Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"ideal observer"”.
-
The Benevolent Ideal Observer Theory
… this theory the response-dependent benevolent ideal observer theory or BIORD.</p><p>Although the way in which I express and argue for BIORD is original and unique, the core of the theory is old. In chapter 1, I explore these historical roots. The notion that moral value depends, in some sense, …
-
Approximating Ideal-Observer Performance Using Fisher Information and the Extreme Value Distribution in Detection Tasks
… is to compute the performance of the Bayesian ideal observer. An observer's performance can be illustrated by its receiver operating characteristic (ROC) curve. The area under the ROC curve (AUC) can be used as the figure of merit. The ideal-observer AUC is often computationally expensive, if …
-
Testing the Bayesian brain hypothesis in visual perception
Bayesian ideal observer theory describes perception as an ideal integration of sensory information with prior knowledge to produce optimal responses. Bayesian ideal perception models are popular in sensory domains; however, these models often prove unfalsifiable because of excessive distributional …
-
Signal detection with random backgrounds and random signals
… computational methods to investigate Bayesian ideal observers for performing signal-detection tasks. Object models are used to take into account object variability in image backgrounds and signals for the detection tasks. In particular, lumpy backgrounds (LBs) and Gaussian signals are used for …
-
Factors influencing lesion detection in medical imaging.
… for system design and optimization. The ideal observer is often chosen as a standard of comparison for the human observer since, at least for simple tasks, its performance can be readily calculated using statistical decision theory. We already know, however, of cases reported in the …
-
Signal detection in medical imaging
… algorithm will perform when mathematical observers for tumor detection use the resulting images. Here the mathematical observer is the ideal observer, which sets an upper limit to the performance as measured by the Bayesian risk or receiver operating characteristic analysis. This …
-
Assessing and Optimizing Pinhole SPECT Imaging Systems for Detection Tasks
… stochastic object using the Bayesian ideal observer. Out of all possible observers (human or otherwise) the ideal observer sets the absolute upper bound for detection task performance by using all possible information in the image data. By employing a stochastic object model we can …
-
Skepticism, reason, and decision
… the history of philosophy: Kant's refutation of idealism. In this project I propose a more plausible interpretation of Kant's argument against idealism. Next, the second project investigates ethical theory: the ideal observer view. There, I criticize an argument for ideal observer view as …
-
Objective Assessment Methods for List Mode Imaging System
… of a medical imaging system, both the task and observer have to be well defined. The objective quality of the image depends on how well the specified observer can extract the desired information to perform the task. Classification or detection tasks are often considered in practice. Two commonly …
-
Optimal Decision Making Models in Changing Environments
… of adaptive decision making. We develop new ideal observer -- Bayes-optimal -- models for this latter setting; and more specifically for the case in which temporal integration of noisy evidence improves choice accuracy. The generative model of the stimulus is a Hidden Markov Model that the …
-
Computational Mechanisms Underlying Perception Of Visual Motion
… stimuli is compared to performance of an ideal observer model. The ideal observer model utilizes computations that have been optimized for discriminating speed among a large training set of naturalistic stimuli. Although human performance falls short of ideal observer performance because …
-
Visual target detection under multiple dimensions of uncertainty
… 0.5 and 0.2. I simulated and tested three model observers. The ideal observer, which has a dynamic decision criterion, can be approximated with a contrast normalized template-matching (NTM) observer with a single criterion. Maximum-likelihood fits revealed that the NTM and the …
-
VISUAL PERCEPTION IN CORRELATED NOISE (MODELS).
This dissertation concerns the ability of human observers to perform detection tasks in medical images that contain structured noise. We shall show that physical measures of image quality, such as signal-to-noise ratio (SNR), resolution, modulation transfer function (MTF), and contrast, do not …
-
Information theoretic design of breast sonography
… on breast cancer diagnosis and is based on the ideal observer concept for visual discrimination tasks, whereby tasks based on five clinical features are expressed mathematically as likelihood functions. Realistic approximations to the ideal strategy for each task are proposed as an additional …
-
AN INVESTIGATION OF MULTIPLE-DIGIT CUE COMBINATION: PSYCHOPHYSICS AND BAYESIAN MODELING
… Bayesian inference. According to the Bayesian ideal observer model, the observer combines cues from multiple sensory streams as a weighted average based on each cue’s reliability. Most cue-combination research has focused on integration of cues between sensory modalities or within the visual …
-
Peter Railton's moral realism
… his arguments for instrumental rationality, ideal observer theory, internalism, justification of morality and his objections to non-cognitivism.
-
The leaf identification problem : natural scene statistics and human performance
… task, it is important to consider designs for an ideal observer, a theoretical system that solves a perception task in an optimal way given specific constraints. I studied three specific classification tasks related to the problem of identifying and segmenting leaves in foliage-rich images. In …
-
Objective assessment of sonographic quality for breast cancer imaging
… lowest cost and risk to patients and society. Ideally, medical imaging systems are designed by maximizing the benefit-to-cost ratio from a set of laboratory measurements that define ""image quality"" in the sense that they predict diagnostic performance in clinical applications. For ionizing …
-
A Computational Model for Predicting Visual Acuity from Wavefront Aberration Measurements
… matching algorithm. This simulation describes an ideal observer limited by optics, neural filtering, and neural noise. Experimental data in this analysis were the eye’s visual acuity (VA) and 15 modes of Zernike aberration coefficients obtained from 3 to 6 year old children (N=20; mean age= 4.2; …
Page 1 of 3