Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 119 for “"handling unit"”.
-
Company Air Handling Unit Online Management System /
Currently company air handling units are used for ventilation of buildings and they can only be controlled in local area network (LAN). This does not allow the company customers to control the microclimate of their home in a convenient way (e.g. when they are away from home). Therefore, there is a …
-
Process monitoring and fault classification for an air handling unit
… methods to identify system faults in an air-handling unit (AHU). The effects of using a reduced amount of available information are investigated. The faults are simulated and are applied in an actual flow loop facility;The process model fault scheme as presented in Iserman (1987) was adopted …
-
Energy Optimization of Air Handling Unit Using CO₂ Data and Coil Performance
Air handling unit systems are the series of mechanical systems that regulate and circulate the air through the ducts inside the buildings. In a commercial setting, air handling units accounted for more than 50% of the total energy cost of the building in 2013. To make the system more energy …
-
Modeling and Analysis of an Air Handling Unit to Improve Energy Efficiency
The Air Handling Unit (AHU), which serves the entire basement of Engineering and Technology (ET) building on IUPUI campus, had constant set points of discharge air temperature and supply air static pressure. Two reset schedules were investigated to determine which was the best control strategy to …
-
Development of an integrated laboratory air handling unit (LAHU) system for laboratory buildings
… and implementation of an integrated air handling unit system for laboratory buildings, called the Laboratory Air Handling Unit (LAHU) system. This system minimizes thermal energy use and improves the office area indoor air quality (IAQ) in laboratory buildings. Theoretical optimal airflow …
-
Evaluation of Performance of an Air Handling Unit Using Wireless Monitoring System and Modeling
… controlled as expected. In this thesis, an air handling unit (AHU) of an HVAC system was modeled to analyze its performance using real data collected from an operating AHU using a wireless monitoring system. The purpose was to monitor the AHU's performance, analyze its key parameters to identify …
-
The use of fault detection and diagnostics to reduce air handling unit energy consumption
… Conditioning (HVAC), and more specifically Air Handling Units (AHUs) energy consumption accounts on average for 40% of a typical medical device manufacturing or pharmaceutical facility’s energy consumption. Studies have indicated that 20 – 30% energy savings are achievable by recommissioning …
-
Fault Detection and Diagnostics in Single-Duct Multiple-Zone Variable Air Volume Air Handling Unit Systems
Variable air volume (VAV) air handling unit (AHU) systems are the most common heating, ventilation, and air conditioning (HVAC) configuration in North America's commercial buildings. They account for a large fraction of sensors and actuators and are prone to faults due to their control systems' …
-
A Profile of Inmates Admitted to the Special Handling Unit in the Correctional Service of Canada
The Special Handling Unit (SHU) is a prison facility that provides increased supervision and restrictions for inmates who cannot be appropriately managed at a maximum-security institution. SHU confinement differs from other types of segregation (e.g., administrative) in criteria for admission and …
-
A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique
<p>A plug and play framework for an HVAC air handling unit control system is proposed in this study. This is the foundation and the first step towards the plug and play HVAC control system that will eventually lead to self-configuring of HVAC control systems for automatic building controls system …
-
DEVELOPMENT AND EVALUATION OF NOVEL AIR HANDLING UNIT CONTROL STRATEGIES FOR IMPROVED BUILDING DEMAND FLEXIBILITY AND THERMAL COMFORT
… power demand, up to 80% in some regions in the United States. With many flexible loads, buildings have the potential to reduce power demand during peak times and provide demand flexibility. Building enables demand flexibility through measures such as shifting energy use to another time and …
-
Simulation on centrifugal fans operating at close distance: An investigation of different air handling unit constructions to improve fan efficiency
… Finding an high energy efficient ventilation unit solution is of big interest for Swegon, the company which initiated this thesis, as it copes with current EU regulations and directives for environmental issues, and at the same time lowers the operating costs. The goal with this study is to …
-
Investigation of the Effect of Multiple Centrifugal Fans Close to Each Other in Operation- A Numerical Study to Improve Fan Efficiency in an Air Handling Unit
… flow medium. In manufacturing of compact Air Handling Units (AHU) where lower areal footprints are a necessity, several centrifugal fans (in parallel) are often use for each flow direction. It has been shown that there is a risk of decreased individual fan efficiency when multiple fans are …
-
Specialios paskirties patalpos vėdinimo įrenginio valdiklio teorinių parametrų skaičiavimas, programavimas ir testavimas /
Special-purpose Room Controller of Air Handling Unit Theoretical Parameters, Programming and Testing.
-
Calibration of a Building Energy Model Using Measured Data for a Research Center
… presents the calibration at the zone and air handling unit level. First a literature review is presented, followed by the evidence-based bottom-up methodology. Next, the case study building is described, along with the extraction and analysis of the monitored data. Then the building model is …
-
Modelvorming van een geavanceerd HVAC systeem van een museum depot: een simulatiemodel opgebouwd uit modulaire componenten om de systeemprestatie van een museumdepot te simuleren in geval van storing in de HVAC installatie
… indoor climate when a major failure in de air handling unit occurs. There will also be researched if it is recommended to treat the air of the cavity zone in case of a mayor failure. The Dutch Naval Depot gives housing to one of Dutch most valuable collections of artefacts, there cannot be …
-
Pumparbete samt returtemperatur för tre alternativa lösningar vid koppling till luftvärmare
… electric energy. There are pumps and fans in air-handling units. The task of the air handling unit is to provide the desired thermal indoor climate according to the demand of the users of the building. Buildings need heating or cooling in order to achieve the thermal comfort level. To do this we …
-
Advanced Thermodynamic Analyses of Energy Intensive Building Mechanical Systems
… (RCX) an existing building air handling unit (AHU), as well as conducting an advanced analysis on an existing chiller. The following research demonstrates the benefits of including a second law analysis in order to improve equipment operation based on lowered energy consumption …
Page 1 of 6