Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 171 for “"home-built"”.
-
A Case Study of Zero Energy Home Built for Solar Decathlon Competition 2013
Energy consumption in residential homes has been a subject of research related to sustainability. Reduction in the consumption of energy is a goal of sustainable construction. The Department of Energy (DOE) started a Solar Decathlon competition in 2002 in which the students from different …
-
Improvement in dye sensitized solar cell efficiency through functionalization of redox mediators and passivation of the photoanode using a home-built atomic layer deposition system
The efficiency of dye sensitized solar cells (DSSCs) is driven based on the contributions of a vast array of kinetic and thermodynamic processes which must all function in sync with one another. The redox mediator factors into a majority of these processes and thus its proper function is vital to …
-
Usability of immersive virtual reality input devices
… a commercially available Intersense © Wand and a home built pinch glove and wireless receiver. Users were asked to carry out a series of minor tasks involving placement of shaped blocks into corresponding holes within an Immersive Virtual Reality Environment. Performance was evaluated in terms of …
-
X-ray lithographic fabrication of blazed diffraction gratings
… membrane X-Ray masks. The X-Ray apparatus is home built. In addition, the Ray Tracing algorithm is developed in order to simulate the resist etching process. The simulation results coincide exactly with the experimental ones.
-
STM in liquids. A scanning tunneling microscopy exploration of the liquid-solid interface.
… the liquid-solid interface, carried out with a home-built liquid-cell Scanning Tunnelling Microscope (STM). The home-built liquid-cell STM is described in detail, and numerical simulations are performed to show that surfaces immersed in the liquid-cell STM can be equally clean and well-defined …
-
Developing a Low-Frequency Raman Instrument for the Exploration of the Boson Peak in Amorphous Materials
… the capabilities and limitations of using a home-built Raman optical setup to access low-frequency domains in the glass former propylene carbonate with the goal of connecting the boson peak to fundamental particle modes of motion in inherent state motion and inter-basin crossings. Propylene …
-
Scanning probe microscopy investigation of bilayered manganites
… 0.32, 0.4 compounds at 80 K and 20 K by using a home-built low temperature scanning tunneling microscope (STM) and the evolution of the ferromagnetic domains with temperature and magnetic field in the x = 0.32 compound from 30 K to 110 K by using a home-built low temperature magnetic force …
-
Investigation of optical near field using near field scanning optical microscopy
… exit of a bowtie aperture is investigated with a home built aperture NSOM. The experiment results confirm the confinement of focused light spot and the fast decay nature of optical near fields. To further increase the transmission efficiency, a concentric grating structure is added to the bowtie …
-
Development of Modular High-Resolution Ion Mobility Orbitrap Platforms for Native Mass Spectrometry
… focuses on developing and implementing novel home-built instrumentation for native IM-MS to expand the capabilities of the biophysical toolbox in structural biology.
-
Applications of the Negatively-Charged Silicon Vacancy Color Center in Diamond
… and favorable photophysical properties. A home-built pulsed STED microscope was used to image shallow implanted SiV centers in bulk diamond at room temperature. We performed STED microscopy on isolated SiV centers and observed a lateral full-width-at-half-maximum spot size of 89 ± 2 nm, …
-
Magnetic studies of colossal magnetoresistance materials and FePt nanocrystals
… and describes the construction and design of a home built low temperature magnetic force microscope (MFM). Then the magnetic coatings on atomic force microscope cantilevers with a focused ion beam (FIB) will be explained. This technique allows the convenient deposition of complex or expensive …
-
High frequency microrheology with optical tweezers
… its one dimensional trajectory is obtained by a home-built split beam detection system, which works similar but responds faster than position detection with commercial quadrant photodiodes. The theory which is necessary to convert the particle trajectory into the complex shear modulus is derived …
-
Epitaxial graphene: synthesis, characterization, and devices
… by thermal annealing of the SiC substrates in a home-built customized UHV chamber that has been described in chapter3. The subsequent chapters report work related to photoconductive devices. A simple laser irradiation method has been developed to fabricate Schottky junction photodetectors on …
-
Characterization and First Results of an Inverse Photoemission Spectrometer
… thesis discusses our efforts to characterize our home built inverse photoemission spectrometer. We review the relevant theoretical and practical considerations for the technique of inverse photoemssion spectroscopy. We then detail our efforts to characterize our low energy electron gun, presenting …
-
Magneto-optical Kerr Eect Study of Magnetic Anisotropy in Soft Ferromagnets
… interface of Ni77Fe14Cu5Mo4/Fe50Mn50 bilayer. A home-built Magneto-optical Kerr effect magnetometer is used to measure the magnetic response of the soft ferromagnetic films and details of its construction are also discussed. A simple model of uniaxial anisotropy is described, then applied, to the …
-
AC magnetotransport, magnetocaloric and multiferroic studies in selected oxides
… normal and inverse MCEs is obtained from the home-built differential scanning calorimetry (DSC) and differential thermal analysis (DTA) techniques. Detailed magnetic and magnetoelectric studies on pure and cation doped Bi1-xAxFeO3 compounds revealed interesting properties. We discuss the …
-
Time resolved ultrafast dynamic excitations in semiconductors
… technique has been developed using a home- built and calibrated ellipsometer. The design and optimisation of the ellip- someter has been chosen carefully to study low absorption materials. The ellipsometric angles (Ψ and ∆) are measured in good agreement with commercial ellipsometry …
-
Characterization of Solid Lewis Acids in Biomass Conversion Reactions
… of solid Lewis acids were performed through home-built instruments including Temperature-Programmed Desorption (TPD)/Thermogravimetric Analysis (TGA), calorimetry, and a multiphase continuous flow reactor. A number of important catalyst families were examined in this work, including bulk …
-
Single-Molecule Super-Resolution Imaging of Geobacter sulfurreducens under Anaerobic Conditions
… localization microscope (SMLM) with a home-built anaerobic imaging chamber and use constant argon bubbling to maintain oxygen-free imaging conditions. To validate the imaging protocol, we use the transient binding of Nile red to resolve the spherical morphology of lipid-coated glass …
-
Place Not Of Place: The Moveable Home: A Critique of Suburbia
<p>Home is an architectural construct, one which historically is a product of a specific place. However, as place has become progressively more and more generic, architecturally, socially, communally, so too has the concept of home become more generic and at odds with the individual person. The …
Page 1 of 9