Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 25 for “"heart assist"”

  1. Engineering external heart assist device

    … in the Department of Chemical Engineering on a heart assist device which was designed, built and tested in the laboratory. The project can be divided into a mechanical and an electrical task, both of which were undertaken by the author. The electrical task involved design and construction of a …

    cape-town Repository record for Engineering external heart assist device (opens in a new tab)

  2. Preclinical Efficacy of an Epicardial Heart Assist Device

    Of the millions of Americans with heart failure, a significant portion are end-stage and experience symptoms even at rest. Moreover, around half of people with heart failure die within 5 years of diagnosis. The ideal treatment option for these patients is a heart transplant. However, fewer than …

    tamu Repository record for Preclinical Efficacy of an Epicardial Heart Assist Device (opens in a new tab)

  3. Structural analysis of implantable biomedical heart assist device fixation

    This thesis presents how experimentation, numerical simulation, optimization, and mathematical analysis, can be applied to study and improve the fixation of left-ventricle leads within a cardiac vein. Left-ventricle cardiac leads for implantable pacemakers can lose fixation within a cardiac vein …

    umn Repository record for Structural analysis of implantable biomedical heart assist device fixation (opens in a new tab)

  4. EVALUATION & DESIGN OF A POWER CONDUIT FOR A HEART ASSIST DEVICE

    … support system for patients suffering end stage heart failure. Ventricular Assist Devices (VADs) offer hope for so many casualties of heart failure. Blood clots develop on artificial surfaces and these are the most common source of VAD morbidity. These might be avoided with a newer technology, …

    ohiolink Repository record for EVALUATION & DESIGN OF A POWER CONDUIT FOR A HEART ASSIST DEVICE (opens in a new tab)

  5. The development and investigation of a novel pulsatile heart assist device

    … to almost 30% of worldwide mortality; with heart failure being one class of CVD. One popular and widely available treatment for heart failure is the intra-aortic balloon pump (IABP). This heart assist device is used in counterpulsation to improve myocardial function by increasing coronary …

    aston Repository record for The development and investigation of a novel pulsatile heart assist device (opens in a new tab)

  6. Deep learning methods for the estimation of preload and physiological control of heart assist devices

    Heart failure (HF) is one of the most prevalent life-threatening cardiovascular diseases, affecting more than 23 million worldwide. Although heart transplantation is the gold standard treatment for end-stage HF patients, the number of donor hearts is significantly less than the demand. Mechanical …

    unsw Repository record for Deep learning methods for the estimation of preload and physiological control of heart assist devices (opens in a new tab)

  7. JOINT MICROFLUIDIC ASSESSMENT OF LOCAL SHEAR AND SHEAR HISTORICAL EFFECTS ON THROMBOSIS: APPLICATIONS TO HEART-ASSIST DEVICES AND HYPERINFLAMMATORY STATES

    Heart failure repeatedly ranks as one of the leading causes of death worldwide, and the most practical therapeutic strategy is plagued with thrombotic complications. Treatment options for these patients are heart transplantation—which is met with low supply—and heart-assist device implantation. One …

    cornell Repository record for JOINT MICROFLUIDIC ASSESSMENT OF LOCAL SHEAR AND SHEAR HISTORICAL EFFECTS ON THROMBOSIS: APPLICATIONS TO HEART-ASSIST DEVICES AND HYPERINFLAMMATORY STATES (opens in a new tab)

  8. Alternative heart assistance pump

    On average, the human heart beats around 115,000, and pumps around 2,000 gallons of blood daily. This essential organ may undergo systolic or diastolic dysfunction in which the heart cannot properly contract or relax, respectively. To help hearts pump effectively should these types of failures …

    colostate Repository record for Alternative heart assistance pump (opens in a new tab)

  9. In Vitro Flow Visualization Study of the Interface between Outflow Graft of Ventricular Assist Device and Aorta.

    Heart transplant is often considered the best treatment for prolonged left ventricular failure. However due to limited donor hearts and ineligibility of some patients to get a transplant, heart assist devices are considered a short/long term option to assist the failing ventricle. Numerous in vitro …

    vcu Repository record for In Vitro Flow Visualization Study of the Interface between Outflow Graft of Ventricular Assist Device and Aorta. (opens in a new tab)

  10. Design and Testing of a Linearly Actuated Pulsatile Pump for Ventricular Assist

    The prevalence of heart failure around the world has led clinicians and engineers to develop mechanical circulatory support systems. Most heart assist technology today is classified as continuous flow because blood is pumped in a steady stream. Though well tolerated in general, some patients …

    houston Repository record for Design and Testing of a Linearly Actuated Pulsatile Pump for Ventricular Assist (opens in a new tab)

  11. Minimally Invasive Access to the Pericardium for the Active and Adjustable Cardiac Support Device

    According to the American Heart Association, congestive heart failure affected 5.7 million Americans age 20 and older in 2006, and had an estimated direct and indirect cost of $37.2 billion in 2009. Heart assist devices are proving useful in a population where the demand for donor hearts is much …

    tamu Repository record for Minimally Invasive Access to the Pericardium for the Active and Adjustable Cardiac Support Device (opens in a new tab)

  12. Aritminis mitralinio vožtuvo prolapsas /

    … repair 15 years ago. Imaging studies of the heart assist to look for markers that help select patients with a higher risk of fatal arrhythmic event (5). Between 33 % and 78 % of the patients with malignant ventricular arrhythmias at risk of sudden cardiac death have been found to have an …

    vilnius Repository record for Aritminis mitralinio vožtuvo prolapsas / (opens in a new tab)

  13. Experimental investigation and mathematical modelling of human cardiovascular system during exercise

    … non-invasive physiological parameters such as heart rate, respiration, working rate and body movement (using multiple triaxial accelerometers). The models developed could be incorporated as part of a closed loop control system for cardiac pacemaker and/or heart assist devices. A reliable …

    unsw Repository record for Experimental investigation and mathematical modelling of human cardiovascular system during exercise (opens in a new tab)

  14. Characterization of cardiovascular-rotary blood pump interaction

    An implantable rotary blood pump (IRBP) is a. heart assist device used to support end-stage heart failure patients, either as a bridge to transplant or permanent support. The aim of this dissertation is to investigate the interaction between an IRBP and the cardiovascular system (CVS) using …

    unsw Repository record for Characterization of cardiovascular-rotary blood pump interaction (opens in a new tab)

  15. Bestimmung links- und rechtsventrikulärer Funktionsparameter mittels Elektronenstrahlcomputertomographie bei Patienten vor und nach passiver Kardiomyoplastie

    Die chronische Herzinsuffizienz gehört zu den weltweit häufigsten Erkrankungen mit steigender Inzidenz. Trotz optimaler medikamentöser Therapie ist die Lebenserwartung von Patienten mit manifester Herzinsuffizienz verkürzt. Pathophysiologisch führt eine systolische Dysfunktion des Myokards …

    fu-berlin Repository record for Bestimmung links- und rechtsventrikulärer Funktionsparameter mittels Elektronenstrahlcomputertomographie bei Patienten vor und nach passiver Kardiomyoplastie (opens in a new tab)

  16. Efficiency Evaluation of a Left Ventricular Assist Device

    Most current designs for Left Ventricular Assist Devices (LVAD) are based on rotary pumps due to their small size and lack of valves. However, the majority of FDA approved LVADs are larger, positive displacement pumps. One reason for this may be because positive displacement pumps produce pulsatile …

    vcu Repository record for Efficiency Evaluation of a Left Ventricular Assist Device (opens in a new tab)

  17. Die Wirksamkeit des psychosomatischen Liaisondienstes für Patienten vor und nach Herz- bzw. Lungentransplantation/Kunstherzimplantation aus der Sicht der Patienten – eine qualitative Analyse

    Psychosoziale Belastungen bei Patienten vor und nach Herz- bzw. Lungentransplantation/Kunstherzimplantation sind häufig. Im Gegensatz dazu ist bisher wenig über die Wirksamkeit psychologischer Interventionen im Liaisonmodell bekannt. <br>Am Universitätsklinikum Freiburg besteht seit dem 01. Januar …

    freiburg-diss Repository record for Die Wirksamkeit des psychosomatischen Liaisondienstes für Patienten vor und nach Herz- bzw. Lungentransplantation/Kunstherzimplantation aus der Sicht der Patienten – eine qualitative Analyse (opens in a new tab)

  18. A Systematic Investigation of Particle Transport Dynamics in Aortic Models.

    … grafted with the cannula of a left ventricular assist device (LVAD). AnLVAD is a mechanical heart-assist pump that is used for severe heart failure patientsawaiting heart transplants or as a permanent therapy. A risk factor with this typeof device is the transport of blood clots (formed in the …

    ohiolink Repository record for A Systematic Investigation of Particle Transport Dynamics in Aortic Models. (opens in a new tab)

Page 1 of 2