Toxicity of metal debris from hip implants
Hip implants are commonly made of cobalt-chromium and titanium alloys. Once inside the body, implants wear and corrode, releasing metal particles and ions into the local tissue and blood. Metal debris can cause local adverse effects, such as bone loss and tissue necrosis, ultimately leading to …
-
Wear prediction in the acetabular component of hip implants
… an upsurge in thenumber of people needing total hip replacements,especiallyin younger demographics. With the average survivorship of most hip plants at fifteen years, this same trend is seen in the number of revision surgeries. Most revision surgeries are due to aseptic loosening of the implant …
-
Evaluation of Stress and Fatigue in Femoral Hip Implants
… life prediction process used to design femoral hip implants. The use of a validated FEA is needed to accurately determine the long-term survivorship success of an orthopaedic implant. This study investigates the ISO-7206-4 (2010) distal fatigue setup using a common implant configuration. Within …
-
Finite element advancements to improve performance of cementless hip implants
Radboud Universiteit Nijmegen, 06 november 2012
-
Synthesis, characterisation and corrosion studies of CoCrMo nanoparticles for hip implants
CoCrMo Metal on Metal (MoM) hip implants were designed to be durable, targeting a better quality of life for young, active patients. However, evidence suggests that such implants can release wear particles and metal ions due to a bio-tribocorrosion process. Metallic particles, produced by wear, at …
-
Long term functional simulation of large diameter metal on metal hip implants
The artificial hip replacement or total hip arthroplasty (THA), is a widely used solution to help restore hip function following arthritic disease. Pre-clinical in vitro evaluation of new designs is a vital aspect of the development of joint replacements to ensure devices are safe and to better …
-
Tribological Performance of Ceramic on Textured Polyethylene Contact for Artificial Hip Implants
Revision total hip arthroplasty (rTHA) is an expensive and surgically risky procedure that is necessary in the case of a failed primary total hip arthroplasty (pTHA). The cause of failure in artificial hip joints is often rooted in the tribological performance of the bearing surfaces such as …
-
Automating the multimodal analysis of musculoskeletal imaging in the presence of hip implants
In patients treated with hip arthroplasty, the muscular condition and presence of inflammatory reactions are assessed using magnetic resonance imaging (MRI). As MRI lacks contrast for bony structures, computed tomography (CT) is preferred for clinical evaluation of bone tissue and orthopaedic …
-
Improvement in Metal-on-Metal Bearing of Hip Implants with Advanced Stellite Alloys
CoCrMo alloy Stellite 21 has been used as hip implant material decades. However, its limited metal-on-metal bearing has resulted in loosening in hip implants. Three advanced alloys, Stellite 720, Stellite 21 with increased 10 wt%Cr (named modified Stellite 21) and Stellite 21 with additional 0.4 ~ …
-
In Vitro Macrophage Response to Nanometer-size Particles from Materials Used in Hip Implants
… osteolysis remains a major cause of hip implant failure. As polyethylene particles from conventional metal-on-polyethylene implants have been associated with these failures, an interest in lower wear metal-on-metal (MM) bearings has emerged. However, the biological effects of …
-
Computational design of functionally graded hip implants by means of additively manufactured porous materials
Two of the main mechanically related problems of hip implants are the bone resorption due to the reduction of the stresses in the bone caused by the presence of the implant (stress shielding), and the interfacial failure caused by inadequate stress distribution at the bone-implant interface. While …
-
Stress Shielding Minimized In Femoral Hip Implants A Finite Element Model Optimized By Virtual Compatibility
… a recurring problem for patients of total hip arthroplasty (THA): the bone is “shielded” from the loading it has become accustomed to over many years of development. Bone adheres to what is called “Wolff’s Law”, meaning it is an adaptive structure which adjusts its geometry based on the …
-
Immunophenotypic Analysis of Peripheral Blood and Synovial Fluid Lympocytes from Patients with Failed Hip Implants
… nature of the hypersensitivity reaction(s) MM implants remains unclear. The present study aimed to compare the phenotypes of lymphocytes from the peripheral blood and synovial fluid of patients with failed MM and MPE implants, and from volunteers with no implant (peripheral blood only). Results …
-
Investigating the effects of metal-on-metal hip implants and circulating cobalt ions on cardiovascular function
Metal-on-metal (MoM) hip arthroplasties are known to release metal ions including cobalt into the blood stream. Elevated blood cobalt at levels over 250µg/l have been shown to be a risk factor for developing cardiovascular complications including cardiomyopathy, a need for cardiac transplantation …
-
A tribological investigation into the wear and lifetime prediction of metal on plastic artificial hip implants
Artificial hip implants are a useful medical intervention for patients with a compromised hip joint. Currently, due to limitations in the longevity of the device, hip implants are often associated with use in an aging or elderly population. Despite this, there remains a potential demand in a cohort …
-
Influence of Design Parameters on Cup-Stem Orientations for Impingement free Range of Motion in Hip Implants
… the optimum positions of the prosthesis in total hip arthroplasty that produce least amount of impingement. Theoretical ranges of six basic hip motions were determined under walking, stumbling, internal rotation at 90 flexion and external rotation at 0 extension with 15 abduction, using …