Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"hydrodynamic device"”.

  1. Investigation of DC, microwave characteristics and noise in SiGe and A3B5 heterojunction bipolar transistors /

    … for SiGe HBTs. Modeling was performed with a hydrodynamic model, drift - diffusion models and the compact model HICUM using a Chynoweth’s law for avalanche generation. DC, high frequency characteristics and noise of SiGe HBTs were investigated in a wide ambient temperature range 4 – 423 K Both …

    vilnius Repository record for Investigation of DC, microwave characteristics and noise in SiGe and A3B5 heterojunction bipolar transistors / (opens in a new tab)

  2. Aukštadažnių SiGe ir A3B5 įvairialyčių dvipolių tranzistorių statinių, mikrobangių charakteristikų ir triukšmo tyrimas /

    … for SiGe HBTs. Modeling was performed with a hydrodynamic model, drift - diffusion models and the compact model HICUM using a Chynoweth’s law for avalanche generation. DC, high frequency characteristics and noise of SiGe HBTs were investigated in a wide ambient temperature range 4 – 423 K Both …

    vilnius Repository record for Aukštadažnių SiGe ir A3B5 įvairialyčių dvipolių tranzistorių statinių, mikrobangių charakteristikų ir triukšmo tyrimas / (opens in a new tab)

  3. Numerical simulation of sub-100 nm strained Si/SiGe MOSFETs for RF and CMOS applications

    Drift-Diffusion, Hydrodynamic and Monte Carlo simulations have been used in this work to simulate strained Si/SiGe devices for RF and CMOS applications. For numerical simulations of Si/SiGe devices, strain effects on the band structure of Si have been analyzed and analytical expressions are …

    glasgow Download PDF for Numerical simulation of sub-100 nm strained Si/SiGe MOSFETs for RF and CMOS applications (opens in a new tab)

  4. BMP Efficiency in an Institutional Area: Minimizing the Impacts of Water Pollution Using a Stormceptor for Water Quality Improvement

    … runoff by implementing BMPs. BSC installed a hydrodynamic separator system (In - Line Stormceptor STC - 2400 ®Stormceptor) manufactured by Rinker to reduce stormwater pollution. It is designed to remove sediment particles from stormwater runoff and as well as variety of pollutants by means of …

    buff-state Repository record for BMP Efficiency in an Institutional Area: Minimizing the Impacts of Water Pollution Using a Stormceptor for Water Quality Improvement (opens in a new tab)

  5. Design and Development of a Real-time Monitoring Microfluidic Platform for Multiplexed Biomarker Detection

    … models showed successful cross-validation of the device with the gold-standard ELISA. In the next step, the QIRT-ELISA was expanded for more complex system measurements. The expanded QIRT-ELISA can monitor four biomarkers continuously in a multiplexed setting. To bridge the gap in diabetes …

    waterloo Repository record for Design and Development of a Real-time Monitoring Microfluidic Platform for Multiplexed Biomarker Detection (opens in a new tab)