Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"hollow waveguide"”.

  1. Low-Loss Hollow Waveguide Platforms for Optical Sensing and Manipulation

    … presents a method for fabricating integrated hollow and solid optical waveguides on planar substrates. These waveguides are antiresonant reflecting optical waveguides (ARROWs), where high-index cladding layers confine light to hollow cores through optical interference. Hollow waveguides that …

    byu Repository record for Low-Loss Hollow Waveguide Platforms for Optical Sensing and Manipulation (opens in a new tab) Download PDF for Low-Loss Hollow Waveguide Platforms for Optical Sensing and Manipulation (opens in a new tab)

  2. Low-Photoluminescence Hollow Waveguide Platforms for High-sensitivity Integrated Optical Sensors

    … sensor platforms, which consist of integrated hollow waveguides and solid waveguides. Antiresonant reflecting optical waveguides (ARROWs) filled with liquids or gases, can be used for high-sensitivity sensing in applications of biotechnology, chemical synthesis, and analytical chemistry. The …

    byu Repository record for Low-Photoluminescence Hollow Waveguide Platforms for High-sensitivity Integrated Optical Sensors (opens in a new tab) Download PDF for Low-Photoluminescence Hollow Waveguide Platforms for High-sensitivity Integrated Optical Sensors (opens in a new tab)

  3. Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and nonimaging optics

    The application of a hollow waveguide (HW) was investigated as a gas cell for analytical infrared analysis. The analysis was the measurement of carbon monoxide (CO) and nitric oxide (NO) in sidestream cigarette smoke. An FT-IR analysis system was setup with a 3m multi-pass gas cell and a 55cm by …

    gatech Repository record for Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and nonimaging optics (opens in a new tab)

  4. Development of chemical sensors using novel infrared sources

    … into a silver halide optical fibre and a hollow waveguide, for liquid water and gaseous propylene sensing, respectively. The second laser, a Fabry-Perot device emitting at 5.625/im, was used for acetone, acetic acid and formaldehyde sensing using open path optical cells and a hollow …

    dcu Download PDF for Development of chemical sensors using novel infrared sources (opens in a new tab)

  5. Controlling light with metadevices

    … requirements. A hyperbolic metamaterial and a hollow waveguide with negative index metamaterial cladding that satisfy the vertical connectivity requirement are proposed, and hence they have the potential to be fabricated with DLW. Three different magnetic dipoles supported by the hyperbolic …

    mtu Repository record for Controlling light with metadevices (opens in a new tab)

  6. On-Chip Atomic Spectroscopy

    … cells with anti-resonant reflecting optical waveguides (ARROWs) fabricated on silicon chips. These potentially provide a compact platform for a number of optical applications, including the study of quantum coherence effects such as electromagnetically induced transparency and single-photon …

    byu Repository record for On-Chip Atomic Spectroscopy (opens in a new tab) Download PDF for On-Chip Atomic Spectroscopy (opens in a new tab)

  7. Improved Systems For On-Site Raman Measurements

    … MCC devices. The second method involves new hollow waveguide (HWG) designs, and a new gas chamber coupled to a dispersive Raman spectrometer with a new type of fiber optic Raman probe.

    south-carolina Repository record for Improved Systems For On-Site Raman Measurements (opens in a new tab)

  8. Laser chemical etching of waveguides and quasi-optical devices

    … to astronomers. Near THz frequencies, metallic hollow waveguide structures become so small, (typically much less than a millimeter), that conventional machining becomes extremely difficult, and in many cases, nearly impossible. Laser induced, micro-chemical etching is a promising new technology …

    arizona-thes Repository record for Laser chemical etching of waveguides and quasi-optical devices (opens in a new tab)

  9. Evanescent wave spectroscopy using hollow cylindrical waveguide probes

    Optical waveguides carry bound modes which consist of a core E and H field, winch is oscillatory across the waveguide and evanescent in the waveguide cladding. Both the core and cladding component of each mode has the same frequency and propagation constant. When the frequency of the light earned …

    dcu Download PDF for Evanescent wave spectroscopy using hollow cylindrical waveguide probes (opens in a new tab)

  10. Improved control of single cycle pulse generation by molecular modulation

    … in deuterium we have shown that employing a hollow waveguide instead of normal Raman cell improves the efficiency of the generation process. By optimizing gas pressure and waveguide geometry to compensate the dispersion, the method can be extended to efficiently generate Raman sidebands at a …

    tamu Repository record for Improved control of single cycle pulse generation by molecular modulation (opens in a new tab)

  11. Integration of Micropore and Nanopore Features with Optofluidic Waveguides for Single Particle Sensing

    … this work is an antiresonant reflecting optical waveguide (ARROW). ARROW hollow and solid core waveguides are interference based waveguides that are designed to guide light in low index media such as liquids and gases. Because of this unique guiding property, ARROW hollow cores can be used to …

    byu Repository record for Integration of Micropore and Nanopore Features with Optofluidic Waveguides for Single Particle Sensing (opens in a new tab) Download PDF for Integration of Micropore and Nanopore Features with Optofluidic Waveguides for Single Particle Sensing (opens in a new tab)

  12. Fabrication of 3D microwave and millimetre-wave components in LTCC technology

    … microwave fabrication requirements. To fabricate hollow waveguide in LTCC, the standard LTCC process has been considered, and it was found unable to produce suitable channels/cavities. The hurdle was the lamination step. Experiments on lamination pressure, temperature, time duration and number of …

    whiterose Download PDF for Fabrication of 3D microwave and millimetre-wave components in LTCC technology (opens in a new tab)

  13. FT-IR and quantum cascade laser spectroscopy towards a hand-held trace gas sensor for benzene, toluene, and xylenes (BTX)

    … levels of BTX. Using direct absorption through a hollow waveguide, parts-per-million (ppm) detection limits for BTX with a response time of 39 seconds was demonstrated. Univariate calibration provided limits of detection (3σ) for benzene, toluene, and meta-xylene at 5, 17, and 11 ppm, …

    gatech Repository record for FT-IR and quantum cascade laser spectroscopy towards a hand-held trace gas sensor for benzene, toluene, and xylenes (BTX) (opens in a new tab)

  14. Wideband air-filled waveguide antennas

    … communication, and radar systems, air-filled hollow waveguide array antennas have become a mainstream choice due to their low loss and high-gain characteristics. Meanwhile, dual-polarized antennas, with their ability to provide polarization diversity and enhance channel capacity in multipath …

    birmingham Download PDF for Wideband air-filled waveguide antennas (opens in a new tab)

  15. Entwicklung und Aufbau eines sub-50-fs-Spektrometers zur Untersuchung der ultraschnellen molekularen Dynamik von Chlordioxid und Schwefelhexafluorid

    In dieser Arbeit werden die experimentellen Ergebnisse der ultraschnellen Anregung molekularer Strukturen präsentiert. Die zentrale Komponente besteht aus einem sub-50-fs-Spektrometer. Dabei handelt es sich um ein Ti:Saphir basiertes Verstärkersystem mit einer Energie von 2.5 mJ und einer Pulsdauer …

    fu-berlin Repository record for Entwicklung und Aufbau eines sub-50-fs-Spektrometers zur Untersuchung der ultraschnellen molekularen Dynamik von Chlordioxid und Schwefelhexafluorid (opens in a new tab)