Results
Showing 1 to 20 of 231 for “"hygrothermal"”.
-
Hygrothermal Behavior of Interior Basement Insulation
… experimental and analytical investigation of the hygrothermal behavior of interior insulated basement walls. The experimental portion involved the hygrothermal monitoring of twelve interior basement insulation assemblies in two field locations (Huntley, IL, and Kitchener, ON). The measured …
-
Hygrothermal Performance of Residential Cantilevered Floors
… more comprehensive representation of the annual hygrothermal cycle.
-
The Hygrothermal Performance of Exterior Insulated Wall Systems
… Waterloo’s BEGHUT test facility to evaluate the hygrothermal performance of exterior insulated wall systems utilizing 3 different insulation types. These walls had approximately 2/3 of their total thermal resistance interior to the sheathing and 1/3 exterior to the sheathing. These walls were …
-
Experimental study of hygrothermal properties for building materials
In this thesis, the hygrothermal properties of building materials are studied experimentally and numerically. The properties of 10 building materials which are widely used in Canada were determined using either international standard or well-documented and peer-reviewed approaches. The measured …
-
Hygrothermal Performance of Insulated, Sloped, Wood-Framed Roof Assemblies
… by all cultures in all climate regions. The hygrothermal performance of insulated, sloped, wood-framed roof assemblies has long been of interest to building scientists and building codes alike. Requirements for the ventilation of roof assemblies have been included in building codes for more …
-
Hygrothermal Effects on Viscoelastic Properties of Amine-Hardened Epoxy
… has been characterized after exposure to hygrothermal conditions for up to 2400 hours. The objectives of the study were to determine the diffusion coefficient, the viscoelastic and glass transition temperature changes as result of long-term aging. Due to the large number of samples …
-
Evaluating Uncertainty in Hygrothermal Modelling of Heritage Masonry Buildings
Hygrothermal models are important tools for assessing durability risks in building envelopes, such as biological growth (mould and wood rot fungi), corrosion and freeze-thaw action in masonry. Hygrothermal modelling of mass masonry wall assemblies are known to have numerous weaknesses and gaps in …
-
MECHANICAL AND TRANSIENT HYGROTHERMAL LOADING OF MULTILAYER ORTHOTROPIC CYLINDERS
… under static mechanical loading and transient hygrothermal loading has been developed. Stresses, strains, and radial displacements are calculated under loading conditions of internal and external pressure, axial load or axial strain, rotation, and temperature and moisture profiles which are …
-
Hygrothermal effects of epoxy resins and graphite/epoxy composites
Thesis (Ph. D.)--Michigan State University. Dept. of Materials Science and Mechanics, 1996
-
Modelling the hygrothermal behaviour of crop-based construction materials
… It is understandable why modelling their hygrothermal behaviour and evaluating the impact on indoor air volumes is essential during the design phases. This thesis explores themodelling of the hygrothermal behaviour of crop-basedmaterials with a numerical tool. The latter is developed in a …
-
Hygrothermal Effects of Air Cavities Behind Claddings on Building Envelopes
… assumed to simplify the investigation of the hygrothermal performance of a cladding system. Moreover, the literature lacks a study of the effect of humid air in the air cavity on heat and mass transfer. Therefore, it necessitates advanced problem formulation and solving to comprehensively …
-
Hygrothermal resiliency of wood-frame wall assemblies and climate change
… conditions driven by climate change. Existing hygrothermal performance metrics do not adequately capture the resilience of building envelopes to prolonged and extreme moisture loading. This thesis presents a comprehensive hygrothermal analysis of the resilience of wood-frame building envelopes …
-
Hygrothermal effects on free vibration characteristics of rotating composite beams
… composite cantilever beams subjected to a hygrothermal environment is studied using the finite element analysis. The problem is formulated using a First Order Shear Deformation theory (FSDT) for composite materials. The finite element formulation is based on variational principles and the …
-
Hygrothermal performance of hempcrete infill wall systems in cold climates
… with heat flow meter Fox314, whereas the hygrothermal analysis of wall assemblies was performed using WUFI soft-ware. The densities of hempcrete samples produced in this study show excellent con-sistency, ranging from 298.55 kg/m3 to 318.05 kg/m3, with the average density of all sam-ples …
-
Hygrothermal modeling and testing of polymers and polymer matrix composites
… on polymers and polymer matrix composites. Hygrothermal models were developed that would allow characterization of non-Fickian diffusion coefficients from moisture weight gain data. Hygrothermal testing was also conducted to provide the necessary data for characterizing of model coefficients …
-
Thermo-oxidation and hygrothermal effects on cyanate ester polymer materials
Thesis (M.S.)--Michigan State University. Department of Materials Science and Mechanics, 1999
-
Hygrothermal Analysis and Failure Analysis of Composite Beams under Moving Loads
… Thus, in this study, the effect of hygrothermal conditions on fiber reinforced composite laminates with moving loads have been extensively studied and has been carried out that accompanies Classical Laminate Plate Theory (CLPT) as well as First Order Shear Deformation Theory (FSDT) …
-
Bond Life of Structural Epoxy-Concrete Systems Under Accelerated Hygrothermal Aging
… into bond degradation behavior under accelerated hygrothermal conditions, present a means for conducting controlled rate bond testing, and offer a quick and robust method for determining the onset of bond life in epoxy-concrete systems without the need for complex analyses or additional …