Results 1 to 20 of 84 for “"headform"”

  1. Simulating the Interaction between Head Protective Equipment and a Headform

    … to simulate the interaction between HPE and a headform. Two types of HPE are studied which are respirators and helmets. Three-dimensional digital headform, respirator and helmet are obtained using reverse engineering techniques. The commercial software, LS-DYNA, is used to model and simulate …

    ttu Repository record for Simulating the Interaction between Head Protective Equipment and a Headform (opens in a new tab)

  2. Pendulum Based Impact Testing of Athletic Helmets Using the NOCSAE Headform

    … during head impact tests using a NOCSAE headform. This additional data will allow researchers to more accurately characterize the effects of head impacts from sports related objects. This will not only serve to better characterize the effectiveness of currently available protective …

    unlv Repository record for Pendulum Based Impact Testing of Athletic Helmets Using the NOCSAE Headform (opens in a new tab)

  3. The Effect of Neck Stiffness on Headform Response and Intracranial Strain

    … to active states of musculature. A helmeted headform was attached to the neckform and subjected to frontal impacts, with X-ray imaging used to observe the brain surrogate. Although neck stiffness had limited effects on peak accelerations, the neck affected the headform's deceleration and …

    carleton Repository record for The Effect of Neck Stiffness on Headform Response and Intracranial Strain (opens in a new tab)

  4. The influence of test conditions on the results of pedestrian headform impact tests.

    Pedestrian headform impact tests are used to assess the relative level of danger that a vehicle poses to the head of a struck pedestrian. The tests are conducted using a dummy headform that is launched at specific locations on the front of a stationary vehicle. The conditions of the test are …

    adelaide Repository record for The influence of test conditions on the results of pedestrian headform impact tests. (opens in a new tab)

  5. Alternative injury response functions for evaluating head accelerations, with application to pedestrian headform testing.

    Impact testing of vehicles and helmets is performed under the specifications of a test protocol to ensure that regulatory standards and community expectations are met in terms of head injury safety. Impact severity is usually measured using the acceleration of the impactor (or dummy head) that is …

    adelaide Repository record for Alternative injury response functions for evaluating head accelerations, with application to pedestrian headform testing. (opens in a new tab)

  6. Design of a Free Motion Headform Impactor Support Structure for School Bus and Motor Coach Testing

    … conducted using the support structure. A 3.5 kg headform was fired using the impactor fixed to the support structure. Strain gauges were attached to the structure at the high stress concentration regions and the strain readings were recorded. Experimental results were compared with the simulation …

    ohiolink Repository record for Design of a Free Motion Headform Impactor Support Structure for School Bus and Motor Coach Testing (opens in a new tab)

  7. The Effect of Inbound Mass on the Dynamic Response of the Hybrid III Headform and Brain Tissue Deformation

    The varied impact parameters that characterize an impact to the head have shown to influence the resulting type and severity of outcome injury, both in terms of the dynamic response, and the corresponding deformation of neural tissue. Therefore, when determining head injury risks through event …

    ottawa-retro Repository record for The Effect of Inbound Mass on the Dynamic Response of the Hybrid III Headform and Brain Tissue Deformation (opens in a new tab)

  8. The Development and Validation of a Biofidelic Synthetic Eye for the Facial and Ocular CountermeasUre Safety (FOCUS) Headform

    … Current anthropometric test device (ATD) headforms lack instrumentation and facial features to allow detailed assessment of eye or discrete facial injuries. Therefore, the purpose of this dissertation is to present the development and validation of the Facial and Ocular CountermeasUre …

    vt Repository record for The Development and Validation of a Biofidelic Synthetic Eye for the Facial and Ocular CountermeasUre Safety (FOCUS) Headform (opens in a new tab)

  9. An Analysis of Head Impact angle on the Dynamic Response of a Hybrid III Headform and Brain Tissue Deformation

    … to better understand how impact angle influences headform dynamic response and brain tissue deformation. A bare headform was impacted using a pneumatic linear impactor at 5.5 m/s. The impacts were directed on the front and side location at angles of 0, 5, 10 and 15° rightward rotations as well as …

    ottawa-retro Repository record for An Analysis of Head Impact angle on the Dynamic Response of a Hybrid III Headform and Brain Tissue Deformation (opens in a new tab)

  10. A Laboratory Study on the Kinematic and Pressure Responses of an Internally Pressurized Novel Surrogate Headform Subjected to Blunt Impacts

    … the role of CSF within an artificial surrogate headform. To better grasp the role of CSF, particularly its positive pressure, this thesis explored how changing the internal resting pressure in a novel surrogate headform (BIPED) affects its kinematic and pressure responses to blunt impacts. …

    alberta Repository record for A Laboratory Study on the Kinematic and Pressure Responses of an Internally Pressurized Novel Surrogate Headform Subjected to Blunt Impacts (opens in a new tab)

  11. Biomechanical Assessment of Cycling Helmets: the Influence of Headform and Impact Velocity based on Cycling Collisions associated with Injury Claims

    … The second study compared peak dynamic headform responses between three headforms (two biofidelic and the magnesium headform currently used in testing standards) and also assessed the mitigating capacity of three brands of cycling helmets when subjected to impact velocities of standard …

    waterloo Repository record for Biomechanical Assessment of Cycling Helmets: the Influence of Headform and Impact Velocity based on Cycling Collisions associated with Injury Claims (opens in a new tab)

  12. New NIOSH Headforms: Developing Novel Methods for Fabricating a More Realistic Physical Headform and Custom Facepieces and Evaluating Existing Commercially-Available Respirators

    … was created in 2007. Anthropometrically accurate headforms three-dimensional models for the average face in each size were designed in 2010. While these headforms are intended for use in respirator design, it has yet to be determined whether a shift to five sizes of facepieces would improve fit …

    uab Repository record for New NIOSH Headforms: Developing Novel Methods for Fabricating a More Realistic Physical Headform and Custom Facepieces and Evaluating Existing Commercially-Available Respirators (opens in a new tab)

  13. Study of Barrier Face Coverings and Respirator Exhalation Filtration Efficiency and Exhaled Air Velocity During Wear

    … velocity. To achieve this, the study utilized headform testing systems to measure TOL and airflow velocity. Specifically, a hard surface headform was used for NIOSH Approved respirators and surgical masks, while two soft surface headforms of different sizes were used for the BFCs used by the …

    wvu Repository record for Study of Barrier Face Coverings and Respirator Exhalation Filtration Efficiency and Exhaled Air Velocity During Wear (opens in a new tab)

  14. Development and Implementation of Laboratory Test Methods for the Evaluation of Wearable Head Impact Sensors

    … A custom pendulum was used to impact a NOCSAE headform mounted on a Hybrid III neck. Sensors were tested under helmeted and unhelmeted conditions, according to their prescribed use. The headform was impacted at four locations, each at four impact energies ranging from 25 g to 100 g. Peak and …

    vt Repository record for Development and Implementation of Laboratory Test Methods for the Evaluation of Wearable Head Impact Sensors (opens in a new tab)

  15. Biomechanical Analysis of Equipment Modifications to Reduce Concussion Risk due to Projectile Impacts in Women's Lacrosse

    … with standard balls on headgear and bare headform conditions), (2) ball effects (impacts with lightweight and standard balls on a bare headform), and (3) combined effects (impacts with a lightweight ball on headgear against standard ball, bare headform impacts). Both interventions, …

    vt Repository record for Biomechanical Analysis of Equipment Modifications to Reduce Concussion Risk due to Projectile Impacts in Women's Lacrosse (opens in a new tab)

  16. Experimental Evaluation and Comparison of Football-Related Head Impacts Among Ovine, Human, and Hybrid III Headforms

    … rely heavily on the Hybrid III surrogate headform to evaluate protective performance, these surrogate models lack anatomical accuracy and exclude the presence of a brain component, limiting their ability to capture the true mechanics of concussion. To address this limitation, this research …

    clemson Repository record for Experimental Evaluation and Comparison of Football-Related Head Impacts Among Ovine, Human, and Hybrid III Headforms (opens in a new tab)

  17. Simulation-based assessment for N95 filtering facepiece respirator

    … carried out on finite element analysis between headforms and respirators. Nobody has investigated air flow characteristics within the cavity between the headform and respirator to assess respirator performance. This study focused on developing simulation-based approaches for assessing FFR …

    ttu Repository record for Simulation-based assessment for N95 filtering facepiece respirator (opens in a new tab)

  18. Quantifying the Effect of Helmet Fit on Performance

    … of this study were to quantify helmet fit on a headform and to determine the effect fit has on helmet performance. An impact pendulum was used to strike a helmeted NOCSAE headform mounted on a Hybrid III neck. Helmets were impacted at 4 locations at 3 energies representing a range of concussive …

    vt Repository record for Quantifying the Effect of Helmet Fit on Performance (opens in a new tab)

Page 1 of 5