Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 89 for “"high flow rate"”.

  1. Small Footprint High Flow Rate Microdevice for Rare Target Cell Capture

    A novel high flow rate cell capture design was introduced to overcome the limitations of the current technologies or methods for rare target cell capture. Even though the rare target cell capture using BioMEMS technology has great potential for cancer diagnosis, previous rare cell capture research …

    lsu-thes Repository record for Small Footprint High Flow Rate Microdevice for Rare Target Cell Capture (opens in a new tab)

  2. Comparison of the Morphological Development of Unconfined Skewed Alluvial Laboratory Meandering Streams in Response to Low and High Flow Rate Conditions

    … later comparisons. Experiments began at a low flow condition until equilibrium was achieved, at which time the discharge was increased to a higher value until equilibrium was reached again. Data was collected for flow rate, flow depth, and bedload transport, while elevation data was obtained …

    guelph Repository record for Comparison of the Morphological Development of Unconfined Skewed Alluvial Laboratory Meandering Streams in Response to Low and High Flow Rate Conditions (opens in a new tab)

  3. High Flow Air Sampler for Rapid Analysis of Volatile and Semi-Volatile Organic Compounds

    … sorbents, which can only collect air samples at flow rates of 100-200 mL/min. In order to detect low concentration (ppt level) VOC compounds, long sampling time (>2 h) and sensitive detection are required. At the same time, portable instrumentation for on-site analysis has been developing …

    byu Repository record for High Flow Air Sampler for Rapid Analysis of Volatile and Semi-Volatile Organic Compounds (opens in a new tab) Download PDF for High Flow Air Sampler for Rapid Analysis of Volatile and Semi-Volatile Organic Compounds (opens in a new tab)

  4. Design and fabrication of bead-based microfluidic device

    … developed. These structures were essential for high efficiency immobilization and patterning of single beads. Immobilization of the microbeads was achieved by physical entrapment of the beads and patterning was performed at a relatively high flow rate. With such features, encoded microbeads can …

    nus Repository record for Design and fabrication of bead-based microfluidic device (opens in a new tab) Download file for Design and fabrication of bead-based microfluidic device (opens in a new tab)

  5. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation

    The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more …

    cape-town Repository record for Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation (opens in a new tab)

  6. Dispersion and retardation of contaminants in a high pressure liquid chromatography soil column system

    The development of a high-pressure/high-flow rate soil chromatography system as a protocol method for the rapid screening of chemicals in natural, undisturbed aquifer samples is proposed. A mathematical advective-dispersive transport model was applied which evaluated the soil column and apparatus …

    rice Repository record for Dispersion and retardation of contaminants in a high pressure liquid chromatography soil column system (opens in a new tab)

  7. Current methods of mouse euthanasia : refinements and aversion

    … painful concentrations (>40% CO₂). Various CO₂ flow rates (20, 30, 40, 50% cage vol/min) were used to examine the duration between the onset of dyspnea (identified by laboured breathing) and insensibility (identified by recumbency, loss of the righting reflex or loss of the pedal withdrawal …

    ubc Repository record for Current methods of mouse euthanasia : refinements and aversion (opens in a new tab) Download PDF for Current methods of mouse euthanasia : refinements and aversion (opens in a new tab)

  8. Φαινόμενα μεταφοράς και χημικών αντιδράσεων σε παγίδες αιθάλης με καταλυτική επίστρωση

    … due to the decrease of the filter’s porosity. At high flow rate conditions and large mean pore size substrate the amount of soot collected in the wall is larger, affecting the passive regeneration behavior of the filter. The Catalyzed Diesel Particulate Filter (CDPF) and the Diesel Oxidation …

    greece Repository record for Φαινόμενα μεταφοράς και χημικών αντιδράσεων σε παγίδες αιθάλης με καταλυτική επίστρωση (opens in a new tab)

  9. Compact and Automated Multi-solution Controller for Microfluidic Devices

    … compatible with small sample volumes and low flow rates. Assays that require a large volume of sample or a high flow rate still rely on bulky and expensive infrastructures. Here, we demonstrate a compact and automated multi-solution controller for microfluidic devices compatible with high flow …

    jhu Repository record for Compact and Automated Multi-solution Controller for Microfluidic Devices (opens in a new tab)

  10. Thrust measurement of the busek bht 20 microhall effect thruster

    … at the µN thrust level. The research presents high thrust level measurements between 1242 to 3193 µN for thruster conditions between 14.5 to 35.7 W at 413 to 474 µg/s argon flow rates with errors between 3.46 to 11.6%. Also, the discharge voltage and current operating envelope is characterized …

    alabama Repository record for Thrust measurement of the busek bht 20 microhall effect thruster (opens in a new tab)

  11. MODELING AND OPTIMIZATION OF A MICRO OPTOFLUIDIC LENS

    … found that circular chamber has the most stable flow. The simulated curvature of the micro optofluidic lens with circular expansion chamber agrees with analytical and experimental results. A rectangular expansion chamber has a shortcoming. At high flow rate ratio between core and side flow rate, …

    nus Repository record for MODELING AND OPTIMIZATION OF A MICRO OPTOFLUIDIC LENS (opens in a new tab) Download file for MODELING AND OPTIMIZATION OF A MICRO OPTOFLUIDIC LENS (opens in a new tab)

  12. Design and performance evaluation of a rotary flow control valve for independent metering hydraulics.

    … still rare, especially in application requiring high flow rates. Flow control valves are used in flow regulation and controlling of hydraulic actuators’ speed. The speed control occurs through throttling, which causes large power losses. Moreover, the substantial flow forces acting on the …

    bournemouth Download PDF for Design and performance evaluation of a rotary flow control valve for independent metering hydraulics. (opens in a new tab)

  13. OPTIMAL CONTROL OF ION EXCHANGE PROCESS FOR CHROMATE REMOVAL AND PROTEIN A CHROMATOGRAPHY FOR ANTIBODY EXTRACTION

    … or inefficient use of costly resins. Hence, accurate modeling of the ion exchange process and control strategy can enable decisions that assist in avoiding leakage when facing fluctuations in the inlet contaminant concentrations. In this work, the ion exchange process is modeled via the method of …

    rowan Repository record for OPTIMAL CONTROL OF ION EXCHANGE PROCESS FOR CHROMATE REMOVAL AND PROTEIN A CHROMATOGRAPHY FOR ANTIBODY EXTRACTION (opens in a new tab)

  14. Integrated CFD modelling for nozzle design for fog generation

    … study, describe, and predict spray generation, flow evolution from continuous stream to separated droplets is still beyond full understanding. What is more, internal nozzle flow and initial breakup that decide the characteristics of far-field spray take place inside enclosed injector, this makes …

    strathclyde Repository record for Integrated CFD modelling for nozzle design for fog generation (opens in a new tab)

  15. Characterization of preform permeability and flow behavior for liquid composite molding

    … is an important step in the processing of high-performance parts with liquid composite molding. A better understanding of preform compressibility and permeability creates more accurate process models, ultimately leading to high-quality finished composites. Without characterization, mold …

    msu Repository record for Characterization of preform permeability and flow behavior for liquid composite molding (opens in a new tab)

  16. Experimental measurements of condensate blocking and treatements in low and high permeability cores

    … blocking on gas productivity in both low and high permeability cores. Liquid dropout data for a four-component synthetic gas mixture was measured experimentally. The Peng-Robinson equation-of-state was used to calculate the liquid drop and matched the data closely after a small adjustment in …

    texas Repository record for Experimental measurements of condensate blocking and treatements in low and high permeability cores (opens in a new tab)

  17. Imprinted polymers and templated cyclic peptides : a combinatorial approach

    … New screening methods were investigated to allow high-throughput screening of the MIPs. The results suggested the mixture methacrylic acid-toluene could give efficient MIPs.</span></p> <p><span >Potential molecular imprinted polymers were prepared, by bulk polymerisation and used as HPLC …

    soton Download PDF for Imprinted polymers and templated cyclic peptides : a combinatorial approach (opens in a new tab)

  18. Determining Gravelpack Fluidization Flow Velocity

    … a gravelpack completion, non-uniform reservoir inflow with very high velocity can fluidize the gravel and/or erode the sand screen. Previous works have addressed the risks of fluidizing the gravelpack in high flow rate deepwater wells and have quantified a critical velocity above which …

    houston Repository record for Determining Gravelpack Fluidization Flow Velocity (opens in a new tab)

  19. Mixing performance of a novel, continuous confined impinging jets mixer using competitive reactions

    In this work, a novel continuous flow apparatus featuring the impingement of fluid jet streams in the presence of ultrasonic energy provided by an ultrasonic probe was tested using competitive reactions in order to determine its mixing effectiveness. The ultrasonic energy enhances micromixing of …

    njit Repository record for Mixing performance of a novel, continuous confined impinging jets mixer using competitive reactions (opens in a new tab)

Page 1 of 5