Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 76 for “"impedance analyzer"”.

  1. Design and Implementation of a Magnitude Only Bio-Impedance Analyzer

    The increasing interest in the bio-impedance analysis in various fields has increased the demand for portable and low-cost impedance analyzers that can be used in the field. Simplifying the hardware is crucial to maintaining low-cost and portability, but this is not an easy task due to the need for …

    calgary Repository record for Design and Implementation of a Magnitude Only Bio-Impedance Analyzer (opens in a new tab)

  2. Adaptation and Application of A State-Of-The-Art Impedance analyzer for Characterization of Silicon P-I-N Diodes

    Impedance spectroscopy is a powerful non-destructive characterisation technique that studies the response of samples to alternating current (AC) excitations. From a model based analysis of the impedance measurement, information on the sample under test such as dielectric constant, layer thickness, …

    nus Repository record for Adaptation and Application of A State-Of-The-Art Impedance analyzer for Characterization of Silicon P-I-N Diodes (opens in a new tab) Download file for Adaptation and Application of A State-Of-The-Art Impedance analyzer for Characterization of Silicon P-I-N Diodes (opens in a new tab)

  3. The Effect of Accurate Categorical Activity Selection on the Prediction of Percent Body Fat When Using the Omron HBF-306 Bioelectric Impedance Analyzer

    … and fitness levels in individuals. Bioelectric Impedance Analysis has become a popular field method for assessing body composition because it is inexpensive, noninvasive, and easy to administer. The purpose of this study was to compare the activity level settings (Normal vs. Athlete) on the …

    eiu Repository record for The Effect of Accurate Categorical Activity Selection on the Prediction of Percent Body Fat When Using the Omron HBF-306 Bioelectric Impedance Analyzer (opens in a new tab)

  4. Rapid reading for passive wireless coupled sensors

    … passive sensors. While the current method of impedance analyzer is sensitive and an accurate, the instruments used are bulky and slow, substantially hampering in-field testing and interrogation of sensors. Current methods cannot provide a quantifiable measure on minimum necessary read-speeds …

    texas Repository record for Rapid reading for passive wireless coupled sensors (opens in a new tab)

  5. Integration of Electrical Impedance Spectroscopy for Multichannel Cell Culture Measurement

    ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY (EIS) has been widely used to study the electrical properties of biological material due to its non-invasive nature and experimental reliability. However, most of the precision impedance analyzers used in EIS only provide single- or two-channel measurements …

    calpoly Repository record for Integration of Electrical Impedance Spectroscopy for Multichannel Cell Culture Measurement (opens in a new tab)

  6. Considerations of the Impedance Method, Wave Propagation, and Wireless Systems for Structural Health Monitoring

    … presented in this thesis is all based on the impedance method for structural health monitoring. The impedance method is an electro-mechanical technique which utilizes a single piezoelectric transducer as both a sensor and actuator. Due to the high frequencies of excitation used for the method, …

    vt Repository record for Considerations of the Impedance Method, Wave Propagation, and Wireless Systems for Structural Health Monitoring (opens in a new tab)

  7. Flexible low-cost wireless temperature sensor using thermoresponsive Y5V capacitor chips

    … MHz at room temperature. Moreover, a low-cost impedance analyzer is developed in this work. It consists of Raspi 3 host device and a Digilent PmodIA impedance analyzer has a low error of ~4% as compared to the Agilent network analyzer. The new analyzer is demonstrated and experimentally …

    ubc Repository record for Flexible low-cost wireless temperature sensor using thermoresponsive Y5V capacitor chips (opens in a new tab) Download PDF for Flexible low-cost wireless temperature sensor using thermoresponsive Y5V capacitor chips (opens in a new tab)

  8. Saturation Dependent Dielectric Constant Measurements of Carbonates between 1 MHz and 300 MHz

    … frequencies between 1 MHz and 300 MHz using an impedance analyzer and dielectric sample holder. Matlab programs were written and utilized to automate the data gathering process and calculate the dielectric constant from the reflection coefficient measurements using the short and open technique. …

    houston Repository record for Saturation Dependent Dielectric Constant Measurements of Carbonates between 1 MHz and 300 MHz (opens in a new tab)

  9. Giant Magneto-impedance Effect In Thin Film Layered Structures

    Recently, the giant magneto impedance (GMI) effect has been studied extensively because of its potential applications in sensor elements. The focus of this thesis work is to explore different compositions and processing conditions for CoSiB and NiFe thin films to obtain the soft magnetic properties …

    ucf Repository record for Giant Magneto-impedance Effect In Thin Film Layered Structures (opens in a new tab)

  10. Vertical Electrical Impedance Measurements of Concrete Bridge Decks

    … of a nondestructive vertical electrical impedance (VEI) bridge deck assessment apparatus. A multichannel impedance analyzer with a moving platform is developed that can assess the deterioration state of a bridge deck without stationary traffic control. The multichannel apparatus is …

    byu Repository record for Vertical Electrical Impedance Measurements of Concrete Bridge Decks (opens in a new tab) Download PDF for Vertical Electrical Impedance Measurements of Concrete Bridge Decks (opens in a new tab)

  11. Moisture content and bulk density prediction using dielectric properties for switchgrass and corn stover

    … 0.1 to 10 MHz were obtained using an HP 4192A impedance analyzer for switchgrass and corn stover. For each material, the measurements were obtained at four moisture content levels and three bulk densities. Dielectric properties of these materials could be calculated based on admittance readings …

    iastate Repository record for Moisture content and bulk density prediction using dielectric properties for switchgrass and corn stover (opens in a new tab)

  12. Moisture Sensing in Baled Crops

    … probe is subsequently connected to a Keysight impedance analyzer to measure dielectric properties of raw cotton at controlled levels of moisture content, compressed densities, and source frequency sweeps. Sensitivity to compositional differences such as turnout (lint vs seed) and variety is …

    iastate Repository record for Moisture Sensing in Baled Crops (opens in a new tab)

  13. Towards a Self-Powered Structural Health Monitoring Smart Tire

    … the potential of embedding sensors. The use of impedance based SHM on a tire is severely limited due to the low stiffness and high damping characteristics of the tire. This work propose the use of a high voltage impedance analyzer, and the addition of electrical circuit to enhance the damage …

    vt Repository record for Towards a Self-Powered Structural Health Monitoring Smart Tire (opens in a new tab)

  14. Electrical characterization of phytoplankton suspensions using impedance spectroscopy.

    … suspended in a stagnant medium and measured the impedance response using a lab-on-chip and impedance analyzer. The individual cell characteristics were derived from the impedance response of the group. The goal was to characterize and differentiate between algae species, as well as healthy and …

    louisville Repository record for Electrical characterization of phytoplankton suspensions using impedance spectroscopy. (opens in a new tab)

  15. The application of piezoceramic bender elements to the laboratory measurement of elastic wave velocities

    … benders that are detailed include the use of an impedance analyzer to monitor changes in the electrical and mechanical response. Placing the benders in a bucket of sand demonstrated the short compact nature of the bender waveform in both a shear and compressional wave orientation. An experiment …

    ubc Repository record for The application of piezoceramic bender elements to the laboratory measurement of elastic wave velocities (opens in a new tab) Download PDF for The application of piezoceramic bender elements to the laboratory measurement of elastic wave velocities (opens in a new tab)

  16. Fabrication and characterisation of plastics with magnetic and electrical properties

    … of the composites are characterized using an impedance analyzer. The characterization data from the experiment show that the conductivity and magnetic properties of the pure PLA is improved by combining it with carbon and iron particles. Furthermore, it is observed that, at a certain weight …

    manitoba Repository record for Fabrication and characterisation of plastics with magnetic and electrical properties (opens in a new tab)

  17. Salinity (Conductivity) Sensor Based on Parallel Plate Capacitors

    … for use as the insulation layer for the sensor. Impedance analysis performed on the two coatings using Agilent's 4924A Precision Impedance Analyzer served to prove that ACCUFLO was a better dielectric material for this application when compared to AZ5214.Two separate detection circuits have been …

    usf Repository record for Salinity (Conductivity) Sensor Based on Parallel Plate Capacitors (opens in a new tab)

  18. A Comparison of Two Methods of Body Composition Assessment in Prepubescent Males and Females

    … of body fat predicted from the bioelectrical impedance method was compared with the percentage of body fat predicted from skinfold measurements. It was hypothesized that there would be no difference between the RJL System's BIA 101 Impedance Analyzer and skinfolds in determining body fat …

    northern-iowa Repository record for A Comparison of Two Methods of Body Composition Assessment in Prepubescent Males and Females (opens in a new tab)

  19. Developing a Self-Powered, Wireless Damage Detection System for Structural Health Monitoring Applications

    … monitoring (SHM) system capable of performing impedance-based testing and detecting shifts in resonant frequencies. This independent structural health monitoring system incorporates a low power wireless transmitter that sends a warning signal when damage is detected in a structure. Two damage …

    vt Repository record for Developing a Self-Powered, Wireless Damage Detection System for Structural Health Monitoring Applications (opens in a new tab)

Page 1 of 4