Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 34 for “"high-pass filtering"”.

  1. Investigation of High-Pass Filtering for Edge Detection in Optical Scanning Holography

    High-pass filtering has been shown to be a promising method for edge detection in optical scanning holography. By using a circular function as a pupil for the system, the radius of the circle can be varied to block out different ranges of frequencies. Implementing this system in simulation yields …

    vt Repository record for Investigation of High-Pass Filtering for Edge Detection in Optical Scanning Holography (opens in a new tab)

  2. The Measurement and Prediction of the Effect of Low-Pass and High-Pass Filtering Upon the Intelligibility of Speech in White Noise

    … range and S/N ratios used include: l) No high- pass or low-pass filter increases the intelligibility of speech in noise. 2) Speech can be low-pass or high-pass filtered at 2500Hz without significant loss of intelligibility. 3) The intelligibility of speech decreases rapidly with increasing …

    marquette Repository record for The Measurement and Prediction of the Effect of Low-Pass and High-Pass Filtering Upon the Intelligibility of Speech in White Noise (opens in a new tab)

  3. Multiple-filtering-process for the edge detection of high-dynamic-range Images

    … seriously damaged while being acquired in high dynamic range (HDR) scenes. To achieve the objective, an edge detection method based on a multiple-high-pass-filtering process scheme has been proposed. Each of the filtering processes is designed to suit one of the signal deformation …

    concordia Download PDF for Multiple-filtering-process for the edge detection of high-dynamic-range Images (opens in a new tab)

  4. Detection of symmetry and anti-symmetry : what they might reveal about visual nonlinearities

    … undetectable levels as check size decreased. The high-pass filtering of binary displays only modestly affected performance for anti-symmetrical stimuli; however, the low-pass filtering of these stimuli greatly impaired performance. Increasing the grey scale range of the stimuli led to the …

    concordia Download PDF for Detection of symmetry and anti-symmetry : what they might reveal about visual nonlinearities (opens in a new tab)

  5. Digital pulse interval modulation for indoor optical wireless communication systems

    … interference from a fluorescent lamp driven by a high-frequency electronic ballast, which is potentially the most degrading source of ambient light. It is found that such interference results in an average optical power requirement that is almost independent of the bit rate. The analysis then goes …

    sheffield-hallam Download file for Digital pulse interval modulation for indoor optical wireless communication systems (opens in a new tab)

  6. Spatial contrast sensitivity and external noise: applications to optical and neural modulation transfer functions

    … human contrast detection system comprises low-pass filtering due to ocular optics, addition of light dependent noise at the event of quantal absorption, high-pass filtering due to the neural visual pathways, addition of internal neural noise, after which detection takes place by a local matched …

    aston Download PDF for Spatial contrast sensitivity and external noise: applications to optical and neural modulation transfer functions (opens in a new tab)

  7. High Resolution Gravity, Helicopter Magnetic, and Electromagnetic Study, Haile Gold Mine, South Carolina

    … Carolina. The work focused on the calibration of high resolution gravity, and helicopter electromagnetic (EM) and magnetic data provided by OceanaGold. While high resolution potential field data (gravity and magnetics) has not been proven to be effective at small scales in exploration for …

    south-carolina Repository record for High Resolution Gravity, Helicopter Magnetic, and Electromagnetic Study, Haile Gold Mine, South Carolina (opens in a new tab)

  8. On using acousto-electric interaction effect for current mapping in denervated degenerated muscles: feasibility study, design and testing of instrumentation

    … sensor within a well defined volume a high gain amplifier is needed preferably with bipolar inputs to minimize noise, and good high pass filtering to isolate the high frequency voltage signal from the injected current. For proper quantification of the AEI signal the ultrasound bursts …

    reykjavik Repository record for On using acousto-electric interaction effect for current mapping in denervated degenerated muscles: feasibility study, design and testing of instrumentation (opens in a new tab)

  9. CMOS Readout Interfaces for MEMS Capacitive Microphones

    … and 460uA of total current consumption; thus, highlighting the feasibility of low-power integrated MCM readout interface. This ASIC is also acoustically characterized with a MCM, bonded together in a single package, demonstrating a reasonable agreement with the expected performance. The second …

    trento Repository record for CMOS Readout Interfaces for MEMS Capacitive Microphones (opens in a new tab)

  10. No change in ENSO hydroclimate variability after the industrial revolution as recorded in ?18O of Tectona grandis L.F. from Southeast Sulawesi, Indonesia

    … the period 1680-2005 (316 years) using empirical high pass filtering and random sampling of intra-annual resolution measurements. In processing this time series composite, we used Singular Spectrum Analysis (SSA) to high pass filter the data for the interannual variability associated with ENSO. …

    maryland Repository record for No change in ENSO hydroclimate variability after the industrial revolution as recorded in ?18O of Tectona grandis L.F. from Southeast Sulawesi, Indonesia (opens in a new tab)

  11. Dual-polarized filtering antennas and arrays for base stations

    … this context, the integration of dual-polarized filtering antennas has emerged as a pivotal solution in modern base station design. By employing two orthogonal polarizations, these antennas mitigate signal degradation caused by multipath interference, reflections, and polarization mismatch. This …

    kent Download PDF for Dual-polarized filtering antennas and arrays for base stations (opens in a new tab)

  12. A monitoring method for after-earthquake damage evaluation of buildings

    … residual displacements and to cancel the need of high-pass filtering acceleration signals, I proposed a sensing bar prototype instrumented with accelerometers and inclinometers.

    trento Repository record for A monitoring method for after-earthquake damage evaluation of buildings (opens in a new tab)

  13. Automated segmentation and pathology detection in ophthalmic images

    … extracts the major blood vessels by applying high-pass filtering and morphological transforms followed by addition of fine vessel pixels that are classified by a Gaussian Mixture Model (GMM) classifier. The proposed algorithm achieves more than 95% vessel segmentation accuracy on three …

    umn Repository record for Automated segmentation and pathology detection in ophthalmic images (opens in a new tab)

  14. Analog electronic computation of the finite-time Fourier transform for power spectral density measurements

    … flicker noise comer frequencies as well as high-pass filtering of the noise signal upon this ideal integration model, as well as that of the case of averaging of θ<sub>r</sub> and θ<sub>s</sub> or white noise was performed. An analysis showing the θ<sub>r</sub>- independence for the complete …

    ut-knoxville Repository record for Analog electronic computation of the finite-time Fourier transform for power spectral density measurements (opens in a new tab)

  15. Enhancement of body-conducted speech from an ear-microphone

    … thesis is concerned with the use of optimal filtering to enhance the intelligibility and quality of body-conducted speech. In the context of a mobile communication system, body-conducted speech picked up by an ear-microphone has the advantage of being immune to background noise compared to …

    soton Download PDF for Enhancement of body-conducted speech from an ear-microphone (opens in a new tab)

  16. Computer Application of Principal Component Analysis to Boundary Identification and Well-to-Well Correlation

    … improvement in the results is obtained by passing the data through a moving filter to reduce noise. Boundary identification is performed by generalized distance (D2 ) method. Cross-correlation between the filtered principal components of two boreholes is then made by matching each formation …

    glasgow Download PDF for Computer Application of Principal Component Analysis to Boundary Identification and Well-to-Well Correlation (opens in a new tab)

  17. Solid-state Raman image amplification

    … the addition of only quantum-limited noise. The high gains from SSRIA can compensate for low quantum efficiency detectors and can reduce the need for detector cooling. The range-gate of SSRIA is controlled by the pulsewidth of the pump laser and can be as short as 30-100 cm, using pump pulses of …

    arizona-thes Repository record for Solid-state Raman image amplification (opens in a new tab)

  18. Utility of Spatial Filtering Techniques in the Remote Sensing of Soil Erosion in the Sefid-Rud Reservoir Catchment in Iran

    … lines on the processed image. The next step is high pass filtering, unlike the conventional edge detection technique in which the first step is low pass filtering. In this instance, the result of low pass filtering was that faint edges, evidence of the gullies, were removed and highly eroded …

    glasgow Download PDF for Utility of Spatial Filtering Techniques in the Remote Sensing of Soil Erosion in the Sefid-Rud Reservoir Catchment in Iran (opens in a new tab)

  19. Transition to turbulence and relaminarization of pulsatile pipe flows

    … setup by using a continuous wave laser and a high-frame-rate digital camera. The position of the piston was continuously recorded by a laser proximity sensor. Different experiments were carried out with Reynolds numbers in the range of 535 4825 and Womersley numbers from 6.3 to 23.82. The …

    cuny Repository record for Transition to turbulence and relaminarization of pulsatile pipe flows (opens in a new tab)

  20. DC-EEG for routine clinical use : methods and clinical impact

    … on AC-coupled recording devices with a typical high-pass cut-off frequency at 0.5 Hz. Amplifier and electrode technology together with millivolt scale skin originated signals, have all rejected the recording of EEG signals down to DC. In the early days of EEG, high-pass filtering was introduced …

    aalto Repository record for DC-EEG for routine clinical use : methods and clinical impact (opens in a new tab)

Page 1 of 2