Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"high density array"”

  1. Investigation Of Breakdown Power During Electrical Breakdown Of Aligned Array Of Carbon Nanotubes

    Massively parallel arrays of single walled carbon nanotubes (SWNT) have attracted significant research interests because of their ability to (i) average out inhomogeneities of individual SWNTs, (ii) provide larger on currents, and (iii) reduce noise to provide higher cutoff frequency for radio …

    ucf Repository record for Investigation Of Breakdown Power During Electrical Breakdown Of Aligned Array Of Carbon Nanotubes (opens in a new tab)

  2. High-Resolution Array Comparative Genomic Hybridization Identifies Common Targets in Rhabdomyosarcoma

    … presents as disease of the extremities, has a higher risk of metastasis or treatment-resistance, and in 75% of cases, is characterized by the presence of the PAX3/7:FOXO1A translocation. ERMS is associated with a younger age at presentation, sites of disease other than the extremities, a more …

    utswmed Repository record for High-Resolution Array Comparative Genomic Hybridization Identifies Common Targets in Rhabdomyosarcoma (opens in a new tab)

  3. Analyzing Extracellular Vesicles as Potential Biomarkers of Stroke Using Polymer Microfluidic Devices

    … EVs, we developed a microfluidic device with a high-density array of antibody-modified micropillars for the affinity selection of CD8+ or CD15+ EVs with an analysis time less than the 4.5 h recombinant tissue plasminogen activator effective therapeu-tic time window. We successfully developed a …

    ku Repository record for Analyzing Extracellular Vesicles as Potential Biomarkers of Stroke Using Polymer Microfluidic Devices (opens in a new tab)

  4. Flexible Electronics for High-Density EMG Based Signal Acquisition for Upper Limb Myoelectric Prosthesis Control

    … is aimed at developing flexible electrodes for high-density control of an upper limb myoelectric prosthesis. Different flexible dry electrode materials (made from doped traditionally non-conductive substrates) were used and compared to titanium (which is the industry standard for EMG …

    jhu Repository record for Flexible Electronics for High-Density EMG Based Signal Acquisition for Upper Limb Myoelectric Prosthesis Control (opens in a new tab)

  5. Switchable stiffness scanning microscope probe

    … stiffness, which is needed in order to achieve high resolution imaging. The switchable stiffness probe allows the scanning of biological samples with varying surface hardness without changing probes during scanning, and therefore prevents a loss of positional information, as is unavoidable with …

    mit Repository record for Switchable stiffness scanning microscope probe (opens in a new tab)

  6. Myoelectric EEG Artifact Removal Validation Using Tripolar Concentric Ring Electrodes and Canonical Correlation Analysis

    … are fundamental challenges to the collection of high-fidelity neuroelectric signals during motion. Mobile, real-world data recordings introduce significant electrical noise that prevents the collection of high-fidelity electrical brain activity during dynamic movements. Our aim was to investigate …

    tamu Repository record for Myoelectric EEG Artifact Removal Validation Using Tripolar Concentric Ring Electrodes and Canonical Correlation Analysis (opens in a new tab)

  7. Confocal laser scanning microscopy of nanoparticles applied to immunosorbent assays

    … with multiple 30 :m layers of substrates, a high density array of immunosorbent assays was created within a stratified medium. Stacks of up to five modified thin mica substrates of model immunoassays were detected by confocal microscopy. When applied to model assays consisting of human and …

    nott-trent Repository record for Confocal laser scanning microscopy of nanoparticles applied to immunosorbent assays (opens in a new tab)

  8. Fabrication, assembly, and electrical characterisation of gold nanowire

    … oxide membrane, shown to be perforated by a high density array of isolated cylindrical pores, with a narrow size distribution. In addition, nanowires have been fabricated in commercially available porous alumina, and polycarbonate track-etched filtration membranes. Gold has been deposited by …

    whiterose Repository record for Fabrication, assembly, and electrical characterisation of gold nanowire (opens in a new tab)

  9. Integrated Genomics Of Susceptiblity To Therapy-Related Leukemia

    … Markov Model: wuHMM), to identify CNVs from high-density array comparative genomic hybridization data, accounting for the high degree of polymorphism that occur between mouse strains. Using wuHMM we analyzed the copy number content of the mouse genome: 20 strains) to a sub-10-kb resolution, …

    wustl Repository record for Integrated Genomics Of Susceptiblity To Therapy-Related Leukemia (opens in a new tab)

  10. Seismic imaging of the lithosphere-asthenosphere boundary with a dense broadband array in central California

    Lithospheric attachment to the high-velocity Isabella anomaly (IA) in central California was tested by mapping the lateral extent of interruption of the lithosphere-asthenosphere boundary (LAB). The study area spans the location of two plausible origins for the anomaly, the Monterey microplate …

    unm Repository record for Seismic imaging of the lithosphere-asthenosphere boundary with a dense broadband array in central California (opens in a new tab)

  11. STUDIO DI PATOLOGIE GENETICHE E CARATTERI DI INTERESSE A BASE EREDITARIA NEGLI ANIMALI D'AFFEZIONE

    … Future research will be directed to apply high density array (75.000 SNPs) to the research on feline hypertrophic cardiomyopathy, aiming at identifying more mutations in the affected animals and at evaluating their association with the developments of the disease. X-linked progressive …

    milano Repository record for STUDIO DI PATOLOGIE GENETICHE E CARATTERI DI INTERESSE A BASE EREDITARIA NEGLI ANIMALI D'AFFEZIONE (opens in a new tab) Restricted access

  12. Fruit to Sapling: an Ontogenetically Integrated Study of Tree Recruitment in an Amazonian Rainforest

    … a long-term seed rain dataset collected using a high-density array of seed traps, I confirmed that seed fall decreases sharply with increasing distance from fruiting trees, with disproportionately large contributions from a very small fraction of all trees. Patterns of seed fall, although …

    duke Repository record for Fruit to Sapling: an Ontogenetically Integrated Study of Tree Recruitment in an Amazonian Rainforest (opens in a new tab)

  13. Design and fabrication of a MEMS-array pressure sensor system for passive underwater navigation inspired by the lateral line

    … autonomous undersea vehicle (AUV) navigation. An array of passive underwater pressure sensors, with their ability to An object within a fluid flow generates local pressure variations that are unique and characteristic to the object's shape and size. For example, a three-dimensional object or a …

    mit Repository record for Design and fabrication of a MEMS-array pressure sensor system for passive underwater navigation inspired by the lateral line (opens in a new tab)

  14. Transition metal tolerance and the Saccharomyces cerevisiae genome

    … or in some cases two, metals. Here, I have used high density yeast arrays of a S. cerevisiae deletion collection to study the genes required for tolerance to six transition metals in parallel and I have used this data to examine the role of genes not only in the homeostasis of individual metals …

    ubc Repository record for Transition metal tolerance and the Saccharomyces cerevisiae genome (opens in a new tab)

  15. High density time-of-flight diffuse optical tomography

    … improved to millimeter-scale resolution using a higher density of sampled measurements than what has been traditionally employed. We have shown these results both with confocally captured and time-gated measurements to reduce experimental runtime, reconstruction runtime, and hardware needed for …

    rice Repository record for High density time-of-flight diffuse optical tomography (opens in a new tab)

  16. Interpreting Human Genetic Variation through Genomics and In Vivo Models

    … contribution of CNVs to disease pathology. Using high-density array comparative genomic hybridization (aCGH) we were able to identify pathogenic CNVs as small as several hundred bp. Dissection of constituent gene and in vivo experiments investigating epistatic interactions between affected genes …

    duke Repository record for Interpreting Human Genetic Variation through Genomics and In Vivo Models (opens in a new tab)

  17. Optical Trapping in Microfluidic Channels for Functional and Chemical Analysis of Single Cells

    … of more than 200 yeast cells into a high-density array of optical traps in a microfluidic chip. The cell array could be moved to specific locations of the chip enabling us to expose in a controlled manner the cells to reagents and to analyze the responses of individual cells in a …

    epfl Repository record for Optical Trapping in Microfluidic Channels for Functional and Chemical Analysis of Single Cells (opens in a new tab)

  18. Coupling electrochemistry and microfluidics for biosensor development

    … on improving the capabilities of electrode arrays as chemical imaging platforms. In this work, a platinum microelectrode system was developed for biomarker detection, primarily nitric oxide and norepinephrine. Microfluidic devices interfaced directly with the electrodes provided precise …

    colostate Repository record for Coupling electrochemistry and microfluidics for biosensor development (opens in a new tab)

  19. New RF coil arrays for Static and Dynamic Musculoskeletal Magnetic Resonance Imaging

    … nature to the possibility of obtaining high resolution images of internal organs and soft tissues. Despite tremendous advances, MR imaging of certain anatomical regions and applications present specific challenges to be overcome. One such application is MR Musculo-Skeletal Imaging. This …

    wurz-thes Repository record for New RF coil arrays for Static and Dynamic Musculoskeletal Magnetic Resonance Imaging (opens in a new tab)

  20. Developing Microelectrode Arrays as Multiplex Point-of-Care Diagnostics

    … adverse effects of unnecessary antibiotic use highlight the urgent need for better UTI diagnostics. Current state-of-the-art methods are either expensive and time-consuming, or they lack specific details about the nature of the antibiotic and only determine inflammation. This hinders timely and …

    wustl Repository record for Developing Microelectrode Arrays as Multiplex Point-of-Care Diagnostics (opens in a new tab)

Page 1 of 2