Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 40 for “"hand tool"”.
-
Method for the Evaluation of an Ergonomic Hand Tool
… has lead to an influx of 'ergonomically correct' tools into industry. When considering the purchase of these tools, Purchasing and Engineering personnel are forced to rely on subjective evaluation as the basis of their procurement decision. This study establishes quantitative parameters to aid in …
-
Analyzing power driven hand tool operation using low-cost sensors
Equipping power hand tools with low-cost, machine-learning-enabled sensors can provide valuable insight and real-time analytics about safe and efficient tool usage. As a first step towards this end, this thesis presents a prototype for a “smart” tool module (STM) that can estimate the force being …
-
Optimizing a Hammer Forging Progression for a Large Hand Tool
… the forging process of one of their large hand tool products. A large wrench, forged at GBDF was noticed to contain a large amount of flash and excessive amount of hammer blows required to forge the part. The large amounts of flash and excessive hammer blows increased forging time and money …
-
Study of the loading of the hand during hand tool operation
Measurement and prediction of the loading of the hand is important for developing functional biomechanical models and for designing ergonomical tools, work equipment and manual handling activities. The loading of the hand was investigated in this study by focussing on the following objectives: (1) …
-
Lumped Parameter Modeling and Parameter Investigation of An Electrohydraulic Crimping Hand Tool
A lumped parameter model of a hand-held electrohydraulic tool was developed. The tool modeled was a Milwaukee Tool M18 12 Ton Crimper. First principle approaches were used to develop state-space models for each of the subsystems in the tool. The included subsystems were the tool motor and gear …
-
Ergonomic evaluation of shoulder muscle activation during light weight hand tool exertion task
… the effect of shoulder muscle activation during hand exertion tasks using a light weight hand tool by working individuals. Electromyography (EMG) of trapezius, supraspinatus, triceps, and pectoralis major was conducted for 45 , 0 and -45 arm angles, for three different reaches i.e. normal, …
-
A Comprehensive Methodology for Assessing Biomechanical Risks Associated with Hand Tool Use: Applied to Laparoscopic Surgical Instruments
… risk factors associated with surgical hand tools had never been performed. Utilizing an opto-electronic motion capture system meant the exact surgeon posture was recorded during simulated surgical tasks. Electromyography was used to evaluate muscle recruitment and workload for small …
-
Comprehensive hand and power tool evaluation for comprehensive knowledge & expected returns (C.H.E.C.K.E.R.): a novel method for maximizing returns in industrial tool selection
… begins with an investigation into how hand tool purchasing decisions are made in the enterprise environment and how hand tool purchasing and evaluation are conducted from an academic perspective. A hand tool, as a type of equipment used by people to create products and complete …
-
The effect of handle characteristics of a hammer stapler on biomechanical and physiological response
… and prolonged use of an improperly designed hand tool not only affects productivity but may also cause painful symptoms which, if left untreated, can develop into chronic musculoskeletal disorders (MSDs). This study was undertaken to assess the effects of ergonomic guidelines related to grip …
-
ROBOT-ASSISTED PROBE POSITIONING FOR INTRAOPERATIVE ULTRASOUND IMAGING USING FORCE CONTROL AND REINFORCEMENT LEARNING
… positioning based on ultrasound image inputs. Hand-tool calibration enables the correct synchronization of the robotic end-effector with the probe. For motion planning, a deep reinforcement learning model was trained on ultrasound images synthesized from CT scans to automate probe positioning, …
-
Isometric forces transmitted by the digits: data collection using a standardized protocol
… would prove particularly useful in areas such as hand-tool and control design, and also in medical evaluation. A standardized protocol is necessary if a sound, useful data base is to be built. This study developed such a protocol and data were collected using the defined protocol. The study also …
-
Vibration Analysis of a Hand-Held Percussion Tool Coupled with the Hand-Arm System
Exposure to hand-transmitted vibration (HTV) arising from hand power tools has long been associated with several disorders of the hand and arm, which are collectively termed as hand-arm vibration syndrome (HAVS). Owing to high prevalence of HAVS among the operators of the power tools, particularly …
-
An Evaluation of Fatigue and Performance Changes During Intermittent Overhead Work
… levels of duty cycles, two work heights, and two hand positions). Four dependent measures based on endurance, subjective, objective, and physiological fatigue were used to quantify shoulder fatigue and were collected during the experiment. An overhead work task required participants to use a hand …
-
Assessing Organizational Effectiveness Through the Competing Values Framework A Data Envelopment Approach
… topic by using data envelopment analysis as a tool to measure relative efficiency based on a predefined effectiveness model. The effectiveness model is prepared on basis of competing values framework. The relative efficiency scores that are obtained though this integrated approach compare and …
-
Perception of safety and usability of powered hand tools
… was to identify the relationship between powered hand tool design features and risk and usability perception. The general goal of this research was to provide information that will help in the design of tools that do not create inaccurate impressions of safety or usability.;Safety and usability …
-
An ergonomic evaluation of Speed Fastening work rates
… for SF is the development of a continuously feed tool that would eliminate the non-value added time currently scheduled for reloading in the work cycle. In preparation for the design of a new tool, a proactive ergonomic investigation was carried out to examine differences in muscular effort, …
-
Design mechanické sponkovačky
Tématem mé bakalářské práce je design mechanické sponkovačky. Produkt je nejdříve analyzován z designerské, marketingové a technické stránky. Na základě analýz je navržen nový design, který splňuje ergonomické, technické a psychologické aspekty. Dalšími nároky jsou jednoduché, snadno ovladatelné …
-
Assessments of Vibratory Handheld Tools and Handle Interactions
… of injuries occurring as the result of vibratory hand-tool use. Following these findings, three human safety standards have been proposed. These standards declare that the dynamic properties with respect to acceleration frequency spectra must be determined for vibratory hand tools. These …
-
Multifractality as a lens on embodied human computer interaction
… are informative about dimensions of ready-to-hand tool use — an influential construct in Embodied Interaction, drawn from phenomenological philosophy, which describes fluid, engaged tool use, in which the tool "disappears" for the user.<br/><br/>I also investigate the potential to apply …
-
Analysis of an Anti-vibration Glove for Vibration Suppression of a Steering Wheel
Exposure to severe levels of hand-arm vibration can lead to hand-arm vibration syndrome. Towards curbing the development of hand-arm vibration syndrome, studies have shown that anti-vibration gloves effectively reduce the transmission of unwanted vibration from vibrating equipment to the human …
Page 1 of 2