Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 22 for “"high-strength bolts"”
-
EVALUATION OF THE CURRENT RESISTANCE FACTORS FOR HIGH-STRENGTH BOLTS
… of bolted connections, a large quantity of high-strength structural bolts were tested. The current resistance factor in ANSI/AISC 360-05 is 0.75 for structural bolts in tension and shear, which is believed to be conservative and based on insecurities about consistent strength more than on …
-
Multi-axial fatigue strength of structural bolts in slip-critical connections under combined cyclic axial and shear demands
High-Strength bolts are used extensively in structures and are regarded as the better option for connections subjected to fatigue as compared to welds and rivets. Studies have shown the superior resistance to fatigue and conclude that it should not be an issue when a bolt is properly pre-tensioned. …
-
The Behaviour of End Plate Connections
… end of a 10WF21 beam and then bolted with four high strength bolts to the flange of an 8WF28 column. The use of electrical resistance strain gages to find bolt loads proved very satisfactory. The use of a 1/2 inch end plate proved to be sufficient for the connection. The amount of bolt …
-
Investigation of the Turn-of-Nut Installation Procedure for XTB-HX Fasteners
… procedure to a proprietary heavy hex ultra-high strength bolt hereinafter referred to as XTB-HX as produced by Nippon Steel. In order to create an objective definition of the snug-tight condition, approximately twenty percent of the maximum pretension capacity of the XTB-HX bolt was …
-
Single plate connections for steel beams
… plate connections for steel beams, connected by high strength bolts to the beam web and welded to the column, were investigated to determine their, behaviour. Tests were performed on the connections in the absence and in the presence of shear, and shear was found not to affect the rigidity of the …
-
Experimental and numerical analyses on the behavior of civil and marine steel structures
Bolts and welds in combination occur most commonly during the construction phase of a building when the design load changes, when there are unforeseen difficulties in make-up or matching of bolt holes, or in retrofit of existing structures. Due to the different load-displacement behavior of the …
-
DEVELOPMENT OF DEMOUNTABLE CONNECTORS FOR STEEL-CONCRETE COMPOSITE BEAMS
… demountable shear connector designs that achieve high strength and stiffness with minimal energy consumption and cost, while prioritizing environmental performance through disassembly and reuse. Within this framework, two novel demountable shear connectors are introduced. The first system, …
-
Análise numérica de conectores parafusos em pilares mistos circulares preenchidos com concreto
… study has the main goal evaluate the behavior of high strength bolts connectors applied in concrete-filled steel columns (CFSC). The usage of bolts as shear connectors can be regarded as a viable solution and with a great practical interest, once the bolts are easily installed in the CFSCs and are …
-
Numerical modelling and development of design rules for novel demountable steelconcrete composite bridges
… can be recycled or reused. Both connectors use high-strength bolts instead of conventional headed studs to achieve composite action. The bolts are fastened to the top flange of the steel beam using either a locking-nut (LNSC) or grouted countersunk hole configurations (FBSC) that prevent the …
-
Tension bolt behavior in moment connections for seismic applications
… has led to some recommendations aimed mainly at strengthening of the connection by making use of additional stiffeners and new welding techniques. All of this has resulted in an increase of the overall cost of this type of connection, in such a way that the previously more expensive bolted …
-
Numerical Study on the Seismic Performance of a Demountable Friction-Damped Beam-to-Column Connection for Precast Concrete Moment-Resisting Frames
… a friction damper at the beam end and employs high-strength bolts and angle steel to provide moment resistance, while corbels and shear bolts are designed to transfer shear forces. The connection features a clear load transfer path and a straightforward assembly process. Under cyclic loading, …
-
Fretting fatigue in steel bolted connections
… bolt types and surface finishes are used. A325 high strength bolts and C50LR Huck tension control bolts were used as the different bolt types. As-received mill scale steel plates (Class A surface finish) and blast-cleaned surfaces with a Cathacoat 302HB coating (Class B surface finish) were used …
-
Behavior of bolted connections during and after a fire
… program, which provide useful information on the strength of bolted connection at elevated temperature. Shear strength of A325 and A490 high strength bolts were studied with double shear tests performed at different temperature levels, from ambient temperature to 1500°F. It was found that both …
-
Fracture and Residual Capacity of Steel Bolted Connections Subjected to Singular and Consecutive Impulsive Loads
Civil structures may be subjected to high-magnitude, short-duration loads in scenarios such as weapons attacks or accidental explosions. Both during and after an impulse, the integrity of a structure is dependent on the sufficient performance of its connections. During the impulsive event, the …
-
Development of steel-timber composite system for large scale construction
… using mechanical fasteners (e.g. screws and bolts) is an attractive and novel method for developing a fully prefabricated and sustainable hybrid steel-timber composite (STC) floor that can also facilitate future dismantling and recycling of the structural components. This study concerns the …
-
The classical analysis of structural integrity and fatigue safe-life of preloaded bolted joints
… on the joint produce bending stresses in the bolts that have an effect on the fatigue life. Existing methods of calculating these bending stresses are not satisfactory. They are based on an oversimplified, and unrealistic, model which assumes bolt bearing at the holes in the flanges. This …
-
Testing of Torque-and-Angle High Strength Fasteners
… were performed on LeJeune Bolt Company’s TnA 144 high-strength structural bolt. The tensile and shear capacities of the TnA 144 were investigated as well as the effectiveness of the tightening method and hardness of the bolts. The TnA 144 has a minimum required tensile strength of 144 ksi and the …
-
Development of the Analysis and Optimization Strategies for Prediction of Residual Stresses Induced by Turning Processes
… of aircrafts, drive-shafts of automobiles, and high strength bolts and frame parts of airplanes and motorsports due to their high toughness, less sensitivity to heat, and high resistance to fatigue and corrosion. Machining these materials is accompanied by high cutting temperatures and forces, …
-
Steel fracture modeling at elevated temperature for structural-fire engineering analysis
… response, where fracture often controls both strength and deformation capacity. While advances have been made in computational prediction of the initiation and propagation of fracture in steel at room temperature, much less is known at elevated temperature. The objective of the research …
Page 1 of 2