Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 19 of 19 for “"homogeneity index"”
-
A novel voxel based homogeneity index: rationale and clinical implications for whole-brain radiation therapy
A homogeneity index (HI) is an objective measure for the uniformity of a dose distribution within a given target volume in radiotherapy (RT). The calculation of conventional HIs is based on a limited number of dose volume histogram (DVH) data points which leads to assignment of the same score to RT …
-
An Algorithm to Determine IMRT Optimization Parameters within the Elekta Monaco® Treatment Planning System that Increases Dose Homogeneity and Dose Conformity in the Planning Target Volume
… treatment planning system that increases dose homogeneity and dose conformity in the planning target volume was developed. This algorithm determines IMRT optimization parameters by calculating the difference between two pairs of dose points along the target volume’s dose volume histogram: Dmax …
-
Improvements in 3D breast treatment plan quality and efficiency through computer automation of tangential breast radiotherapy treatment plans
… (FiF – or Field-in-Field), to increase the homogeneity of the radiation distribution. The protocol was tested on 10 CT datasets with five right side breast targets and five left side breast targets. Dose-volume statistics, dose distributions, and homogeneity index were calculated along with …
-
Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study
… parameters for PTV D50%, Dmax, Dmean, Conformity Index (CI), Homogeneity Index, Treated Volume (TV), Irradiated Volume (IV) and OAR constraints; femoral heads, bladder, bowel bag, rectum and bone marrow were collected. Results: Of the 45 patients assessed, VMAT showed significantly lower treatment …
-
INVESTIGATING TREATMENT PLANNING PARAMETERS FOR PROTON ARC TECHNIQUE IN PENCIL BEAM SCANNING (PBS) PROTON THERAPY
… evaluation included analysis of target coverage, homogeneity index (HI), and OARs sparing to determine an optimal parameter for clinical implementation.
-
RADIOBIOLOGICAL AND DOSIMETRIC COMPARISON OF IMRT AND SBRT FOR PROSTATE CANCER TREATMENT PLANNING
… with no significant difference observed in homogeneity index (HI). The maximum dose deviation from the prescribed dose remained within a 10% threshold for both plans. Although IMRT plans exhibited a higher conformity index compared to SBRT, SBRT plans with optimal conformity provided better …
-
Using Ordering Theory to Establish Student Knowledge Levels
… study, an active test with an acceptable CT3 homogeneity index was found. Two computer programs, RightOrder and MathTest, were written in Visual Basic. The latter administers the test, producing a file or responses that serves as input for the former, which performs the calculations and matrix …
-
Patient-specific intravascular brachytherapy dosimetry
… based on patient-specific materials and the dose homogeneity index, the ratio of the maximum and minimum target doses, were calculated.Results: Dose rate in water values using RapidBrachyIVBT agreed with TG-149 consensus dose rate values within 1.7%. The patient-specific absorbed dose in the test …
-
Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom
… to meet dose objectives, hot spots, conformity index, and homogeneity index. The planned treatments were delivered to the phantom and absolute doses and relative dose distributions were measured with thermoluminescent dosimeters (TLDs) and radiochromic film, respectively. The measured and …
-
Methods for determining lung function from tracer gas concentrations
… Capacity (FRC) or the ventilation-volume homogeneity of ventilated patients has been a long held goal. Such measures have the potential to greatly improve the treatment of patients by preventing ventilator related lung injuries. Many methods have been proposed, but none have seen routine …
-
Constrained marker-based VMAT plan optimization towards real-time tumour tracking
… using several metrics including the conformity index, homogeneity index, PTV average index and doses to organs-at-risk (OAR). Across all the disease sites, one marker is always fully visible at all BEV apertures (i.e. 100% of the gantry arc control points) for the constrained plans. All three …
-
Συγκριτική μελέτη διαφόρων τεχνικών ακτινοθεραπείας για την ακτινοβόληση ευμεγεθών αριστερών μαστών
… στους υγιείς ιστούς, το δείκτη ομοιογένειας (Homogeneity Index), το δείκτη συμμόρφωσης (Conformity Index), το βαθμό διαμόρφωσης (modulation degree) και τα Monitor Units του κάθε πλάνου θεραπείας. Η τεχνική Sliding Window - IMRT επιτυγχάνει καλύτερη κάλυψη για περιστατικά ευμεγεθών αριστερών …
-
Measurement of heterogeneity in low consistency pulp refining by comminution modeling
… impacts. The findings showed, for example, that homogeneity of treatment is more dependent on numbers of impacts than on uniformity of intensity during impacts. A single number “homogeneity index” was proposed and defined as the product of the number of impacts on fibres having length-weighted …
-
Optimization algorithm of a high dose-rate brachytherapy treatment plan for cervical cancer patients in Zambia.
… criteria. While values for the Conformity Index (COIN), Conformity Number (CN), and Coverage Index (CI) were better in 2019 compared with other years; Dose Non-Uniformity Ratio (DNR) and Dose Homogeneity Index (DHI) remained low throughout all years reviewed. Nonetheless, most analyzed …
-
Characterization Of A Miniature X-Ray Source And Evaluation Of The Clinical Implications For Intraoperative Breast Radiotherapy
… cavity using V90, V80, V50, Dmin, D0.1, and homogeneity index (HI) dose-volume parameters and to assess the change in R80 and R90 therapeutic treatment depths (TTDs) because of spherical applicator size and filter design. For spherical applicator diameters 1.5- to 5.0-cm, DVPs ranged from: …
-
Comparación de las técnicas dinámica y estática para la administración de la dosis en Radioterapia de Intensidad Modulada (IMRT)
… using the following parameters: conformation index, homogeneity index, average dose and the dose given to the fraction x of the total volume of organs at risk. Activities will include a study of fluence maps to verify the Eclipse planning system to model both modes of delivery. Dosimetric …
-
Realistic Respiratory Motion and its Impact on Partial Breast Intensity Modulated Radiotherapy Treatment Planning
… motion from 2 - 20 mm. We found that dose homogeneity, namely hotspot and homogeneity index, were the limiting factor in plan quality and not target coverage. We recommend respiratory management for patients with respiratory amplitude greater than 10 mm. Due to the propensity of hotspots …
-
A Homogeneity-based Zone Delineation Model for Land Use and Transportation Interaction Analysis: Investigating the Case of Light Rail Transit (LRT) Development in Kitchener – Waterloo
… not necessarily provide satisfactory levels of homogeneity due primarily to the insufficiency of density as the primary measure to create these zones and the arbitrary use of roadways in breaking the zones boundaries. As we move towards an era in which new mobility modes emerge and modern data …
-
Modeling of gene and protein networks in the context of plant immunity
… algorithms and ensembled based on the Biological Homogeneity Index (BHI) of the communities of the network. The resulting GRN covered 76% of the barley genome, including 1214 TFs, 20125 targets, and 54698 interactions. Hypergeometric tests were performed looking for enrichment of differentially …