Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"helium cryostat"”

  1. Helium Cryostat for Experimental Study of Natural Turbulent Convection

    V disertační práci je popsán heliový kryostat s experimentální válcovou konvekční celou pro studium proudění při přirozené konvekci za velmi vysokých Rayleigho čísel Ra (až do řádu 10^15) a Nusseltových čísel Nu (až do řádu 10^4). Pracovní látkou je studené 4He, které umožňuje díky výhodným …

    brno-tech Repository record for Helium Cryostat for Experimental Study of Natural Turbulent Convection (opens in a new tab)

  2. The development of low temperature heat capacity results : a heat capacity study of some chloroammine cobalt(III) compounds

    … and constructed to serve a refurbished pumped-helium cryostat. Automatic data-collection, real-time display of temperature and semi-automation of heating and adiabatic control were achieved with a low-cost interface and microcomputer. The apparatus was calibrated with a benzoic acid …

    stirling Repository record for The development of low temperature heat capacity results : a heat capacity study of some chloroammine cobalt(III) compounds (opens in a new tab)

  3. Cryostat System for Spacecraft Materials Testing

    … By incorporating a two-stage, closed-cycle helium cryostat, it is now possible to simulate the temperature typical spacecraft will experience when in orbit, ranging from < 40 K to > 450 K. The system was designed to maintain compatibility with an existing ultrahigh vacuum chamber that can …

    utahstate Repository record for Cryostat System for Spacecraft Materials Testing (opens in a new tab)

  4. Growth and characterization of carbon nanowalls

    … electrode gaps in a low temperature liquid helium cryostat. Using titanium electrodes, it was found that a narrow energy band gap existing in the carbon nanowalls. Prominent fluctuations were also observed at the temperature range between 2.2 K to 200 K. With niobium electrodes, proximity …

    nus Repository record for Growth and characterization of carbon nanowalls (opens in a new tab)

  5. A Brillouin spectroscopic study of the I-II phase transition in CH₄

    … crystals of methane were grown in a liquid helium cryostat and were successfully cooled down to 15.5 K using a novel cooling technique. Lane X-ray diffraction photographs were taken to determine crystal quality and the orientation of the crystal axes. Radiation from an argon laser was …

    newfoundland Repository record for A Brillouin spectroscopic study of the I-II phase transition in CH₄ (opens in a new tab)

  6. DESIGN OF A NOVEL SAPPHIRE BASED DIELECTRIC RESONATOR TO MEASURE THE SURFACE RESISTANCE OF HIGH TEMP SUPER CONDUCTORS

    … system is designed to fit into a continuous flow helium cryostat. Real part of the surface impedance of the sample is related to the change in bandwidth, Λfb, and the imaginary part of the surface impedance is related to the change in resonant frequency, Λf0. Instead of absolute calibration of the …

    ohiolink Repository record for DESIGN OF A NOVEL SAPPHIRE BASED DIELECTRIC RESONATOR TO MEASURE THE SURFACE RESISTANCE OF HIGH TEMP SUPER CONDUCTORS (opens in a new tab)

  7. Raman and brillouin spectroscopic studies of single crystals of CH₄ and CD₄

    … single crystals of CH₄ -I and CD₄-I in a liquid helium cryostat cell, which then were successfully cooled down below the phase transition temperatures. The crystals were studied by the means of Raman and Brillouin spectroscopies. X-ray Laüe diffraction techniques were applied to determine the …

    newfoundland Repository record for Raman and brillouin spectroscopic studies of single crystals of CH₄ and CD₄ (opens in a new tab)

  8. Probing cosmic inflation with the Spider experiment

    … thousand detectors housed inside a 1300 L liquid helium cryostat, distributed amongst 6 telescopes that span two frequency channels: 95 GHz and 150 GHz. By focusing its observing time over a 10% patch of the sky at high galactic latitude, Spider targets the degree-scale BB spectrum in search of …

    toronto-retro Repository record for Probing cosmic inflation with the Spider experiment (opens in a new tab)

  9. Construction And Demonstration Of A Tandem Mass Spectrometer Based Instrument For Cold Ion Spectroscopy

    … ion trap cooled to 5 K via a closed cycle helium cryostat is used to cool the ions for spectroscopic interrogation. Results show the vibrational and rotational temperature of a wide assortment of ions to be 12±2 K. The capabilities of the instrument are confirmed using the protonated amino …

    purdue-thes Repository record for Construction And Demonstration Of A Tandem Mass Spectrometer Based Instrument For Cold Ion Spectroscopy (opens in a new tab)

  10. Design and characterization of metamaterials for terahertz region

    … characterization was done with a closed cycle helium cryostat that was installed inside the terahertz time domain spectroscopy system. Experiments were done at 20, 40, 60, 70, 80, 84, 86, 90 and 298K. At di erent temperatures a shift in the resonance frequency and change in the resonance …

    metu Repository record for Design and characterization of metamaterials for terahertz region (opens in a new tab)

  11. Optical and transport properties of polyaniline films

    … from 10-295 K are performed using a closed loop helium cryostat under dynamic vacuum (~10(^-5) mbar). From the conductivity data curves, typical fingerprints of the metallic behaviour are detected for certain samples and an initial estimate of the degree of disorder is implicitly attained. More …

    durham Repository record for Optical and transport properties of polyaniline films (opens in a new tab)

  12. Brillouin scattering experiments near the α-β phase transition in single crystals of the N₂ and CO

    … were grown in a quartz cell inside a liquid helium cryostat. Laue x-ray diffraction analysis provided for the determination of the orientations of these crystals relative to the laboratory frame of reference. An argon ion laser beam was incident on the crystal and the scattered beam was …

    newfoundland Repository record for Brillouin scattering experiments near the α-β phase transition in single crystals of the N₂ and CO (opens in a new tab)

  13. In situ synthesis studies of silicon clathrates.

    … use of laboratory x-ray diffraction and a liquid helium cryostat to test the prediction. Careful study of the region from 20 to 200 K showed a region of zero or negative thermal expansion in the predicted region the effect observed showed good agreement with theory.

    ucl Repository record for In situ synthesis studies of silicon clathrates. (opens in a new tab)

  14. Brillouin scattering in single crystals of fcc and hcp argon alloys

    … of 3 mm internal diameter situated in a liquid helium cryostat. The quality of the crystal, whether It was hcp or fcc, and its orientation with respect to the lab co-ordinates were determined by analyzing X-ray Laue transmission photographs. The light of 5145 Å from an Ar⁺ laser was incident …

    newfoundland Repository record for Brillouin scattering in single crystals of fcc and hcp argon alloys (opens in a new tab)

  15. Low-Temperature Scanning Tunneling Microscopy and Scanning Tunneling Spectroscopy Study of Hydrogen and Nitrogen Doped Nb(100) Crystals

    … through the use of a continuous flow liquid helium cryostat. Surface structural evolution and changes to the surface bandgap measured via STS were tracked over the course of many days while the crystal was kept cold. The surface bandgap was shown to significantly narrow relative to the blank …

    chicago Repository record for Low-Temperature Scanning Tunneling Microscopy and Scanning Tunneling Spectroscopy Study of Hydrogen and Nitrogen Doped Nb(100) Crystals (opens in a new tab)

  16. Low-Temperature Scanning Tunneling Microscopy and Scanning Tunneling Spectroscopy Study of Hydrogen and Nitrogen Doped Nb(100) Crystals

    … through the use of a continuous flow liquid helium cryostat. Surface structural evolution and changes to the surface bandgap measured via STS were tracked over the course of many days while the crystal was kept cold. The surface bandgap was shown to significantly narrow relative to the blank …

    chicago-thes Repository record for Low-Temperature Scanning Tunneling Microscopy and Scanning Tunneling Spectroscopy Study of Hydrogen and Nitrogen Doped Nb(100) Crystals (opens in a new tab)

  17. Some light scattering experiments in solids

    … mode. The sample was mounted in a conventional helium cryostat. Optical birefringence was used to study Tb<sub>c</sub>Gd<sub>1-c</sub>VO<sub>4</sub>; the experimental arrangement is described in this chapter. A superconducting magnet dewar was built in this laboratory for magneto-optical work, …

    oxford Repository record for Some light scattering experiments in solids (opens in a new tab)

  18. Transportní a šumové charakteristiky tranzistorů MOSFET

    Dizertační práce je zaměřená na analýzu transportních charakteristik v submikronových a mikronových tranzistorech MOSFET. Na základě předpokladu, že gradient divergence proudové hustoty v kanálu je nulový, je odvozena ampér-voltová charakteristika tranzistoru MOSFET a provedeno experimentální …

    brno-tech Repository record for Transportní a šumové charakteristiky tranzistorů MOSFET (opens in a new tab)

  19. Lattice defects and specific heats

    … was commenced is described in Chapter II. The cryostat consists of an expansion liquefier (Simon, 1932) which carries a vacuum tight radiation shield enclosing the experimental chamber. A calorimeter similar to that described by Wolcott and Smith (1956) is suspended in this experimental …

    oxford Repository record for Lattice defects and specific heats (opens in a new tab)