HVAC Economizer Redesign
An economizer is a HVAC (Heating, Ventilation, and Air Conditioning) appliance designed to regulate the intake and outtake of ambient air of HVAC devices, such as building air conditioners. This design project was conducted in collaboration with MicroMetl Corporation, a local sheet metal company …
-
Decentralized HVAC Operations: Novel Sensing Technologies and Control for Human-Aware HVAC Operations
… Heating, Ventilation, and Air-Conditioning (HVAC) HVAC operations. It has been envisioned that development of personal thermal comfort profiles leads to accurate predictions of each occupant's thermal comfort state and such information is employed in context-aware HVAC operations for energy …
-
Ozone interactions with HVAC filters
… to investigate ozone interactions with HVAC filters. Experimental results indicate that activated carbon filters can effectively remove ozone, used commercial HVAC filters remove more ozone than used residential HVAC filters, and for most filters the ozone removal efficiency declined …
-
Directional Airflow for HVAC Systems
… of flow. In the building sector however, HVAC systems are usually equipped with stationary diffusors that can only supply the air either in the form of diffusion or with fixed direction to the room in which they have been installed. In the present thesis, the possibility of adopting …
-
Distributed Control of HVAC&R Networks
… air conditioning, and refrigeration (HVAC&R) systems are a major component of worldwide energy consumption, and frequently consist of complex networks of interconnected components. The ubiquitous nature of these systems suggests that improvements in their energy efficiency …
-
Dräneringslösning till HVAC-modul för fordon
… goal was to develop a drainage solution for an HVAC-module applied within automotive and this solution should be able to fit four different types of vehicles. The solution should lead the condensed water from the HVAC outlet through the chassis. A tube should then be mounted on bottom of the …
-
Dynamic Control of HVAC Attributes. Improving Energy Efficiency of HVAC System Using Machine Learning and Computational Fluid Dynamics
Heating, Ventilation and Air-Conditioning (HVAC) accounts for a major share of building energy use. This thesis develops a data-driven HVAC control framework that couples high-fidelity Computational Fluid Dynamics (CFD) with machine learning. Three-dimensional CFD simulation is performed to model …
-
Impact of Climate Change on High-Performance Belgian Houses: Thermal Comfort, HVAC Energy Performance, and HVAC GHG Emissions
… the changes in thermal comfort conditions, HVAC energy performance, and HVAC Greenhouse Gas (GHG) emissions in Belgian high-performance houses due to climate change. This part includes the evaluation of a set of active and passive cooling strategies based on uncertainty analysis, sensitivity …
-
HVAC control using support vector regression models
… control of temperature and relative humidity. HVAC system is a typical nonlinear system. Support vector regression (SVR) is a type of model that is optimized so that prediction error and model complexity are simultaneously minimized. In this project, support vector regression is used to build …
-
Cascaded Control for Improved Building HVAC Performance
… systems. Focusing on improving building HVAC control therefore has a large aggregate effect on US energy usage with economic and environmental benefits for end users. This dissertation develops cascaded loop architectures as a solution to common HVAC control issues. These systems display …
-
MODEL PREDICTIVE CONTROL OF BUILDING HVAC SYSTEMS
… Model uncertainty is unavoidable for building HVAC systems. In this PhD proposal, the impact of model uncertainty is characterized on model-based controllers, e.g. model predictive control (MPC), and robust model predictive control (RMPC). Closed-loop RMPC uses uncertainty knowledge to enhance …
-
Measure Whole-Building HVAC System Energy Efficiency
… that are considered with respect to building HVAC systems efficiency. However, during operation, several other components consume energy as part of the HVAC system, such as pumps and fans. If a complete building HVAC system efficiency measure would like to be identified, it is necessary to …
-
HVAC operation uncertainty in energy performance gap
This study aims at a preliminary characterization of system operation uncertainty. It bases this on an analysis of the energy consumption of 6 existing buildings on the Georgia Tech campus. The analysis is speculative in nature.
-
Energioptimering av HVAC-system i större passagerarfartyg
HVAC ( Heating, Ventilation, Air Condition) play an important role in passenger ferries and cruise ships, where indoor air quality and temperature need to be controlled for the comfort of passengers as well as crew. As HVAC-systems are designed to deliver large air volumes, often at significant …
-
Noise Sources Characterization of Automotive HVAC Systems
… sources and mechanisms of the front and rear HVAC systems of an automotive are characterized experimentally. The front system has three main outlet ducts equipped with louvers and operates in two modes of bypass and recirculation. The inlet and outlet sides of the rear system are both located …
-
Integrated device control for residential HVAC load reduction
… maybe possible without replacing the existing HVAC unit. This study developed an integrated control software, iDECK, and simulated its performance based on weather data in Austin, Texas. However, the results showed minimal energy benefit, indicating the selected alternative cooling methods were …
-
Design of HVAC duct stiffeners with tie rods
<p>"HVAC" ducts are made of thin gauge sheet metal. They are usually reinforced with transverse stiffeners. These stiffeners are usually made of hot rolled steel sections, such as equal leg angles or channels.</p><p>When the size of an "HVAC" duct exceeds 72 inches, additional stiffeners in the …
-
On circular HVAC duct design through stress analysis
… studies through stress analysis of the circular HVAC ducts are made. The ducts are made of thin gaged steel sheet, and reinforced by stiffeners that are made of hot-rolled steel sections of L or C shapes. The ducts are loaded with pressure, its own weight and the possible seismic accelerations. A …
-
On natural frequency of the stiffened HVAC ducts
… calculate the natural frequency of a stiffened HVAC duct and to investigate the affect of these stiffeners to the values of the natural frequency.</p><p>Investigation through this thesis shows that increases in the number of transverse stiffeners mould increase the natural frequency of the HVAC …
Page 1 of 63