  1. The Influence of Hydraulic Loading Rate on Nitrification Performance in a Two-Stage Biological Aerated Filter Pilot Plant

    … one, ammonia oxidation stage two) biological aerated filter was operated for 10 months on-site at a domestic wastewater treatment plant. Over the study, the system was operated at different hydraulic loading rates that resulted in a range of applied organic and ammonia mass loadings. Performance …

    vt Repository record for The Influence of Hydraulic Loading Rate on Nitrification Performance in a Two-Stage Biological Aerated Filter Pilot Plant (opens in a new tab)

  2. Tertiary treatment of wastewater using multimedia filtration for solids removal

    … A pilot-scale quadruple media filter was operated at the Cranfield Sewage Works to investigate the removal of suspended solids from secondary treated wastewater effluent under controlled and variable hydraulic loading rate, solids concentration and different wastewater characteristics. To …

    cranfield Repository record for Tertiary treatment of wastewater using multimedia filtration for solids removal (opens in a new tab)

  3. Removing algae from stabilization pond effluents by using trickling filters

    … the effect of individual operational parameters (hydraulic loading rate, influent COD and chlorophyll-a concentration) and of their combinations on organics and particle removal efficacy an experimental design was followed. Experiments consistent with twolevel factorial design with three variables …

    metu Repository record for Removing algae from stabilization pond effluents by using trickling filters (opens in a new tab)

  4. Development of a Passive Filter for Polishing Municipal Lagoon Effluent-Lab and Field Scale Studies

    … include identifying the best media type and hydraulic loading rate for an unsaturated filter, evaluating the hydraulic retention time (HRT) and adsorptive capacity for a saturated filter, and pilot-scale testing of the technology. The experimental variables include unsaturated media, filter …

    ottawa-retro Repository record for Development of a Passive Filter for Polishing Municipal Lagoon Effluent-Lab and Field Scale Studies (opens in a new tab)

  5. Nitrification of Landfill Leachate by Biofilm Columns

    … and the age of the landfill. At landfills operated as bioreactors, where leachate recirculation is practiced, leachate ammonia nitrogen concentrations may accumulate to extremely higher levels than during single pass leaching, thereby requiring treatment before final discharge to a receiving …

    vt Repository record for Nitrification of Landfill Leachate by Biofilm Columns (opens in a new tab)

  6. Development of a Combined Reed Bed – Freezing Bed Technology to Treat Septage in Cold Climates

    … Pilot studies showed that freezing beds can operate without the need for a cover with the applied sludge effectively melting any snow cover in regions with moderate snowfall. Septage freezing was successfully modelled following an accepted model for ice formation on water bodies while septage …

    ottawa-retro Repository record for Development of a Combined Reed Bed – Freezing Bed Technology to Treat Septage in Cold Climates (opens in a new tab)

  7. Anaerobic Treatment of Whey Permeate Using Upflow Sludge Blanket Bioreactors

    … upflow anaerobic sludge blanket reactors. Nine hydraulic retention times between 5 and 0.2 days were examined with a fixed influent concentration of 10.6 ± 0.2 g COD/L. Chemical oxygen demand removal efficiency ranged from 99.0 to 18.9% and maximum production rate of methane gas was 2.67 L/L/day …

    utahstate Repository record for Anaerobic Treatment of Whey Permeate Using Upflow Sludge Blanket Bioreactors (opens in a new tab)

  8. A laboratory study of factors affecting the applicability of direct filtration water treatment

    … of flocculation with direct filtration, and the hydraulic loading rate applied to the filter. Results indicated that direct filtration treatment may be an attractive treatment alternative for raw water of influent turbidity less than 5-8 Ntu. Alum appeared to be the coagulant of choice because …

    vt Repository record for A laboratory study of factors affecting the applicability of direct filtration water treatment (opens in a new tab)

  9. High-Rate Infiltration-Percolation Treatment of Wastewater to Satisfy Effluent Requirements

    … compare effects of the type of basin surface and hydraulic loading rate on the quality of the renovated water. Other areas of the EPA project included: determination of the hydraulic loading rates acceptable to the soil, determination of the nitrogen and phosphorous removal accomplished within the …

    sdstate Repository record for High-Rate Infiltration-Percolation Treatment of Wastewater to Satisfy Effluent Requirements (opens in a new tab)

  10. Thiosulfate oxidation in a fluidized bed

    … autotrophic fluidized bed was continuously operated using a synthetic thiosulfate waste. The reactor was maintained at a hydraulic loading rate of 16.1 gpm/ft² and an influent thiosulfate concentration of 100 mg/1. The void space detention time at this loading rate was approximately 0.6 …

    vt Repository record for Thiosulfate oxidation in a fluidized bed (opens in a new tab)

  11. Innovating Green Stormwater Infrastructure for Nutrient Management: Long-Term Field and Modeling Studies of Conventional and Modified Denitrifying Bioretention Systems

    … best management practices that can be applied strategically throughout a watershed to capture stormwater and reduce pollutants from urban runoff to natural waterways. One such technology increasingly being implemented is bioretention, a structural low impact development technology. Bioretention …

    usf Repository record for Innovating Green Stormwater Infrastructure for Nutrient Management: Long-Term Field and Modeling Studies of Conventional and Modified Denitrifying Bioretention Systems (opens in a new tab)

  12. Evaluating the use of manganese-oxidizing bacteria in surface water treatment plants

    … to optimize organics removal has not been demonstrated. Laboratory-scale biofilters were operated to evaluate the ability of MOB to accomplish soluble Mn control at a range of pH (6.3--7.3). The biofilters were able to oxidize Mn at a pH as low as 6.3 at greater than 98% removal. Ozonation …

    vt Repository record for Evaluating the use of manganese-oxidizing bacteria in surface water treatment plants (opens in a new tab)

  13. Hydraulic characteristics of feedlot manure in an anaerobic leachate bed reactor

    Concentrated animal feeding operations (CAFOs) use the practice of optimizing space for the raising of livestock. By implementing space-saving techniques, these operations end up with large quantities of waste on small parcels of land. One way to utilize the waste is to integrate an anaerobic …

    colostate Repository record for Hydraulic characteristics of feedlot manure in an anaerobic leachate bed reactor (opens in a new tab)

  14. Sustainable Drinking Water Treatment for Small Communities Using Multistage Slow Sand Filtration

    … testing of its performance under increased hydraulic loadings and elevated influent turbidity together with cold water conditions. The primary goal of this research was to demonstrate the reliability of multistage filtration for small communities in northern climates with reference to the …

    waterloo Repository record for Sustainable Drinking Water Treatment for Small Communities Using Multistage Slow Sand Filtration (opens in a new tab)

  15. Domestic wastewater treatment in pilot-scale constructed wetlands implemented in the Middle East Technical University

    … and gravel-filled vertical flow wetlands were operated identically with pre-settled domestic wastewater (3 m3.d-1) at a hydraulic loading rate of 110 mm.d-1 for 12 months, intermittently. According to the first year results, annual average removal efficiencies for the slag and gravel wetland cells …

    metu Repository record for Domestic wastewater treatment in pilot-scale constructed wetlands implemented in the Middle East Technical University (opens in a new tab)

  16. Development of Soluble Manganese Sorptive Contactors for Enhancing Potable Water Treatment Practices

    … via adsorption onto larger media (2.0-6.4mm) at hydraulic loading rates of 16-24 gpm/ft², thus producing less head loss and furthering the development of soluble Mn sorptive contactors to be implemented in water treatment facilities. Research was conducted by executing laboratory- and pilot-scale …

    vt Repository record for Development of Soluble Manganese Sorptive Contactors for Enhancing Potable Water Treatment Practices (opens in a new tab)

  17. Low-head, roughing filters for enhancing recycle water treatment for aquaculture

    … the pilot plant permitted the use of a range of hydraulic and solid loading rates to evaluate these clarification processes. Nitrification was evaluated using submerged, static-media, biological filters over a range of hydraulic and ammonia loading rates. Acceptable levels of oxygen and carbon …

    iastate Repository record for Low-head, roughing filters for enhancing recycle water treatment for aquaculture (opens in a new tab)

Page 1 of 3