Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 92 for “"hip replacements"”.

  1. Impingement in total hip replacements

    … most common reason for early failure in total hip replacements (THRs) and occurs following impingement. Impingement is the unwanted contact between either the component and/or bone around the THR. This thesis investigates the effect of factors such as patient bony anatomy, patient activity and …

    whiterose Download PDF for Impingement in total hip replacements (opens in a new tab)

  2. Torques in total hip replacements

    … torques at the articulating interface of total hip replacements (THRs), if transferred, have the potential to affect component fixation and/or induce micro motion linked to fretting and corrosion at modular junctions. Pre-clinical testing of friction behaviour in THRs has predominantly been …

    whiterose Download PDF for Torques in total hip replacements (opens in a new tab)

  3. Tribocorrosion of total hip replacements

    The performance of metal-on-metal total hip replacements is largely determined by their propensity to degrade in vivo. Degradation occurs through the complex interactions between wear and corrosion (termed tribocorrosion) and leads to the production of metallic particulate debris and metallic ions. …

    whiterose Download PDF for Tribocorrosion of total hip replacements (opens in a new tab)

  4. Integrating sensors into total hip replacements

    Total hip replacement (THR) is a successful intervention for late stage osteoarthritis. The NJR reported in 2022, that 100,000 total hip replacement (THR) surgeries were performed in England, Wales and N.Ireland . Use of THR is increasing and younger patients are receiving THRs. Implants need to be …

    whiterose Download PDF for Integrating sensors into total hip replacements (opens in a new tab)

  5. Contact mechanics of metal on polyethylene hip replacements

    … molecular weight polyethylene (UHMWPE) total hip replacement (THR) has been the most popular and clinically successful hip prosthesis to date. The long-term performance of THR depends on both the tribological characteristics and biomechanical behaviour of the prosthesis. This project focused …

    whiterose Download PDF for Contact mechanics of metal on polyethylene hip replacements (opens in a new tab)

  6. Polyethylene acetabular liner rim damage in total hip replacements

    Total hip replacement surgery is a successful orthopaedic intervention with over 90,000 procedures carried out annually; however, some implants still fail. The failure of THRs in the first year have been related to mechanical failure, such as dislocation and/or implant fracture. The mechanical …

    whiterose Download PDF for Polyethylene acetabular liner rim damage in total hip replacements (opens in a new tab)

  7. Corrosion associated failure mechanisms of CoCrMo alloys in total hip replacements

    Over one million hip replacements are performed worldwide to restore hip mobility every year. CoCrMo alloys are widely used in hip implants because of their excellent corrosion resistance and mechanical properties. However, some complications related to corrosion of CoCrMo alloys emerged, leading …

    ubc Repository record for Corrosion associated failure mechanisms of CoCrMo alloys in total hip replacements (opens in a new tab) Download PDF for Corrosion associated failure mechanisms of CoCrMo alloys in total hip replacements (opens in a new tab)

  8. Retrieval Analysis of Necropsy Total Hip Replacements: Considerations Beyond the Implant

    Introduction. Total hip arthroplasty (THA) surgery is one of the most commonly performed and successful orthopedic procedures in the United States. More than 300,000 primary THAs and 40,000 revision THAs performed in the United States every year. While the need for revision surgeries can stem from …

    tenn-hsc Repository record for Retrieval Analysis of Necropsy Total Hip Replacements: Considerations Beyond the Implant (opens in a new tab)

  9. A General Wear Algorithm for Wear Predictions in Total Hip Replacements

    Total hip replacements are known to be one of the most successful orthopaedic interventions of all time when the hip joint becomes damaged due to disease or trauma. Currently, these hip prostheses have a lifespan of approximately 15 years, however, according to the National Joint Registry (NJR) in …

    liverpool-jm Repository record for A General Wear Algorithm for Wear Predictions in Total Hip Replacements (opens in a new tab) Download PDF for A General Wear Algorithm for Wear Predictions in Total Hip Replacements (opens in a new tab)

  10. A COMPUTATIONAL APPROACH TO FRETTING WEAR PREDICTION IN TOTAL HIP REPLACEMENTS

    … occurs at the taper junction of modular total hip replacements and leads to failure of the implants. Experimental testing to determine the wear behaviour that occurs in mechanical devices is time consuming, expensive and complicated. Computational wear modelling is an alternative method which …

    liverpool-jm Repository record for A COMPUTATIONAL APPROACH TO FRETTING WEAR PREDICTION IN TOTAL HIP REPLACEMENTS (opens in a new tab) Download PDF for A COMPUTATIONAL APPROACH TO FRETTING WEAR PREDICTION IN TOTAL HIP REPLACEMENTS (opens in a new tab)

  11. Biotribocorrosion of Hard-on-Hard Bearing Surfaces in Orthopaedic Hip Replacements

    … 28 mm Metal-on-Metal and Metal-on-Ceramic Total Hip Replacement components under these ‘adverse loading’ scenarios, two hip simulators were instrumented with three-electrode electrochemical cells. Various DC electrochemical analysis techniques, including Linear Polarisation Resistance and …

    whiterose Download PDF for Biotribocorrosion of Hard-on-Hard Bearing Surfaces in Orthopaedic Hip Replacements (opens in a new tab)

  12. Fretting-crevice corrosion of cemented metal on metal total hip replacements

    … use of 2nd generation Metal-on-Metal (MoM) Total Hip Replacements (THRs) recently became popular due to the advancement of new materials and manufacturing processes promising improved performance compared to traditional metal on metal total hip replacements. The Ultima TPS MoM THR was designed and …

    whiterose Download PDF for Fretting-crevice corrosion of cemented metal on metal total hip replacements (opens in a new tab)

  13. An Investigation on the Corrosion Susceptibilities of Multi-Alloy Total Hip Replacements.

    … there is a design for a total hip replacement prosthesis which combines titanium-aluminum-vanadium and cobalt-chromium-molybdenum surgical alloys in contact. There are several mechanical design considerations that indicate such a design to be favorable. For example, fatigue …

    uab Repository record for An Investigation on the Corrosion Susceptibilities of Multi-Alloy Total Hip Replacements. (opens in a new tab)

  14. Assessment of Bore-Cone Taper Junctions in Explanted Modular Total Hip Replacements

    For people with chronic hip pain due to arthritis or other conditions, a total hip replacement (THR) is a common procedure used to eliminate the pain. Due to the natural variation in patient anatomy, THR prostheses are becoming increasingly more modular to allow for a more customized initial …

    clemson Repository record for Assessment of Bore-Cone Taper Junctions in Explanted Modular Total Hip Replacements (opens in a new tab)

  15. Characterisation and Biological Impact of Wear Particles from Composite Ceramic Hip Replacements

    … of conventional metal-on-UHMWPE (MoP) total hip replacements (THRs), and concerns over the release of metal wear particles and metal ions around the body from metal-on-metal (MoM) THRs, led to the development of alternative ceramic-on-ceramic (CoC) THRs. CoC bearings are of great interest due …

    whiterose Download PDF for Characterisation and Biological Impact of Wear Particles from Composite Ceramic Hip Replacements (opens in a new tab)

  16. Modelling of Dynamic Edge Loading in Total Hip Replacements with ceramic on polyethylene Bearings

    The performance of total hip replacement (THR) devices can be affected by various factors such as quality of the tissues surrounding the joint, mismatch of the component centres or the cup positioning during hip replacement surgery. Experimental studies have shown that these factors can cause the …

    whiterose Download PDF for Modelling of Dynamic Edge Loading in Total Hip Replacements with ceramic on polyethylene Bearings (opens in a new tab)

Page 1 of 5