Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 32 for “"hyperpolarized 129xe"”.

  1. Preclinical Hyperpolarized 129Xe MRI: Development, Applications, and Dissemination

    <p>Hyperpolarized (HP) gas MRI is emerging as a powerful, non-invasive method for imaging lung function. MRI of HP 129Xe and 3He was first introduced in small animals and was soon followed by its clinical implementation. 3He was preferred for imaging since it was more straight-forward to …

    duke Repository record for Preclinical Hyperpolarized 129Xe MRI: Development, Applications, and Dissemination (opens in a new tab)

  2. Quantitative Spectral Contrast in Hyperpolarized 129Xe Pulmonary MRI

    <p>Hyperpolarized (HP) 129Xe MRI has emerged as a viable tool for evaluating lung function without ionizing radiation. HP 129Xe has already been used to image ventilation and quantify ventilation defects. However, this thesis aims to further develop imaging techniques that are capable of imaging, …

    duke Repository record for Quantitative Spectral Contrast in Hyperpolarized 129Xe Pulmonary MRI (opens in a new tab)

  3. Improved Visualization and Quantification for Hyperpolarized 129Xe MRI

    … </p><p> In recent years, the introduction of hyperpolarized (HP) 129Xe magnetic resonance imaging (MRI) into clinical research has provided a robust and non-invasive 3D imaging technique, capable of both high-resolution imaging of pulmonary ventilation and gas exchange. Notably, gas exchange …

    duke Repository record for Improved Visualization and Quantification for Hyperpolarized 129Xe MRI (opens in a new tab)

  4. Quantitative Hyperpolarized 129Xe Gas exchange MRI: Development and Applications

    … gap has been addressed by the application of hyperpolarized (HP) 129Xe magnetic resonance imaging (MRI). HP 129Xe ventilation imaging generates 3D images of 129Xe distributed in the lungs to probe ventilation function and reveal regional ventilation defect. It has been applied in clinical …

    duke Repository record for Quantitative Hyperpolarized 129Xe Gas exchange MRI: Development and Applications (opens in a new tab)

  5. Hyperpolarized 129Xe Diffusion-weighted MRI for Lung Morphometry of Bronchopulmonary Dysplasia

    … sections and fields. With the advent of hyperpolarized (HP) gas magnetic resonance (MR) imaging, non-invasive imaging of terminal airway structure and function is achievable in vivo. HP 129Xe MR morphometric imaging exploits diffusion weighting along with a theoretical cylinder model of …

    toronto-retro Repository record for Hyperpolarized 129Xe Diffusion-weighted MRI for Lung Morphometry of Bronchopulmonary Dysplasia (opens in a new tab)

  6. Dissolved Hyperpolarized 129Xe MRI for Functional Imaging of Radiation-Induced Lung Injury

    Hyperpolarized (HP) 129Xe Magnetic Resonance Imaging (MRI) of the lungs allows for the visualization of the spatial distribution of gas in the pulmonary airspaces upon inhalation by taking advantage of the 100,000 fold increase in signal. This technique yields high quality anatomical and functional …

    toronto-retro Repository record for Dissolved Hyperpolarized 129Xe MRI for Functional Imaging of Radiation-Induced Lung Injury (opens in a new tab)

  7. Translational Imaging of Pulmonary Gas-Exchange Using Hyperpolarized 129Xe Magnetic Resonance Imaging

    … by taking advantage of the unique properties of hyperpolarized (HP) <super>129</super>Xe in conjunction with magnetic resonance imaging (MRI), to probe the fundamental function of the lung - gas-exchange. </p><p>While a bulk of the inhaled HP <super>129</super>Xe stays in the alveolar spaces, its …

    duke Repository record for Translational Imaging of Pulmonary Gas-Exchange Using Hyperpolarized 129Xe Magnetic Resonance Imaging (opens in a new tab)

  8. Towards Comprehensive Mapping of Lung Function Using Hyperpolarized 129Xe MRI: Developments and Applications

    <p>Hyperpolarized 129Xe magnetic resonance imaging (MRI) and spectroscopy (MRS) have emerged as a set of effective tools for evaluating pulmonary function, offering unique insights into ventilation, gas exchange, and cardiopulmonary dynamics without exposing patients to ionizing radiation. This …

    duke Repository record for Towards Comprehensive Mapping of Lung Function Using Hyperpolarized 129Xe MRI: Developments and Applications (opens in a new tab)

  9. Hyperpolarized 129Xe Magnetic Resonance Spectroscopy and Imaging of Blood Oxygenation and Gas Exchange in Rats

    Hyperpolarized 129Xe gas is a safe, non-reactive contrast agent for MRI. Once inhaled, 129Xe dissolves through the lung parenchyma and into the pulmonary blood. The 129Xe is then transported to peripheral organs such as the brain via the vascular system and, when in the brain, 129Xe freely …

    toronto-retro Repository record for Hyperpolarized 129Xe Magnetic Resonance Spectroscopy and Imaging of Blood Oxygenation and Gas Exchange in Rats (opens in a new tab)

  10. Applications of Hyperpolarized Xenon-129 Nmr and Chemical Exchange Saturation Transfer in Biosensing

    … solution to both problems is the combination of hyperpolarized 129Xe MRI with biosensors, which offers significant sensitivity enhancement at a much lower cost. This dissertation reports my progress in hyperpolarized 129Xe nuclear magnetic resonance (NMR) studies for use in future …

    penn Repository record for Applications of Hyperpolarized Xenon-129 Nmr and Chemical Exchange Saturation Transfer in Biosensing (opens in a new tab)

  11. New Biosensing Strategies Using Hyperpolarized Xenon-129 Nmr Spectroscopy

    … proton densities. To address these limitations, hyperpolarized 129Xe NMR spectroscopy and MRI have emerged as attractive complementary methodologies. Beyond hyperpolarization, a 107-fold signal enhancement can be achieved by using novel indirect detection schemes (namely, Hyper-CEST), showing …

    penn Repository record for New Biosensing Strategies Using Hyperpolarized Xenon-129 Nmr Spectroscopy (opens in a new tab)

  12. Cryptophane Derivatives as Gas Sensors and Hyperpolarized Xenon-129 Biosensors

    … CRYPTOPHANE DERIVATIVES AS GAS SENSORS AND HYPERPOLARIZED XENON-129 BIOSENSORS Najat S. Khan Professor Ivan J. Dmochowski This thesis describes the progress in the development of cryptophanes for three different applications: encapsulation of noble gases, 129Xe NMR biosensing for cancer …

    penn Repository record for Cryptophane Derivatives as Gas Sensors and Hyperpolarized Xenon-129 Biosensors (opens in a new tab)

  13. Radio Frequency Coil and Pulse Sequence Design for Hyperpolarised Noble Gas MRI of the Human Lungs and Brain

    … that can be imaged. Hyperpolarised gas (3He and 129Xe) MRI provides solutions to these challenges by imaging the ventilated airspaces and provides clinical sensitivity to lung disease pathophysiology such as ventilation defects, obstructive lung disease, emphysematous alveolar damage, …

    whiterose Download file for Radio Frequency Coil and Pulse Sequence Design for Hyperpolarised Noble Gas MRI of the Human Lungs and Brain (opens in a new tab)

Page 1 of 2