Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 67 for “"hold-down"”.

  1. Development of a high-performance hybrid steel-grout hold-down connection for mass timber panels

    This dissertation explores the structural performance and predictive modeling of hybrid steel-grout connectors for cross-laminated timber panels, addressing critical challenges in mass construction. The hybrid connector consists of a thick layer of epoxy-based grout that surrounds a steel rod. A …

    ubc Repository record for Development of a high-performance hybrid steel-grout hold-down connection for mass timber panels (opens in a new tab) Download PDF for Development of a high-performance hybrid steel-grout hold-down connection for mass timber panels (opens in a new tab)

  2. Characterisation and modelling of degradation mechanisms in RF MEMS capacitive switches during hold-down operation

    … in RF MEMS capacitive switches. A bipolar hold-down technique is used to minimise the effects of dielectric charging and allow mechanical degradation to be studied in isolation in aluminium-based capacitive switches. An investigation of mechanical degradation leads to the identification of …

    cork Repository record for Characterisation and modelling of degradation mechanisms in RF MEMS capacitive switches during hold-down operation (opens in a new tab)

  3. Effect of rotational stiffness on the behavior of integral abutments on prestressed concrete piles

    … of an actual bridge, the testing setup utilized hold-down beams to provide the rotational restraint of the simulated abutment during lateral displacements. The research team utilized four different hold-down setups, each providing a different rotational stiffness. Equations for the theoretical …

    ut-knoxville Repository record for Effect of rotational stiffness on the behavior of integral abutments on prestressed concrete piles (opens in a new tab)

  4. Midply shear walls use in non-residential buildings

    … the evaluation of the design and performance of hold-down connections at the boundary end studs of the MIDPLY shear wall. Previously tested MIDPLY shear walls showed that the boundary end stud hold-down connection is a very critical component in the performance of the MIDPLY shear wall. After a …

    ubc Repository record for Midply shear walls use in non-residential buildings (opens in a new tab) Download PDF for Midply shear walls use in non-residential buildings (opens in a new tab)

  5. Kinematic Behaviour of Cross Laminated Timber (CLT) Shearwalls with Openings

    … the mechanical properties and configurations of hold-downs on both elastic and inelastic behaviours including the possible kinematic modes of the shearwalls are investigated. The research also proposes the concept of equivalent-frame-model applicable for shearwalls where openings are cut-out from …

    ottawa-retro Repository record for Kinematic Behaviour of Cross Laminated Timber (CLT) Shearwalls with Openings (opens in a new tab)

  6. Testing and analysis of Midply(TM) Shear Wall System

    … schedules. Several anchoring techniques and hold-down connectors have been developed and tested. The tests were performed mainly on 2.44m x 2.44m and 1.22m x 2.44m MIDPLY™ shear walls. In the investigations covered by this thesis, were designed and tested 30 walls and were primarily studied: …

    ubc Repository record for Testing and analysis of Midply(TM) Shear Wall System (opens in a new tab) Download PDF for Testing and analysis of Midply(TM) Shear Wall System (opens in a new tab)

  7. Nonlinear dynamic assessment of mid-rise light-frame wood shear walls under horizontal and vertical ground motions

    … constructed with discrete and continuous rod hold-down systems. For this purpose, a numerical model has been developed and series of comprehensive nonlinear time-history analyses are conducted in SAP2000 software. Maximum inter-story drifts are estimated and compared under different earthquake …

    uvic Repository record for Nonlinear dynamic assessment of mid-rise light-frame wood shear walls under horizontal and vertical ground motions (opens in a new tab)

  8. Performance Capabilities of Light-Frame Shear Walls Sheathed With Long OSB Panels

    … of shear walls with and without a mechanical hold-down device attached to the base of the end stud. An advantage of the long panel was investigated in which it was extended past the bottom plate and down onto the band joist to determine if significant resistance to the uplift present in walls …

    vt Repository record for Performance Capabilities of Light-Frame Shear Walls Sheathed With Long OSB Panels (opens in a new tab)

  9. An Investigation of Splaying in Redrawing

    … whether redrawing is conducted with or without a hold-down punch to prevent wrinkling during deformation. Both situations, (termed constrained redrawing and unconstrained redrawing respectively), were investigated from a splaying aspect. Splaying was related to that deformation in the cup which …

    aston Download PDF for An Investigation of Splaying in Redrawing (opens in a new tab)

  10. System Level Interactions and Floor Diaphragm Out-of-Plane Stiffness Effects on the Lateral Response of Light Frame Wood Shear Walls

    … types of anchorage systems (e.g., discrete hold-downs and continuous rods), shear wall aspect ratio, and wall-to-floor boundary conditions. A numerical modelling framework incorporating system-level effects was developed and validated using the results from the single-storey shear wall …

    ottawa-retro Repository record for System Level Interactions and Floor Diaphragm Out-of-Plane Stiffness Effects on the Lateral Response of Light Frame Wood Shear Walls (opens in a new tab)

  11. Reliability and effect of partially restrained wood shear walls

    … either a restraining dead load or a mechanical hold down device to resist overturning. To prescribe a safe structure, it is important to know the effect of partial restraint on the overturning resistance of wood shear walls constructed in accordance with the IRC and equally important whether the …

    wayne-thes Repository record for Reliability and effect of partially restrained wood shear walls (opens in a new tab)

  12. Study of Deflection of Single and Multi-Storey Light Frame Wood Shear Walls

    … spacing, sheathing panel type and thickness and hold-down anchoring system/type. For the two-storey walls, two different loading cases were considered, namely where the load was applied at the top or bottom storey only. The results showed that the strength and stiffness correlated almost directly …

    ottawa-retro Repository record for Study of Deflection of Single and Multi-Storey Light Frame Wood Shear Walls (opens in a new tab)

  13. Analytical Methodology to Predict the Behaviour of Multi-Panel CLT Shearwalls Subjected to Lateral Loads

    … wall) could be achieved if the yielding in the hold-down occurred prior to yielding in the panel joints. Inversely, the other behaviour (i.e. coupled panels) was achieved if the yielding in the vertical joint occur prior to yielding in the hold-down. The analytical model was validated using a …

    ottawa-retro Repository record for Analytical Methodology to Predict the Behaviour of Multi-Panel CLT Shearwalls Subjected to Lateral Loads (opens in a new tab)

  14. Analytical Model for Lateral Deflection in Cold-formed Steel Framed Shear Walls with Steel Sheathing

    … displacement, steel sheet deformation, and hold-down deformation, which are from the effective strip concept and a complexity factor, which accounts for the additional influential factors not considered in the previous three terms. The model uses design equations based on the actual material …

    unt Repository record for Analytical Model for Lateral Deflection in Cold-formed Steel Framed Shear Walls with Steel Sheathing (opens in a new tab)

  15. Design, fabrication, and assembly of a test platform for a high-speed GaAs DRAM VLSI IC

    … circuit test fixture and the design of the DRAM hold down clamp necessary to affix the DRAM to the test fixture. The use of commercially available Computer Aided Design (CAD) and Computer Aided Manufacturing CAM) tools were used for layout and fabrication. Finally, the assembly and testing of the …

    nps Repository record for Design, fabrication, and assembly of a test platform for a high-speed GaAs DRAM VLSI IC (opens in a new tab)

  16. Study of Timber-frame Building Seismic behaviour by Means of numerical modelling and Full-scale shake table testing

    … devices (i.e. fasteners, angle brackets and hold-down). Particular attention was paid to the ductility of each component. Secondly, a numerical modelling for the seismic linear analysis of multi-storey walls is proposed. In this section the horizontal force distribution between the walls is …

    trento Repository record for Study of Timber-frame Building Seismic behaviour by Means of numerical modelling and Full-scale shake table testing (opens in a new tab)

  17. Coupling effects of CLT connections under bi-axial loading

    … loads (0 kN, 20 kN, 30 kN, and 40 kN), 3) HTT5 hold-down connection tests under monotonic/cyclic tension loading with three levels of co-existent shear loads (0 kN, 10 kN, and 20 kN), and 4) HTT5 hold-down connection tests under monotonic/cyclic shear loading with five levels of co-existent …

    ubc Repository record for Coupling effects of CLT connections under bi-axial loading (opens in a new tab) Download PDF for Coupling effects of CLT connections under bi-axial loading (opens in a new tab)

  18. Experimental Testing and Numerical Modeling of a Novel Buckling Restrained Connection for Mass Timber Structures

    … drifts below the limit of 2.5% while hold-down displacements were less than 10% of the core length. Comparing the performance of a structure with the buckling restrained connection to a more traditional self-tapping screw connection demonstrated that the buckling restrained connection …

    queens Repository record for Experimental Testing and Numerical Modeling of a Novel Buckling Restrained Connection for Mass Timber Structures (opens in a new tab)

  19. Development of a model of the anisotropic dimensional change on sintering

    … and compaction parameters (compaction speed hold down force and hold down time) on the anisotropy of dimensional changes on sintering were investigated. Ring shaped parts made of eight different iron-based materials were investigated in order to cover a large range of dimensional changes and …

    trento Repository record for Development of a model of the anisotropic dimensional change on sintering (opens in a new tab)

Page 1 of 4