An analysis of choice: a case study on hip prostheses
Total hip replacement (THR) surgery is a highly successful procedure offering relief of chronic pain and improving physical functioning. Given an ageing population, there is an ever increasing demand for THR, and an increasing need to establish its cost-effectiveness. This thesis explores two …
-
Prostate high dose-rate brachytherapy in men with bilateral hip prostheses.
Bilateral hip prostheses challenge the acquisition of clinically useful treatment planning images for prostate HDR brachytherapy. Prostheses can introduce severe artifact into the principal modalities used for HDR prostate brachytherapy imaging – ultrasound, magnetic resonance imaging (MR) and …
-
Wear reduction in modular taper-trunnion hip prostheses using straight cylindrical stems
… (head-stem) junction of modular metallic total hip replacement (THR) implants contributes to high rates of metallosis and reduced durability. Currently in THR, tapered stems are employed which are press-fitted by impaction into the ball-head. Any pull-out movement between the two components will …
-
A qualitative holographic study of hemipelvic and acetabular deformation caused by different hip prostheses
… complication resulting in failure of Total Hip Arthroplasty. The mechanical behaviour of bone under load is one of the contributory causes of loosening encountered at the prosthesis/cement/bone interface. The present study dealt with a series of invitro experiments conducted on epoxy resin …
-
A computerized pre-clinical test for cemented hip prostheses based on finite element techniques
Despite the success of cemented total hip replacement (THR), high failure rates are occasionally reported for cemented hip implants that are introduced on the orthopaedic market. Rigorous pre-clinical testing of hip implants could prevent these disasters, by detecting unsafe implant designs at a …
-
A Computerized Pre-Clinical Test for Cemented Hip Prostheses Based on Finite Element Techniques
Item does not contain fulltext
-
Morphology and Localisation of Patient Hip Replacement-Derived Debris and Hip Prostheses Materials in Macrophages
Whilst total hip replacement and hip resurfacing arthroplasties have been largely successful to relieve pain and restore mobility for patients, aseptic loosening is still the most common cause for revision surgery. It is thought there is a contribution from both the sensitivity to the debris …
-
THE SURFACE AND SUBSURFACE CHARACTERIZATION OF RETRIEVED METAL-ON-POLYETHYLENE HIP PROSTHESES USING ELECTRON MICROSCOPY
… half a century ago, metal-on-polyethylene (MoP) hip prostheses have become the gold standard for total hip arthroplasty (THA), a surgical intervention for degenerative hip joint conditions. The accumulation of polyethylene wear debris after long-term, in vivo articulations, can induce adverse …
-
Evaluation of a deterministic Boltzmann solver for radiation therapy dose calculations involving high-density hip prostheses
… scatter within a high-density volume, such as a hip prosthesis. Until now, the only way to accurately model high-density scatter was with a Monte Carlo simulation which gives the stochastic solution to the same transport equation, but is time and computationally expensive. In contrast, Acuros XB …
-
Wear of hard-on-hard hip prostheses: influence of head size, surgical position, material and function
Edge loading in hip replacement bearings may occur due to rotational and translational mal-positioning. Rotational mal-positioning is easier to detect clinically which include steep inclination angle and excessive version/anteversion angles. Translational mal-positioning encompasses …
-
Inflammation and Corrosion in Total Hip Prostheses: The Generation and Interaction of Reactive Oxygen Species with CoCrMo Metallic Biomaterial Surfaces
There are many molecules, species and mechanisms that contribute to the overall wear and degradation of biometallic alloys like cobalt-chromium-molybdenum (CoCrMo). Following implantation, orthopaedic alloys are subject to an encompassing inflammatory response that will either lead to foreign body …
-
Hip joint forces in hip replacement patients and normal subjects during activities of daily living
A high number of revision hip replacement operations are currently performed due to loosening of the primary implant. The loading imposed on the prosthetic joint and its fixation mechanisms may be one of the many factors contributing to the loosening process. Previous work to determine hip joint …
-
Friction and lubrication behaviour of metal-on-metal and ZTA ceramic-on-CFR PEEK hip prostheses. Friction and lubrication behaviour of metal-on-metal hip resurfacing and ZTA ceramic heads versus CFR PEEK cups wiith various diameters and clearances using serum-based lubricants with various viscosities.
The natural hip joint in healthy people has a very low friction with very little (or no) wear. It works as a dynamically loaded bearing and is subjected to about 1-2 million cycles of loading per year. The applied load is the body weight which is tripled when walking and even higher during other …
-
Design and Prototype Validation of a Laterally Mounted Powered Hip Joint for Hip Disarticulation Prostheses
Powered prostheses are at the forefront of prosthetic technology, improving functionality by providing positive power to joints in the absence of native anatomy. Currently, there is no commercially available powered solution for hip-level amputees, and most hip prostheses are mounted to the front …
-
Performance simulation of a composite orthopedic implant device
… strength and long-term performance of composite hip prostheses under complex mechanical and environmental loading conditions are studied through theoretical modelling and experimental investigations. Two static strength models, namely, a cantilever beam model and an elastic foundation model, were …
-
Clinical Significance of Hip Separation in Metal on Polyethylene, Metal on Metal, and Ceramic on Ceramic THA Due to Resonant and Energy Dispersion Effects
… to synthetic bones which had been implanted with hip prostheses. Data was collected from these sensors as a machine impacted the femoral head into the acetabular cup. These tests were carried out for metal-metal, ceramicceramic, and metal-polyethylene bearing surfaces at varying loads. Contrary to …