Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 398 for “"hemolysis"”.
-
Hemolysis in needles.
Hemolysis, the major cause for specimen rejection in clinical laboratories is defined as the rupture of red blood cell membranes, resulting in the release of hemoglobin into the plasma. Blood flow in needles causes hemolysis resulting in complications such as incorrect assay results [13,14], …
-
Computational hemodynamics: Hemolysis and viscoelasticity
… model is compared with the traditional method of hemolysis prediction in homogeneous steady and unsteady flows and inhomogeneous time-dependent flow in two-dimensional and three-dimensional blood pump. The predictions of hemolysis by the tensor-based method are found to agree well with flow-loop …
-
Improving flow-induced hemolysis prediction models.
… of red blood cell membrane, also known as hemolysis, is a persistent issue with almost all blood contacting devices. Many experimental and theoretical contributions over the last few decades have increased insight into the mechanisms of mechanical hemolysis in both laminar and turbulent …
-
Molecular Mechanisms of Hemolysis by Brachyspira hampsonii
The re-emergence of swine dysentery in Western Canadian swine herds has resulted in dramatic production losses for pork producers. The observation that pathogenic strains of the causative agents Brachyspira hyodysenteriae and Brachyspira hampsonii are strongly β-hemolytic in contrast to weakly …
-
Optofluidic Spectroscopy Platform for Detection of Hemolysis
… number of those tests are compromised due to hemolysis: e.g., 31% compromised in emergency rooms (inpatient) and 10% at blood banks, clinics, and other outpatient venues. Currently there is no way to reliably detect hemolysis without plasma separation. As a result, significant delays ensue, …
-
Analysis and experiments on flow-induced hemolysis.
Hemolysis (red cells lysis) caused by fluid stresses in flows within hypodermic needles, blood pumps, artificial hearts and other cardiovascular devices, is one of the major concerns during the design and use of cardiovascular or blood-processing extracorporeal devices. A non-invasive experimental …
-
SYNERGISTIC HEMOLYSIS IN “NON-HEMOLYTIC” BACTEROIDES SPECIES
… and identified one which was able to activate hemolysis in 30% of the collection. Using timelapse photography, we show this zone of hemolysis begins between the two colonies and proceeds in a retrograde fashion towards the ‘activated’ colony. The asymmetrical patterns of hemolysis are unlike …
-
Characterization of Shear-Induced Hemolysis in Rotational Medical Devices
The implantation of a Left Ventricular Assist Device (LVAD) is a rapidly growing means of treatment for a large variety of heart ailments. These blood pumps necessarily exert some degree of shear stress on blood passing through them, which, over time, may cause the rupture of red blood cells, …
-
Computational Prediction Of Hemolysis In Laminar Non-Newtonian Fluid
Hemolysis, the rupture of red blood cells (RBCs), is a critical concern in blood-circulating devices, requiring accurate predictions to ensure patient safety. This study investigates the sensitivity of hemolysis predictions to variations in viscosity models and hemolysis coefficients under complex …
-
A new in vitro method for evaluating intravascular hemolysis
… ratio and contact time to evaluate the degree of hemolysis occurring after an intravenous injection. The effects of both the formulation composition and the formulation:blood contact time on hemolysis are given in Chapters I-IV. Since hemolysis is shown to increase as either the formulation:blood …
-
Red blood cell hemolysis : protein biomarker discovery for product quality assessment
… One of the most prominent alterations is hemolysis, the rupturing of RBC and the subsequent release of hemoglobin-rich cytosolic content. Hemolysis may compromise the red cell concentrate (RCC) therapeutic efficacy with a decrease in viable and functional cells and an increase in bioactive …
-
Shear Stress Distribution and Hemolysis Measurements in a Centrifugal Blood Pump
… dynamics (CFO) to predict red blood cell trauma (hemolysis) in blood pumps based on their exposure to turbulent stresses has increased in recent years. The U.S. Food and Drug Administration (FDA) has initiated a project to determine the fidelity with which modern CFO can accurately predict …
-
COMPUTATIONAL INVESTIGATION OF TURBULENT BLOOD FLOW AND HEMOLYSIS IN BIOMEDICAL DEVICES
… the impact of Reynolds and viscous stresses on hemolysis prediction using computations. Also, the applicability of four different hemolysis power law models for the capillary tube flow was tested as a function of area averaged and time averaged Reynolds stresses, viscous, total, and wall shear …
-
Unraveling Macrophage Polarization: Deciphering Heme Signaling Dynamics after Hemolysis for Precision Inflammation Modulation
Hemolysis, the premature death of red blood cells (RBCs), is a common pathology in various diseases. Macrophages are essential in clearing damaged RBCs, mitigating RBC-derived hemoglobin toxicity, and recycling heme iron. Moreover, macrophages play a central role in the regulation of immune …
-
Numerical Model to Predict Hemolysis and Transport in a Membrane-Based Microfluidic Device
… the development of these devices is mechanical hemolysis and membrane diffusion, which are intricately connected to the geometry, flow rate, properties of the membrane, and each other. A computational model is developed to elucidate the connection between these phenomena to guide the design and …
Page 1 of 20