Showing 1 to 10 of 10 for “"hip joint simulator"”.
-
The morphology of UHMWPE wear debris generated by a hip joint simulator
The size, quantity and shape of total hip replacement wear debris may identify wear mechanisms as well as play a role in osteolysis. Characterization of wear particles generated from a hip joint simulator was conducted followed by comparison with literature reported in vivo results. The effect of …
-
The tribological significance of the joint fluid analog in a hip joint simulator
… with regards to the longevity of THR (total hip replacement). Therefore, reliable in-vitro prediction of wear is necessary. Thus, the laboratory should first validate their hip simulators with known clinical materials. The limiting factor in hip wear simulation has been the joint fluid …
-
Tribocorrosion of total hip replacements
The performance of metal-on-metal total hip replacements is largely determined by their propensity to degrade in vivo. Degradation occurs through the complex interactions between wear and corrosion (termed tribocorrosion) and leads to the production of metallic particulate debris and metallic ions. …
-
The Effect of Variations in Component Positioning and Swing Phase Load on the Occurrence and Severity of Edge Loading and Wear in Hip Joint Replacements
… identified as a risk leading to the revision of hip joint replacements. Pre-clinical testing requirements currently do not incorporate edge loading. Previous testing of edge loading has been carried out as controlled dynamic microseparation of 0.5 mm via a spring, where the femoral head contacts …
-
Simulation and anylysis of the wear of metal on metal articulations in artificial hip joints
Metal on metal articulations used in hip joint replacement were demonstratedth rough the 1960's and 70's to perform adequately and comparably to metal on plastic articulations but their use then fell into decline as orthopaedic surgeons preferred metal on polyethylene articulations. However, one of …
-
Wear of hard-on-hard hip prostheses: influence of head size, surgical position, material and function
Edge loading in hip replacement bearings may occur due to rotational and translational mal-positioning. Rotational mal-positioning is easier to detect clinically which include steep inclination angle and excessive version/anteversion angles. Translational mal-positioning encompasses …
-
Experimentální stanovení vlivu orientace polyetylénového acetabula na vývoj plastických deformací v počáteční fázi opotřebení
Diplomová práce je zaměřena na počáteční fázi opotřebení celkové náhrady kyčelního kloubu s polyethylenovým acetabulem. V této fázi dochází k přizpůsobování artikulačních povrchů náhrady a k nezanedbatelným plastickým deformacím acetabula, které jsou způsobené tečením (creepem). Experimentálně je …
-
Konstrukce simulátoru kyčelního kloubu
Diplomová práca sa zaoberá návrhom a realizáciou experimentálneho simulátora bedrového kĺbu. Primárne využitie je štúdium hrúbky mazacieho filmu v umelých bedrových náhradách pomocou metódy interferometrie. Sekundárna je aplikácia pre štúdium dlhodobého opotrebenia umelých bedrových náhrad. Práca …
-
Konstrukce simulátoru umělého kyčelního kloubu
V práci je popsán jeden z možných přístupů k návrhu simulátoru kyčelního klubu, primárně určeného pro analýzu tloušťky mazacího filmu ve styku dvou konformně zakřivených povrchů (hlavy femuru a acetabula). Při relativním pohybu těchto dvou komponent umělých kyčelních kloubů je třeba pozorovat …