Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 265 for “"heat removal"”
-
Heat removal from a silicon chip using a liquid cooled microchannel
… to theoretically and experimentally evaluate the heat transfer characteristics of liquid forced convection i• n microchannels. An apparatus was constructed to hold and direct coolant to a 500 μm wide by 15 μm deep channel in a small silicon chip. The small dimensions of the coolant channels …
-
Thermal Transport Modeling in Three-Dimensional Pillared-Graphene Structures for Efficient Heat Removal
… element analyses were carried out by imposing a heat flux on several PGS configurations using a Gaussian pulse. The temperature gradient and distribution in the structures was evaluated to determine the optimum design for heat transfer. The microscale simulations also included conducting a …
-
Assessment of passive decay heat removal in the General Atomics Modular Helium Reactor
… dedicated to the assessment of the passive decay heat capabilities of the reactor under abnormal transient conditions. To comply with the requirements of the NGNP, fuel and structural temperatures must be kept under design safety limits under any circumstances. During the project, the MHR has been …
-
Systems interaction analysis of the Clinch River Breeder Reactor Plant Shutdown Heat Removal System
… the Clinch River Breeder Reactor Plant Shutdown Heat Removal System (CRBRP SHRS) demonstrates the application of systems interaction analysis methodology. The results of this analysis show that the CRBRP SHRS is not as redundant as previous studies have indicated. For example, previous studies …
-
Analytical and numerical study on the fast refill of compressed natural gas with heat removal
… recompression work of CNG in the cylinder that heats the fuel. The heated fuel has a lower density at the rated pressure, and thus less mass of CNG can be stored than if it was at ambient temperature. While there are many previous works that have modeled or measured the pressure, temperature …
-
Engineering the Surface Chemistry and Surface Conditions to Optimize the Heat Removal Rate of Various Surfaces
… as jet impingement cooling, spray cooling, and heat pipes, have risen in popularity for their simple design and efficiency in thermal transport. This interest has risen in both industry and academia, where research has been conducted to optimize the heat transfer performance for these systems …
-
New Heat Exchanger Modeling In The Passive Heat Removal System Of Vver-1200 Nuclear Power Plants
… an innovative methodology for modeling heat exchangers inside the passive heat removal system (PHRS) of water-water energetic reactor (VVER) nuclear power facilities. PHRS serves a crucial role in ensuring the secure and effective dissipation of residual heat produced during the shutdown …
-
DESIGN AND ANALYSIS OF AN INTERMEDIATE HEAT EXCHANGER AND PASSIVE DECAY HEAT REMOVAL SYSTEM FOR A GENERIC FLUORIDE SALT-COOLED HIGH-TEMPERATURE REACTOR APPLICATION
… Reactor (FHR), feature efficient heat transfer and passive heat removal systems. However, accurately predicting thermal behavior under steady-state and transient conditions remains challenging. This work designs and evaluates a twisted tube heat exchanger (TTHX) serving as an …
-
Optimization of cryogen spray cooling: Increasing epidermal protection during cutaneous laser procedures
… wine stains (PWS). We examined the mechanism of heat removal by CSC from skin, and heat removal was compared for CSC and contact cooling, another precooling method for cutaneous laser therapy. Next, we examined the heat removal ability of various cryogen delivery devices using a skin phantom and …
-
Fundamental study of evaporation model in micron pore
… small electronic devices has increased, heat removal from these devices for space use is approaching critical limits. A heat pipe is a promising device to enhance the heat removal performance due to the phase change phenomena for space thermal management system. Even though a heat pipe …
-
Pressurised water reactor cold shutdown transient analysis
… the reactor with the accompanying generation of heat in the megawatt range. There is a vast body of literature available investigating the occurrence of transients in reactors at varying levels of power and even hot standby, but comparatively little is available investigating transients in the …
-
An automated procedure for qualitative common cause failure analysis of complex systems
… River Breeder Reactor Plant (CRBRP) Shutdown Heat Removal System (SHRS). Under the assumptions made, the analysis shows that the Direct Heat Removal System (DHRS) is coupled to the Primary Heat Transport System (PHTS) during all phases of operation.</p><p>The common cause failure analysis was …
-
Sweeping gas membrane evaporative cooling for the enhanced performance of vapour compression refrigeration
… (SGME) cooling system was developed to remove heat from the condenser of a vapour compression chiller. The chiller was designed for hot environments and could only achieve a coefficient of performance (COP) of 1.0 using an air-cooled condenser. In this work, the condenser was modified to have …
-
Microchannel fluid flow in a silicon chip
… and Pease (1981) theorized that microscopic heat exchangers etched in the back of silicon chips could provide for efficient heat removal from the chips at rates much higher than the conventional methods could attain. The best technologies available provided for heat removal rates of 20 w/cm2 …
-
Reflux Condensation Phenomena in Single Vertical Tubes
… U-tube steam generators forms an important heat removal mechanism for nuclear reactors in certain accidents. Reflux condensation phenomena in single vertical tubes were studied for two well defined boundary conditions to develop an improved understanding of the mechanisms governing heat …
-
Direct observation of air gap formation during solidification.
… of an air gap has a somewhatsmallereffect on heat removal rates in both continuous and static castings thajv has been attributed by many previous authors.
-
Design and Feasibility Study of an Air-Cooled Reactor Cavity Cooling System for Fluoride-Salt-Cooled High-Temperature Reactors
… on passive safety systems designed for decay heat removal, yet no prior study has evaluated an air-based Reactor Cavity Cooling System (RCCS) for this role. This thesis addresses that gap by determining whether an air-cooled RCCS can be designed to passively remove post-shutdown decay heat …
Page 1 of 14