Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"hysteresis control"”.

  1. Hysteresis control of parallel-connected hybrid inverters

    … These systems will allow unprecedented control of shipboard power to propel the ship, sense the battle-space, and engage the enemy. One crucial enabling technology is robust power conversion modules like the hybrid dc to ac inverter. This thesis is a further exploration of the hybrid …

    nps Repository record for Hysteresis control of parallel-connected hybrid inverters (opens in a new tab)

  2. A Nine-Switch UPQC with Variable-Band Hysteresis Control

    … and cost of the entire system. A variable-band hysteresis control method that is applied to the shunt and series terminals performs independent control of the nine-switch UPQC currents and voltages. The shunt and series terminal controllers are accurate and fully utilize the nine-switch UPQC …

    queens Repository record for A Nine-Switch UPQC with Variable-Band Hysteresis Control (opens in a new tab)

  3. Field programmable gate array hysteresis control of parallel connected inverters

    … use of a Field Programmable Gate Array (FPGA) to control two Commercial-Off-The-Shelf (COTS) Power Electronic Building Blocks (PEBB) configured to produce a three-phase low distortion sine wave output. The next generation warship is expected to contain more electric loads that require quality …

    nps Repository record for Field programmable gate array hysteresis control of parallel connected inverters (opens in a new tab)

  4. A three-phase hybrid dc-ac inverter system utilizing hysteresis control

    … a hybrid dc-ac power converter that combines a hysteresis controlled inverter with a six-step bulk inverter. A six-step bulk inverter is built from discrete components and tested in simulation and hardware. The two inverters are connected in parallel to provide a high-fidelity current source for …

    nps Repository record for A three-phase hybrid dc-ac inverter system utilizing hysteresis control (opens in a new tab)

  5. Controlled on-time power factor correction circuit with input filter

    An active power factor correction circuit with controlled on-time is proposed. The circuit has a simpler control scheme than the power bc10r correction circuit with hysteresis control, and yet is able to attain high power factor. A very important aspect of this work was the formulation of the …

    vt Repository record for Controlled on-time power factor correction circuit with input filter (opens in a new tab)

  6. Design and analysis of an active power factor correction circuit

    … power factor correction circuit with variable-hysteresis control for off-line dc-to-dc switching power supplies is described. Design equations relating the boost inductor current ripple to the circuit components selection and circuit performance arc discussed. A computer-aided design program …

    vt Repository record for Design and analysis of an active power factor correction circuit (opens in a new tab)

  7. An Analysis and Improvement of Brushless DC Motor Control System

    … electromagnetic sensors are used. In sensorless control, rotor back EMF detection is the most popular technique for speed and position control. Detection of back EMF by novel speed independent commutation function is a very well researched topic that has overcome most of the problems of …

    ndsu Repository record for An Analysis and Improvement of Brushless DC Motor Control System (opens in a new tab)

  8. Single Inductor Dual Output Buck Converter

    … desired values (1.2V,1.5V) within well controlled ripple levels. Dynamic hysteresis control is used for the single inductor dual output buck converter in this work. Results of schematic and post layout simulations performed in CADENCE prove the merits of this control method, such as nil …

    tamu Repository record for Single Inductor Dual Output Buck Converter (opens in a new tab)

  9. Multi-Phase Fault Tolerant PMSM Drive Systems

    … a fault condition, simple but effective current control methods are necessary. An interior PMSM configuration with 5 independent phases is presented for electric vehicle (EV) traction and ship propulsion applications along with the proposed design procedure as well as an associated inverter …

    tamu Repository record for Multi-Phase Fault Tolerant PMSM Drive Systems (opens in a new tab)

  10. A phase shedding technique for PV system based on interleaved boost converter

    … boost converter. Moreover, a new phase shedding control method of an interleaved boost converter as PV pre-regulator is proposed as a way to improve the efficiency of the converter at light load condition. The efficiency improvement of the interleaved boost converter and the minimization of …

    unsw Repository record for A phase shedding technique for PV system based on interleaved boost converter (opens in a new tab)

  11. Study of a High-Efficient Wide-Bandgap DC-DC Power Converter for Solar Power Integration

    … radiation, a novel sliding-window-combined (SWC) hysteresis control technique was proposed and preliminarily verified by a simulation study to enhance transients of a power grid.

    odu Repository record for Study of a High-Efficient Wide-Bandgap DC-DC Power Converter for Solar Power Integration (opens in a new tab)

  12. Design and implementation of a CMOS hybrid envelope tracking supply modulator utilizing a class-B linear amplifier for 5G new radio applications

    … range above the typical battery level. A simple hysteresis control loop is used to regulate the converter, which automatically adjusts the slew rate of the SA current when high output power is required. Additionally, a micro boost converter is implemented to efficiently raise the supply voltage …

    texas Repository record for Design and implementation of a CMOS hybrid envelope tracking supply modulator utilizing a class-B linear amplifier for 5G new radio applications (opens in a new tab)

  13. Active Balancing to Improve the Efficiency and Sustainability of Battery Management Systems

    … can balance multiple cells simultaneously with a controllable current that is independent of the imbalance level. Experimental tests on a five-cell lithium-ion battery pack demonstrate that the design is effective under both charging and discharging conditions. The second work proposes a …

    unsw Repository record for Active Balancing to Improve the Efficiency and Sustainability of Battery Management Systems (opens in a new tab) Embargoed

  14. Dynamometer Testing and Characterization of Switched Reluctance Motors (SRMs) for Electrified Powertrains

    … limitations. The SRM is tested using PWM current control as the baseline control method because hysteresis control is proven to be challenging for the tested SRM. The work presents many challenges associated with the testing and characterization of SRMs for propulsion applications; however, new …

    mcmaster Repository record for Dynamometer Testing and Characterization of Switched Reluctance Motors (SRMs) for Electrified Powertrains (opens in a new tab)

  15. Control and Modulation Techniques for the Five-Phase Coupled Inductor Inverter

    … and fast switching semiconductors complicate the control strategies, the advantages of multiphase multilevel inverters are considerable: the voltage and current rating on the semiconductors are reduced, fault tolerance is realized without extra hardware and harmonic spectrum is improved compared …

    unsw Repository record for Control and Modulation Techniques for the Five-Phase Coupled Inductor Inverter (opens in a new tab)

  16. A two-layer capacitor-based power management system for a stack of microbial fuel cells

    … to evaluate the PMS in long-term operation. To control the frequency, accuracy, and robustness of the PMS and avoid potential losses, a hysteresis control method, a simple moving average approach and a cooldown timer have been implemented. These additional control methods help the PMS to adjust …

    ets-quebec Download PDF for A two-layer capacitor-based power management system for a stack of microbial fuel cells (opens in a new tab)

  17. A power management system for isolated operation of microbial fuel cells with voltage protection

    … energy from the MFCs in the stack. The PMS controls the connection and disconnection of the MFCs such that each MFC operates independently. Consequently, should there be an MFC failure leading to unwanted MFC disconnection, the energy harvesting process from the other MFC(s) continues …

    ets-quebec Download PDF for A power management system for isolated operation of microbial fuel cells with voltage protection (opens in a new tab)

  18. Fast response controller for a stepping inductance based voltage regulator module

    … However, the scheme proposed in literature to control the SI-VRM has shortcomings. In this thesis, a control scheme is proposed for the SI-VRM which can achieve fast transient response, smooth transition between different operating states and low ripple voltage both under normal and inductor …

    nus Repository record for Fast response controller for a stepping inductance based voltage regulator module (opens in a new tab) Download file for Fast response controller for a stepping inductance based voltage regulator module (opens in a new tab)

  19. Direct Power Control of AC Motors

    In this thesis, the possibilities of direct power control (DPC) of induction motors (IMs) and permanent magnet synchronous motors (PMSMs) fed by a voltage source inverter have been studied. Three different approaches of DPC for IMs and one for PMSMs are proposed and investigated. They are: (a) …

    unr Repository record for Direct Power Control of AC Motors (opens in a new tab)

  20. A series-stacked power delivery architecture with isolated converters for energy efficient data centers

    … system for a four-server rack is created. A control algorithm is developed for server to virtual bus differential power processing and the proposed solution is also supported with experimental results. This thesis presents an experimental demonstration of a series stacked server power …

    uiuc Repository record for A series-stacked power delivery architecture with isolated converters for energy efficient data centers (opens in a new tab)

Page 1 of 2