  15. Near-infrared spectral imaging as a detection technique for organic materials in porous media

    … transmittance using a 250 W quartz-tungsten-halogen lamp for sample illumination. The first series of investigations focused on the analysis of laboratory-scale flow cells, which are used to study the transport of non-aqueous phase liquid (NAPL) contaminants in the soil and groundwater. …

    arizona-thes Repository record for Near-infrared spectral imaging as a detection technique for organic materials in porous media (opens in a new tab)

  16. PHASE-SPACE PERSPECTIVE OF PARTIALLY COHERENT IMAGING: APPLICATIONS TO BIOLOGICAL PHASE MICROSCOPY

    … or from a range of directions (e.g. using a halogen lamp with high-NA condenser, as in conventional microscopy). Methods that illuminate from a range of directions using an incoherent source (and hence give rise to partially coherent field at the specimen) provide high transverse and axial …

    nus Repository record for PHASE-SPACE PERSPECTIVE OF PARTIALLY COHERENT IMAGING: APPLICATIONS TO BIOLOGICAL PHASE MICROSCOPY (opens in a new tab) Download file for PHASE-SPACE PERSPECTIVE OF PARTIALLY COHERENT IMAGING: APPLICATIONS TO BIOLOGICAL PHASE MICROSCOPY (opens in a new tab)

  17. Advanced Luminescence-Based Characterization Techniques For Perovskite Solar Cells

    … implied open-circuit voltage. We calibrate the halogen lamp with known absolute intensity to accurately calculate the scaling factor (SF) accounting for the detected light fraction. Our approach is validated through various independent techniques, including lifetime-calibrated PL, spectrally …

    anu Repository record for Advanced Luminescence-Based Characterization Techniques For Perovskite Solar Cells (opens in a new tab)

  18. An investigation into the effects of light intensity on nitrate and nitrite excretion and uptake by Chaetoceros curvisetus (STX-200)

    … were generated with a 1000-watt tungsten-halogen lamp in combination with copper sulfate and heat filters. The cultures were spiked with nitrate and the nitrate and nitrite concentrations were monitored simultaneously and continuously with a Technicon Autoanalyzer II interfaced with a …

    texas Repository record for An investigation into the effects of light intensity on nitrate and nitrite excretion and uptake by Chaetoceros curvisetus (STX-200) (opens in a new tab)

  19. The non-invasive quantification of cutaneous haemoglobin and its oxygenation by reflectance spectrophotometry

    … instrument the radiation from a 6V, 20 W quartz halogen lamp is transmitted to the reflectance probe by fibre optics and illuminates the skin surface perpendicularly. The diffuse reflected light is then collected and transmitted to a rotating circular variable filter, CVF. The CVF is driven by a …

    whiterose Download PDF for The non-invasive quantification of cutaneous haemoglobin and its oxygenation by reflectance spectrophotometry (opens in a new tab)

Page 1 of 2